BH BI (UU) 2-M3 x 0.5 (opposite side, same location) (For front port, use hexagon socket head set screw) Q H 2-J through JA depth of counter bore JB (opposite side, same location) 1.5 S BE CA CB BF DD D BD BG A 2.2 (0.4) Note 1) SD 16 BA 2-M3 x 0.5 depth 4 BB W 2-M3 x 0.5 (For side port, use hexagon socket head set screw) N BC Note 2) For the 180 specification, the slated line area do not

Do not use the product for flammable fluid. Fire or explosion can result. Only air, N2, are applicable. Flow direction: Left Right Flow direction: Right Left Default setting Rotation of the display Function (Main display) Do not use the product in a place where static electricity is a problem.

Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction or damage to the product can result. Verify the specifications before use. S S S Flow direction (1) Press the SET button once when the item to be changed is displayed on the display. The set value on the sub display (right) will start flashing.

Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) [F20] Setting of external input Accumulated flow external reset [F22] Setting of analogue output Free range analogue output for instantaneous flow: OFF * Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Do not operate in locations with an atmosphere of corrosive gases, chemicals, sea water, water or steam, or where the same substances will adhere to the regulator. 2. Do not operate in locations where vibration or impact occurs. 3. In locations under direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off the radiated heat. 5.

Connection Be sure that chips from the pipe threads and sealing material do not get inside the piping. Further, when sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of male threads. Do not use with gases. 4.

Do not press this button, as it can result in damage to the product.

Connection Be sure that chips from the pipe threads and sealing material do not get inside the piping. Further, when sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of male threads. Do not use with gases. 4.

Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Specifications x100 IP address x 10 1 DIP SW Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

Specifications Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Technical documentation giving detailed configuration information and the GSD file can be found on the SMC website (URL http://www.smcworld.com). Specifications Do not operate in an atmosphere containing flammable or explosive gases.

Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Connect valve manifold to the SI unit. Refer to the EX260 series valve manifold section in the valve catalogue for valve manifold dimensions. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Tidy Un-friendly What do you think to the manual presentation? ! ! ! Yes Not too bad Unusable Are the explanations understandable? Which explanation was most difcult to understand: . . ! ! Are there any diagrams which are not clear? Yes No If so,which:. ! ! ! What do you think to the manual layout?

Safety lock (released) 87 171 Note) Do not use it to cut the metalic materials such as electric wires.

Installation location Do not install this product in an area that is exposed to rainwater or direct sunlight. Do not install in locations influenced by vibrations. If it must be used in such an area due to unavoidable circumstances, please contact SMC beforehand. 7 Booster Regulator Series VBA Handling Caution 3.

Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.

Bit: 7 0 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bit No. 6 4 6 4 2 0 0 0 Solenoid on side A 0 2 4 6 8 16 28 30 Output No.

Note 2) Use a bushing (part no: 131368) when connecting R 1/8 pressure gauge to R 1/16 gauge port. Note 3) Not applicable to AW10. Accessory part no.

Note 1) Do not use the product in an atmosphere and place where there is direct contact with chemicals. It may cause damage to the body. (Alcohol, acetone, etc. also cause damage, so be sure for the product not to be close to them.) Note 2) Do not use it in a line that is kept pressurized because it could cause the body to break.