SMC Corporation of America
Elite Part Number Search
Search Results "CDLG1GA32TN-125-D-M9PSAPC-C"

Magnet: D (Built-in), Mounting: C (Rear Clevis), Overall Length: Z (Super Compact), Bore Size: 150 (1 1/2"), Stroke: 125 (1 1/4"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Cylinder Inner Diameter: D(φ): 20, Stroke: L(mm): 125, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None,

Cylinder Inner Diameter: D(φ): 25, Stroke: L(mm): 125, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None, Body Options: Basic Integrated

Cylinder Inner Diameter: D(φ): 20, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder Inner Diameter: D(φ): 25, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder Inner Diameter: D(φ): 50, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number

Cylinder Inner Diameter: D(φ): 63, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.12~1.0, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto Switches: Without

Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 50, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 63, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 80, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 100, Stroke: L(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead

Cylinder Inner Diameter: D(φ): 125, Stroke: L(mm): 320, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet

Cylinder Inner Diameter: D(φ): 125, Stroke: L(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 125 (1 1/4"), Stroke: 0100 (1"), Cushion: C (Rubber Bumper), Rod Boot: J (Nylon)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 125 (1 1/4"), Stroke: 0100 (1"), Cushion: C (Rubber Bumper), Rod Boot: K (Neoprene)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 125 (1 1/4"), Stroke: 0150 (1 1/2"), Cushion: C (Rubber Bumper), Rod Boot: J (Nylon)