SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-41-10-M5"

1 Auto Switch Guide Reed Switches/Solid State Switches For Rotary Actuators (Air Grippers) Applicable Auto Switch Auto switch mounting Applicable air grippers Applicable rotary actuators Auto switch model Electrical entry Page Type CRB2 Size Size CRBU2 30 50-100 10/15 20-40 10-40 32/40 1/3 7/20 10-200 05/1 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB2 CDRBU2 CDRQ2MRQ

ZH13DL-08-02-10 14.2 S type: White color L type: Black color 14.2 Applicable tubing diameter N ZF 14.2 Applicable tubing diameter E 14.2 17.2 ZP 17.2 19.95 ZCU 19.95 93.3 58.5 41 10 15.3 4.2 19 ZH15DS-10-03-12 22.45 AMJ 93.3 58.5 41 10 15.3 4.2 19 ZH15DL-10-03-12 22.45 (Mounting hole) Model I J K L M N O P Misc.

HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB

1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB

KFN-04 KFN-06 KFW-04 KFW-06 KFV-04 KFV-06 KFS-04 KFS-06 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.

Mode . 40 9.1 Outline . 40 9.2 Step No. instructions operation function . 40 2 - 9.3 Position / speed monitor . 41 9.4 Operation by numerical instruction . 41 9.5 Data editing function . 42 10. Memory map . 45 10.1 Remote IO (Rx and Ry) . 45 10.2 Remote register (RWr and RWw) . 51 11.

/N.O. 1/8 to 1/2 2 to 10 10 to 50 N.C.

11 14 20 20 27 16 19 24 34 34 42 40 50 64 80 80 10 10 14 22 22 25 10 10 14 22 22 25 14 14 20 30 30 32 14 14 20 30 30 32 28 28 40 60 60 64 12.5 16.5 23.5 23.5 100 119 28.5 Combinations of Support Brackets Available combinations Refer to below picture together.

0.0 5 0 10 20 30 5 0 10 20 30 Circulating fluid flow[L/min] Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS040--20-(BJM)) 9.6.2 HRS040--20-T,-MT 0.5 50 Available area 0.4 40 Circulating fluid pressure[MPa] Pump head[m] Outlet50Hz Outlet:60Hz 0.3 30 0.2 20 0.1 10 Return port Available area 0 0.0 0 10 20 30 40 Circulating fluid flow[L/min] Fig. 9-8 Pump capacity(HRS040--20-T/-MT)

20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig. 9-4 Cooling capacity(HRS050--20-(BJM)) 9.5 Heating capacity 9.5.1 HRS050-A-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 1500 1500 5 Heating capacity [W] Heating capacity [W] 5 20 20 25 25 1000 32 1000 32 40 40 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40

Refer to LECSS2-T Operation Manual,section 3.5 for input/output signal details. -10- 3.3.2 Source Sink I/O interfaces Connection example An example wiring diagram for Sink I/O is shown below Driver Servo amplifier () CN8 (Note 16) Short-circuit connector (Packed with the servo amplifier) 10 m or less driver) (Note 12) CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power

0.7 70 0.6 60 Circulating fluid pressure[MPa] 0.5 50 Pump head[m] Availavel area 0.4 40 Outlet60Hz 0.3 30 Outlet50Hz 0.2 20 0.1 10 Return port Availavel area 0.0 0 10 20 30 40 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS060--20-(BJM)) 9.7 Required facility water flow (For water-cooled type) 30 Facility water flow rate[L/min] 25 20 15 10 5 0 0 10 20 30 40 50 Facility water inlet

10 ZP20U ZPT3-7A-X2 ZP 25 U ZPG25U-7A-X2 10 10 10 11 ZP25U ZP 32 U ZPG32U-7A-X2 10 11 11 12 ZP32U ZP 10 C ZPG10C-7A-X2 7 7 7 7 ZP10C ZPT2-7A-X2 ZP 13 C ZPG13C-7A-X2 7 7 7 7 ZP13C ZP 16 C ZPG16C-7A-X2 7 7 7 8 ZP16C ZP 20 C ZPG20C-7A-X2 9 10 10 11 ZP20C ZPT3-7A-X2 ZP 25 C ZPG25C-7A-X2 10 10 10 11 ZP25C ZP 32 C ZPG32C-7A-X2 10 11 11 12 ZP32C ZP 10 B ZPG10B-7A-X2 7 7 7 8 ZP10B ZPT2-

to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 12 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.

-400 KN-10-600 KN-12-400 KN-12-600 KN-16-400 KN-16-600 KN-20-400 KN-20-600 10 10 12 12 16 16 20 20 4 6 4 6 4 6 4 6 17 17 17 17 17 17 17 17 29.5 27.7 41.3 31.2 40.1 38.4 45.6 43.9 17 17 19 19 24 24 27 27 14 14 17 17 22 22 26 26 D H2 H1 L2 L1 Nozzle with Male Thread / KN (mm) Model Nozzle diameter D Connection size L1 A With across flats H1 Connection thread KN-R02-600 KN-R03-400 KN-R03-600

(C) 55 50 60 70 80 IDU3D to 6D 45 50 55 65 75 IDU8D to 15C 45 50 55 65 70 IDU22C1, 37C1 40 45 50 55 60 IDU55C, 75C Ambient temperature (C) Outlet air pressure dew point (C) 15 10 5 15 10 5 15 10 5 15 5 10 5 15 10 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 0.60 1.35 0.60 1.35 1.35 25 1.35 1.05 0.50 1.35 1.05 0.50 1.35 1.10 0.50 1.35 0.60 1.20 0.55 1.35 1.25 30 1.25 0.95 0.45 1.25 0.95

32 Specifications 32 Dimensions 33 SI Unit Summary of Product Parts 34 Mounting and Installation 36 Installation 36 Wiring 37 Setting 41 Specifications 41 Specifications 41 Dimensions 42 Output Unit Summary of Product Parts 43 Mounting and Installation 44 Installation 44 Wiring 45 Specifications 48 Specifications 48 Dimensions 48 -1No.EX-OMI0032-G Input Unit Summary of Product Parts 49 Mounting

S 10 S 10-1 10-2 IDFB3E PE 10-1 IDFB Series 10 1 IDX-OM-W020 10 S IDFB4E 11E PE IDFB15 PE 10-2 IDFB Series 10 2 IDX-OM-W020 11 T 11 T 11-1 IEC 11-2 AC115V,5A DC24V,5A (20V,5mA(AC/DC)) 11-3 ON ON/OFF 3 () 5 /1 () 11-1 IDFB Series 11 1 IDX-OM-W020 11 T 11-4 IDFB4E 11E PE 1 2 3 : 0.25inch (6.5mm) : 0.002inch 2 (1.25mm 2) 0.003inch 2 (2mm 2) : 0.0008inch 2 (0.5 mm