This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, 3 PORT LOCK OUT, VALVE, VHS HAND VALVE, KA, VHS BODY PT >3/4NPT (F), 1.91863 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FR/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, GA, AC MASS PRO 3/4 MODULAR (PT), 3.84771 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureSet pressure rangeRelief pressureNominal filtration ratingRecommended
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, GA, AC MASS PRO 3/4 MODULAR (PT), 10.14126 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, 3 PORT LOCK OUT, VALVE, VHS HAND VALVE, KA, VHS BODY PT >3/4NPT (F), 1.69755 lb
Series PA is a double acting, compact, large capacity diaphragm pump suitable for transfer and recovery of a wide variety of fluids. The PA series is available in 3 types; automatically operated, air operated or automatically operated with a built-in pulsation attenuator. Air pilot type process pump, Discharge rate 5 to 45 /min, Compact, large capacity, Easy maintenance due to structural
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 1.76369 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 2.86600 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Operating fluid temperatureLinearityRepeatabilityTemperature
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 1.87392 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Operating fluid temperatureLinearityRepeatabilityTemperature
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient & fluid temperature: 0 to 60°C, Electrical entry: grommet,
SMC's newest micro mist separator, series AFD is available in 3 sizes; 1/4 (20), 3/8 (30) & 1/2 (40). Rc(PT), PF & NPT threads are available. Port sizes range from 1/8 to 3/4. Body size 30 and 40 now have a transparent bowl guard that offers 360° visibility, while completely protecting the bowl from the environment. Accessories include a bracket, and float type auto drain., MICRO MIST
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 2.09439 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Operating fluid temperatureLinearityRepeatabilityTemperature
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 1.70434 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Operating fluid temperatureLinearityRepeatabilityTemperature
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GX, IFW/PFW 3/4INCH ALL OTHERS, 1.25663 lb, ModelMeasured fluidFlow rate measurement rangeSet flow rate rangeRated flow rangeMinimum set unitAccumulated pulse flow rate exchange value (Pulse width: 50 ms)Operating fluid temperatureLinearityRepeatabilityTemperature