Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.

fluid outlet 0.6 60 Pressure [MPa] 0.5 50 Lifting head [m] Usable flow rate range 0.4 40 0.3 30 Circulating fluid return 0.2 20 0.1 10 0 0 0 20 40 60 80 100 120 140 160 180 Circulating fluid flow[L/min] Fig. 8-11 Pump capacity(HRL300-A-20 CH1) 8.5.4 HRL-A-20CH2 0.6 60 0.5 50 Lifting head [m] Pressure [MPa] 0.4 40 Usable flow rate range Circulating fluid outlet 0.3 30 0.2 20 Chiller display

Fig. 9-22 Cooling Capacity (HRL100/200-W-40-T2 CH2) HRL Series 9.4 Cooling Capacity 9-19 HRX-OM-X037 Chapter 9 Documents 9.5 Pump Capacity 9.5.1 HRL100-A/W-40 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow [L/min] Fig.

Coil rated voltage (V) 24, 6, 12, 48 Allowable voltage fluctuation (%) Power consumption (W) [Current mA] 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200

Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.

Circulating fluid set temperature 20 READY band width (upper/lower temperature range) 2 READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.

60 85 110 80 230 250 300 480 Note 1) Not clear, but translucent due to material.

Hz) [W] 1700/1900 2500/2900 Heating capacity3 (50/60 Hz) [W] 430/540 430/540 Temperature stability5 [C] 0.1 Circulating fluid system Rated flow6, 7 (50/60 Hz) [L/min] 7 (0.13 MPa)/7 (0.18 MPa) Maximum flow rate (50/60 Hz) [L/min] 27/29 Maximum pump head (50/60 Hz) [m] 14/19 Output [W] 200 Tank capacity [L] Approx. 5 Port size Rc1/2 Pump Fluid contact material Stainless steel, Copper (Heat

(Refer to page 60.)) (3) Change the set value with or button, and press the button to set the value. Then, the setting moves to the delay time of the switch output. (The snap shot function can be used. (Refer to page 60.)) (4) Press the or button, the delay time of the switch output can be selected. Delay time setting can prevent the output from chattering.

(Refer to page 60.)) (3) Change the set value with or button, and press the button to set the value. Then, the setting moves to the delay time of the switch output. (The snap shot function can be used. (Refer to page 60.)) (4) The delay time of the switch output can be selected by pressing the or button at the ON and OFF point of the switch output.

Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. To be ready is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.

100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)

Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source IDG 90 130 0.4 0.45 1.44 1.4 50 60 0.4 0.35 55 65 0.8 0.9 38 46 132 x 2 170 x 2 0.23 0.26 50 Hz 60 Hz 50 Hz 60 Hz AMG Power consumption (W) Compact size and lightweight Uses minimal floor space Built-in drain separator

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 to 50 Indoor Three phases 200 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source 90 130 0.4 0.45 1.44 1.4 50 60

An example is shown below: Set circulating fluid temperature: 20 oC READY bandwidth (range between the upper and lower limit temperatures): 2 oC READY time: 60 seconds Preparation for operation will be completed 60 seconds after the circulating fluid temperature reaches the range of 18 oC to 22 oC. Shorter than 60 sec. 60sec.

HECR008-W HECR012-W 1 Unused BUS + 0 0 Operation temp. range 10.0 to 60.0 C (No dew condensation) 5 4 3 2 1 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 During operation or maintenance of the product, do not disable the Communication Indication temp. range -9.9 to 80.0 C 2 RXD (RD) Unused Circulating fluid temp. deg.C Circulating fluid temp. deg.C connector Temp: 10 to 35 C Humidity : 35

Port size (A port) Rated voltage Option M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Nil None With bracket (Not assembled) P, R port: M5 4 5 6 24 VDC 12 VDC F Thread type 7 240 VAC, 50/60 Hz 9 Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800

(Values at the initial period) VT325-C VT325-G JIS Symbol Solenoid Specifications Grommet, Conduit, DIN terminal, Conduit terminal 100, 200 VAC, 50/60 Hz, 24 VDC 15 to +10% of rated voltage 75 VA 60 VA 27 VA 17 VA 12 W Electrical entry Coil rated voltage Allowable voltage fluctuation 50 Hz 60 Hz 50 Hz 60 Hz Inrush AC Apparent power (3) Holding DC Power consumption (3) Note 3) At rated voltage