Thomas Liquid Diaphragm Pump Flow Rate: 400 ml / min , 400 ml / min, Max Pressure: 15 m H20 , 15 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: .41 lbs. / .19 Kg Series Configured Datasheet.
Thomas Liquid Diaphragm Pump Flow Rate: 400 ml / min , 400 ml / min, Max Pressure: 15 m H20 , 15 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 12, DC Motor Type: Standard, Net Weight: .41 lbs. / .19 Kg Series Configured Datasheet.
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)14.1 scfm (400 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
C)44 to 145psi (0.3 to 1.0 MPa)59 to 86F (15 to 35?C) (Relative humidity 85% or less)59 to 86F (15 to 30?C)22 to 123psi (0.15 to 0.85 MPa)(The inlet air pressure should be at least 22psi (0.15 MPa) higher than the outlet air pressure.)21.2 scfm (600 L/min [ANR])102psi (0.7 MPa)95F (35?C)86F (30?C)86F (30?C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?
CH4 CH3 Pressure value for each channel are displayed at 2-second intervals. 15 16 Series PSE Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of "Caution", "Warning" or "Danger".
DC() IN (1 to 5 V) Analog output or auto shift input Gray 2 DC(-) Blue 1 20 2 m 20 With bracket A 30 20 46 4.2 10 15 40 31.5 26.5 1.6 7.2 22 35 41 A View ZS-28-B Bracket With panel mount adapter With panel mount adapter + Front protective cover 42.4 34.5 24 7 34.5 24 11 Panel thickness 0.5 to 6 ZS-27-D Panel mount adapter + Front protective cover 8.75 ZS-27-C Panel mount adapter 6 Series
(Refer to Best Pneumatics Vol. 15.) Accessory (Option)/Part No. Part no. Description ARJM10-4, -6, -10 Manifold base ARJ1020F-M5-06 ARJ1020F-M5-04 How to Order M5 ARJ 20 10 F 04 1 Option 1 0.2 MPa setting Miniature regulator Note 1) Compared with standard specifications, its adjusting spring has only been changed.
15 Precautions Be sure to read before handling.
A 15 g piece of fluororesin tubing is cut off, washed in deionized water and immersed in 15 ml of 25% methyl alcohol extract at room temperature for 24 hours. Then the extract is diluted with deionized water to be subjected to a quantitative analysis of fluorine ions. The interior of the fluororesin tubing is washed with super deionized water.
-25A VND50D-32A VND50D-32F VND60D-40A VND60D-40F VND70D-50A VND70D-50F 1 8 1 4 26 28 31 120 130 240 380 7 0.3 3 8 15 0.6 1 2 3 4 20 0.9 1.4 2.3 5.5 3.6 7.2 5.7 10.8 25 1 VC 1 4 1 440 32 32 1 2 1 VDW 920 40 40 2 VQ 1500 50 50 Note) The companion flange is JIS B 2210 10K (standard) or its equivalent.
VC Pilot air Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5.5 MPa 10.5 MPa Proof pressure Ambient temperature Max. operating frequency Mounting position Port size Orifice size (mm) Flow characteristics Av x 10-5 VDW 5 to 50C 20 times/min Vertical upwards VQ Rc 1 2 Rc 3 8 Rc 3 4 Rc1 Rc 3 8 Rc 1 2 Rc 3 4 Rc1 Rc 3 8 Rc 1 2 Rc 3 4 Rc1 VX2 7.1 86 8.7 110 10.6 190 14.3 15
Refer to pages 13-15-3 to 13-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to page 13-1-5 for Precautions on every series. Mounting Operating Environment Caution Warning 1. Air piping should be thoroughly flushed before mounting. 2.
Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation
Note 2) Set the tightening torque of a hexagon socket head set screw (M4 0.7) to be 1 to 1.2 Nm. * To protect auto switches, ensure that main body of an auto switch should be embedded into auto switch mounting groove with a depth of 15 mm or more. Auto Switch Mounting Bracket Part No.
Namur mounting allows for installation between the Actuator and SMC PPS Body Solenoid Valve or on a Delrin Sub-base 41 23.5 3. Will help reduce "water hammer" by throttling the actuator speed allowing for more precise Actuator control 2xDUCK-BILL CHECK VALVE (3/5 PORT) 4. Stainless Steel adjustment screws PORT 1 PORT 3 5.