This circulating fluid cools parts of the customers machine that generates heat. 3.2 General Specifications HECR008-W HECR012-W 2000 Facility water temp. 10deg.C 2000 N L Cooling capacity W This symbol warns you of potential electrical shock.
Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air New Series VX21/22/23 Reduction of power consumption Reduction of power consumption (DC specification) (DC specification) 6 W 4.5 W 6 W 4.5 W 8 W 7 W 8 W 7 W 11.5 W 10.5 W 11.5 W 10.5 W Low power consumption type: Low power consumption type: 0.8 W 0.8 W (Held at 24 VDC) VX Series New VX Series now on sale!
EX510-VSS EX510-VSQ L 20 20 L 20 20 2.8 2.8 B C A How to Order EX510-V + 10 S S EX510-VWS EX510-VWQ Output Valve connector L 20 20 L 20 20 S W 1 point 2 points Nil S Q None For SY, SYJ series For VQ, VQZ series Note) Cable length (L) 2.8 2.8 10 30 1 m 3 m B C A + Note) VQ is compatible with the positive common only.
Head side trunnion style MX0 MS1 MF1 MF2 MS4 B L F G R 1.5" 2" 2.5" 3.25" 4" 150 200 250 325 400 For special rod end modifications, please see page 6-15-33.
Not available with W and K option 6-15-6 6 Series NCA1 Auto Switch Specifications Applicable Auto Switch/Refer to page 6-16-1 for further information on auto switches.
L1 A1 Mr Static moment Dynamic moment Graph (1) Load Mass: W W W MXJ4 A3 L3 L2 A2 0.10 L3 A3 Rubber stopper Mr Load mass W kg Mp 0.08 My Metal stopper W 0.06 W W 0.04 Mey Mep We 0.02 We L3 L2 A2 0.00 Collision speed V mm/s (Average speed x 1.4) 0 200 100 300 400 500 600 700 A3 MXJ6 Note) Static moment: Moment generated by gravity Dynamic moment: Moment generated by impact when colliding with
Cam Lever NVM121-NO1-02 = z-wayi 2 porl-lh" NPT w/One Way Cam Lever NVM131-N01-01 : 3-way; 2 porl:/e" NPT w/Std.
o rod boot W/ rod boot W/o rod boot W/ rod boot Bore (mm) Style Bore (mm) Stroke range (mm) S Style h H ZZ e f ZZ1 ZZ1 ZZ l 125 140 160 180 200 250 300 125 140 160 180 200 to 1000 133 110 235 75 40 0.2 Stroke 258 98 258 235 Lube Non-lube Air-hydro Lube Non-lube Air-hydro to 1000 133 235 40 110 75 0.2 Stroke 258 98 258 235 to 1200 40 141 120 256.5 75 0.2 Stroke 277.5 106 277.5 256.5 to 1200
2 x M Thread depth N 2 x M Thread depth N L L K K N.C.
Nil T Nil W Motor specification G R Y Matsushita Electric Industrial Co., Ltd.
Consult SMC for other voltages. 2.9-12 Series VQ100 Plug Lead Unit Manifold (VV3Q12) L1 10.8 3.5 5 L2 3 P E 8.9 P E 11 Round head screw M1.7 X 14 W (L type) 28.7 26.5 W (M type) 300 33.8 300 2-3.5 Mounting hole 4-M5 SY P, E port Manual override SYJ 11.5 P=10 300 Latching, 100V AC or more VK H (M type) U side D side n 5 4 3 2 1 300 H (L type) VZ VT VT 42.2 L type M type 36.3 VP W
If the leakage volume is 30 /min (ANR), the vacuum pressure of the S type is 20 kPa q w e, and for the L type it is 33 kPa q' w' e'. If the leakage volume is 5 /min (ANR), the vacuum pressure of the S type is 80 kPa r t y, and for the L type it is 47 kPa r' t' y'.
Stroke Against Lateral Load D RS H A 17 24 27 29 0.7 W W W 500 82 103 116 127 0.3 RZQ Bushing (Bearing) fR U 62 79 89 97 0.5 Lateral load applied to rod end (fR) N 100 MI W S 52 66 75 81 0.7 50 CEP1 33 43 49 53 0.3 23 31 36 39 T 0.5 10 CE1 5 18 25 29 31 0.7 REC40 REC32 REC25 REC20 CE2 Rod side flange style: F Head side flange style: G 182 167 148 118 0.3 Foot style : L 1 L ML2B 140 128 114
L (Ex.) A53L 5m . Z (Ex.)
Flange type Electrical entry Symbol Type Applicable flange size Nil 16, 25, 40, 50, 63, 80 63, 80 Grommet (lead wire length 300mm) Grommet (lead wire length 600mm) L type plug connector M type plug connector G H L M D KF(NW) K(DN) Solenoid valve direction Left flange surface K L Solenoid valve action Rear flange surface Right flange surface Nil 2 position single 2 position double M W Note
Standard type For 90 For 180 Positioning pin hole Positioning pin hole Counter-clockwise 3 3 A port A port A port 3 22.5 3 22.5 84 e 96 ng e 3 ra ng on ra ti B port n ta 3 90 tio 4 ro 7 ta m 1 Clockwise ro e e u s i g m w 3 m k n C c l o 6 ni a u 8 r Mi im n 1 3 o ti e ax ta ng ro M m u ra m ni Mi 180 n tio e C ta s l i o w c ro k m mu xi Ma Positioning pin hole Positioning pin hole Position
Unit/Specifications Air filter (w/auto-drain, w/manual drain) 5m Filtration Regulator 0.05 to 0.85MPa Set press.
Stroke Against Lateral Load D 17 24 27 29 0.7 W W W 500 82 103 116 127 0.3 Bushing (Bearing) fR U 62 79 89 97 0.5 Lateral load applied to rod end (fR) N 100 52 66 75 81 0.7 50 33 43 49 53 0.3 10 23 31 36 39 T 0.5 REC40 REC32 REC25 REC20 5 18 25 29 31 0.7 2 Rod side flange style: F Head side flange style: G 182 167 148 118 Foot style: L 0.3 1 L 140 128 114 90 0.5 0.5 W W W F REA 117 108 95
Stroke Against Lateral Load D 17 24 27 29 0.7 W W W 500 82 103 116 127 0.3 Bushing (Bearing) fR U 62 79 89 97 0.5 Lateral load applied to rod end (fR) N 100 52 66 75 81 0.7 50 33 43 49 53 0.3 10 23 31 36 39 T 0.5 REC40 REC32 REC25 REC20 5 18 25 29 31 0.7 2 Rod side flange style: F Head side flange style: G 182 167 148 118 Foot style: L 0.3 1 L 140 128 114 90 0.5 0.5 W W W F REA 117 108 95