Body Size: 4 (1/2 Basis), Control Method: 1 (Meter-in), Thread: F [G(PF)], Port Size: 04 (1/2), Sealant: S (Sealant)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V)
Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 40 (5~40 l/min), Thread: F (G thread), Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 40 (5~40 l/min), Thread: F (G thread), Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 40 (5~40 l/min), Thread: F (G thread), Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Body Size: 450C [78SCFM (2,200l/Min), Approx. Compressor Output 15HP, (11kW)], Thread: F (G), Port Size: 04 (1/2), Accessory: None, Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: F (Fluororubber)