Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10
A B 10 20 20 40 B B B 25 45 A A 30 55 Detection hole Detection hole 40 65 50 75 Electrified object Electrified object 60 90 70 100 75 105 (2) After installation, confirm if electrified potential is correctly measured. (Unit: mm) Detected value of electrified potential depends on ambient installation conditions. Confirm detection condition of sensor electrified potential.
A O OUT 2 I N 1 SMC A J A IN OUT H G M Parts list Material Note Description No.
It is an assembly of a piston and a gasket (KSYP-13).
Cable color Terminal no A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 8 8m *1) B A-2 Yellow 5 COM-A / COM B-3 Green 3 A 10m *1) COM-B / A-3 Bule 4 B 15m *1) Shield Cable color Terminal no C 20m *1) Vcc B-4 Brown 12 GND A-4 Black 13 A B-5 Red 7 A A-5 Black 6 *1) Produced upon receipt of order. B B-6 Orenge 9 Only Robotic type cable can be B A-6 Black 8 3 selected.
KK KK EA MM MM B B E/2 4-NT ND Deep SN + Stroke (A + B) Stroke B Stroke A G C A TN C G A E XT XT LD + Stroke (A + B) WF WF ZZ + Stroke (A + B) (in) ZZ PC KK Y R XT G A LD Bore (in) DD C NT ND AA EA D B MM WF P K E SN TN EE 9.44 1.30 7/16-20 1.71 1.43 1 15/16 1.26 3/4 7.44 150 (1.5") 1/4-28 3/8 1/4-20 9/32 2.02 0.3 9/16 1 1/8 5/8 1 2.36 9/32 2 5.56 5/8 3/8 9.52 1.30 7/16-20 1.71 1.84 1 15
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
wire length L0: 600 mm L1: 1500 mm U side 3.5 163 L2: 3000 mm 44 62 73 Station number 9 9 2-Rc 1/8 (External pilot port) Electrical entry on U side (LU) 15 12 X n Manual override 2 B 4 A 8 2 B 4 A B A B A B A B A B A A A 7 SMC SMC SMC SMC SMC SMC SMC B B B A A A A A A A Indicator light 2 B 4 A 6 2 B 4 A 5 L2 L1 2 B 4 A 4 B B 2 B 4 A 3 2 B 4 A 2 50.5 P = 25 P = 25 2 B 4 A 1 44 12 X Stations
B A B A B A PB PB Double acting N.C. N.O. N.O. Double acting Double acting With flow rate adjustment PA PA B A PB B A N.C. Double acting With bypass PA PA N.C. PB B A B A Double acting N.C. Double acting With flow rate adjustment & by-pass PA PA N.C. B A PB B A Double acting N.C. Double acting With indicator PA N.C. B A N.C. Manifold (5 stations max.)
A E Push type A Push-locking type E Dimensions: Single Dimensions: VZ1120-G-M5-X1 Push type A (Push type A) Manual override Manual override (Non-locking) (Mounting hole for manifold) Push-locking type E (Piping port) Manual override (Push-locking type E) ( ) Pressing makes the valve operate.
Note 3) Do not use this product in a manner in which the tube is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fitting. A material change over a long duration or due to high-temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
It is recommended for future piping expansion that all piping ends should terminate with a T joint with plugs.
LVC B A B A B A PB Double acting N.C. N.O. Double acting LVA With flow rate adjustment PA PA N.C. B A PB B A Double acting LVH N.C. Double acting With bypass PA PA N.C. LVD PB B A B A Double acting N.C. Double acting With flow rate adjustment & bypass LVQ PA PA N.C. PB B A B A Double acting N.C. Double acting LQ1 With indicator PA N.C. B A LVN N.C.
are used 200 200 When 20 units are used Approx. 100% reduction Current model IR3000 Series Approx. 100% reduction 49000 yen reduction 150 150 128000 yen reduction Current model IR1000 Series IR2000 Series 100 100 IR1200-A Series IR2200-A Series 50 50 IR3200-A Series 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Units used Units used Bleed air 0 IR No fixed throttle in the new design.
With functions narrowed down, 2 independent temperature control systems have been achieved with only a single compressor , a single pump , and a single tank .
Never mount a product in a location that will be used as a foothold. The product may be damaged if excessive force is applied by stepping or climbing onto it. Do not use this cylinder as a stopper. Minimum adjusting stroke necessary for a positioning stop is 5mm. Operate for 5mm or more before a positioning stop. Ex: 1.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
: One-touch fitting 1(P): Male thread 2(A): One-touch fitting 1(P): One-touch fitting 2(A): Male thread 1(P): Male thread 2(A): Male thread 2(A) 2(A) 2(A) 2(A) Applicable tubing O.D.