[GSDML ] PLC [Lwr_Lmt] [Monitor Lower Enable Disable Limit] 8 [Lwr_Lmt] [Lower Limit 1 0 Value] 1 PLC -43No.EX-OMQ0015CN . -10..+10 V -10.50+10.45 V -10.45+10.50 V -5..+5 V -5.25+5.22 V -5.22+5.25 V -20..+20 mA -21.00+20.90 mA -20.90+21.00 mA 0..10 V 0.00+10.45 V +0.05+10.50 V 0..5 V 0.00+5.22 V +0.03+5.25 V 1..5 V +0.75+5.22 V +0.78+5.25 V 0..20 mA 0.00+20.90 mA +0.10+21.00 mA
Metal bowl B B B B B Dimensions B B N.C.: Gray N.O.: Black B 1/8 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 M5 x 0.8 Width across flats 17 Width across flats 17 Standard specifications Bracket mount Model Port size A B C D P E F G H1 H2 J K L L M (1) (1) (1) (1) ACG20 ACG30 ACG40 1/8, 1/4 126 87 36 60 28.5 41.5 43 30 24 5.5 3.2 1/4, 3/8 167 115 41 80 30 55 57 41 35 35
M V 1 1 [ ] 2 WH 18AWG BK 18AWG BK 9 9 2 V G 3 U U [ ] 1 RD 18AWG BK 5 5 1 U (CN3) PM PUMP 7 7 Option T1 6 6 4 4 3 3 2 2 1 1 PM PUMP 2/2 PM PUMP (CN1) 16AWG G/Y G4 [ ] V G PM 16AWG G/Y G4 [ ] G U DC Power Supply Standard BL DCPS [ ] 18AWG G/Y G2 5 5 Condenser 18AWG BK 1 1 3 3 3 3 18AWG BK 3 3 1 1 1 1 C3 (CN51) (CN1) (CN6) Compressor CM CM AC Power Board 3 1 PCB1 3 3 [ ] TH 14AWG BK 14AWG
Removal of the tube 1) KQ2 series is used for the vacuum (V) port. For this series, the tube can be removed by pushing B one part of the release button. 2) Hold down the release button while pulling out the tube.
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Spring extend or spring return, Bore sizes: 6
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CJ2 ROUND BODY CYLINDER, EE, 10MM CJ2 DBL-ACT AUTO-SW, 0.3858 lb
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
B Contact output signal 3 selected alarm Sets the alarm selected for the contact output signal 3. ---(AL.01)6 1: Default when CO02 is set to PRO1 or PRO2. 4: Default when CO23 is set to A.SEL. 2: Default when CO15 is set to SW-A or SW-B. 5: Default when CO26 is set to A.SEL. 3: Default when CO19 is set to SW-A or SW-B. 6: Default when CO29 is set to A.SEL.
Maximum current rating Voltage without load (V peak) 5.0 0 to 20 [V] 100 Peak voltage Over 20 [V] up to 30 [V] (2) Circuit (of class 2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. Grounding Warning 1. Make sure the product is grounded to ensure the noise tolerance of the controller.
Solenoid on side A 0 2 4 6 8 16 28 30 2 3 1 SV24 V +24 V for valve 5 2 SV0 V 0 V for valve Side D Side U URL http://www.smcworld.com 1 4 3 SW24 V +24 V for input (SI unit side) Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 SW0 V 0 V for input 4 Output No.
Analogue output A B C Voltage output 1 V 1.5 V (1.4 V) 5 V Current output 4 mA 6 mA (5.6 mA) 20 mA : The value in ( ) is when PF2W711 is used. Rated flow range Model Min. Max. PF2W704(T) 0.5 L/min 4 L/min PF2W720(T) 2 L/min 16 L/min PF2W740(T) 5 L/min 40 L/min PF2W711 10 L/min 100 L/min -46No.PF-OMO0012-E Revision history A: Contents revised in several places. B: Revision.
A73C A72H A73H E76A E73A F79 F7P J79 F79W 200 V Relay, PLC 2-wire 100 V 12 V Yes 24 V Connector 3-wire (NPN equivalent) IC circuit 10 5 V Grommet 2-wire 24 V Relay, PLC 100 V 12 V F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector 10 16 20 25 32 3-wire (NPN) 3-wire (PNP) 24 V IC circuit 16 20 25 32 5 V, 12 V Diagnostic
Ionizer Model number IZS31 (NPN specification) IZS31P (PNP specification) Ion generating method Corona discharge type Method of applying voltage Sensing DC, Pulse DC, DC Discharge output +/-7000 V Offset voltage *1 +/-30 V (+/-100 V for stainless steel emitter) Fluid Air (Clean dry air) Operating pressure 0. 7 MPa or less Air purge Connecting tube O.D. mm Power supply voltage 24 VDC +/-10%
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.