SMC Corporation of America
Elite Part Number Search
Search Results "AC60B-10-D"

Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers.

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

Product Outline . 6 2.1 Product features . 6 2.2 Product configuration . 7 2.3 How to Order . 8 2.4 Option . 9 (1) Actuator cable (5m or less) . 9 (2) Actuator cable (8-20m) . 9 (3) Actuator cable for with lock and sensor (5m or less) . 10 (4) Actuator cable for with lock and sensor (8-20m) . 10 (5) I/O Cable . 11 (6) Controller setting kit . 11 (7) Teaching box . 12 2.5 Startup Procedures

) 5, 10, 20, 40 74, 105 EM100 All types of gases/liquids, High-temperature fluids P.42 5, 10, 20, 40 74, 105 EM500 Stainless steel 316 21 Filter Selection by Main Application FGD/FGE/FGG type FGD type FGE type FGG type Applications and Applicable Element : Recommended : Can be used : Cannot be used Applicable filter model F G D C F G D E F G D T F G D F F G E S F G E L F G E T F G G S F G

) (Different surfaces and same surfaces) 65 70 10 55 60 D-M9V-900 1 D-M9WV-900 55 30 (n 4 65 30 (n 4 60 30 (n 4 70 30 (n 4 10 30 (n n=(4,8,12,16) n n=(4,8,12,16) n=(4,8,12,16) n=(4,8,12,16) n=(2,4,6,8) 15 Auto switch Connection and Example 16 3.

or less Max 150mA 5~28VDC 1.5V Max ON: Red LED D-S992L D-S991L 2 Wire Solid State 10~28 VDC 5~150mA 4V Max ON: Red LED D-T992L D-T991L Reed 24VDC; 100VAC 5~40mA; 5~20mA Max2.4V ON: Red LED NCRB1BW20 D-R732L D-R731L Reed 24VDC/AC or less; 100VDC/AC Max 50mA; Max 20mA 5~28VDC None NCRB1BW30 D-R802L D-R801L 3 Wire Solid State NPN 28VDC or less Max 150mA 0.8V Max ON: Red LED D-S792L D-S791L

-Example of when the stroke is 10 mmToward the connector Away from the connector side side 0 (Origin position) 10 d) Positioning time Set the time required to reach the [Target position] from the current table position. The setting range is 0 to 60 seconds. The positioning control is not performed when the positioning time is set to 0.

D-M9B, D-F8B D-M9N, D-F8N 2-wire 3-wire 24 VDC relay, PLC 24 VDC relay, PLC Solid state auto switch Yes 24 VDC (10 to 28 VDC) 24 VDC (4.5 to 28 VDC) Yes 2.5 to 40 mA 40 mA or less Refer to page 920 for the applicable auto switch list. 909 Rotary Table MSQ 1122Specifications Suction Flow Rate of Vacuum Suction Type (Reference values) Size 1 2 3 7 10 20 30 50 Fluid Air (Non-lube) Size Suction

MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.

to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 12 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V Selects the analogue input range. -10..10 V Channel 2 Analogue input range Sets the analogue input device range. 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

Proper tightening torque (Nm) C(D)U10-D 50 (75) 56 (86) 62 (92) 68 (98) 74 (104) 80 (110) 6, 10 16 20, 25 32 1.08 10% 2.45 10% 5.10 10% 8.04 10% M3 M4 M5 M6 C(D)U16-D 95 (128) 106 (143) 117 (154) 128 (165) 139 (176) 150 (187) 172 (209) 194 (231) C(D)U20-D 176 (230) 193 (252) 210 (269) 227 (286) 244 (303) 261 (320) 295 (354) 329 (388) C(D)U25-D 262 (335) 286 (364) 310 (388) 334 (412) 358

12 219 237 21 32.6 62.8 18.5 10 86.3 30 29.7 25 R3/8 65.5 67.6 60.1 27.7 61.2 53.7 20.6 221 239 22 34.4 64.6 20.9 12 239 257 21 32.6 62.8 18.5 10 86.3 30 29.7 25 R1/2 65.5 71.1 63.6 27.7 62.9 55.4 24.1 239 259 22 34.4 64.6 20.9 12 Note 1) d indicates the applicable tubing O.D.

ZS-27-01 847 Series PSE300 Specifications Model PSE3 PSE533 PSE543 PSE563 PSE531 PSE541 PSE561 PSE532 PSE530 PSE560 PSE564 PSE550 Applicable pressure sensor Set (differential) pressure range Setting/Display resolution Pressure range Note 1) 0.2 to 2 kPa 0.01 kPa 50 to 500 kPa 1 kPa 0.1 to 1 MPa 0.001 MPa 10 to 100 kPa 0.1 kPa For low pressure 0 to 100 kPa 10 to 0 kPa 10 to 101 kPa 0.1 kPa

D L KFP-04 KFP-06 KFP-08 KFP-10 KFP-12 4 6 8 10 12 6.5 8.5 10.4 13 15 12 12 12 13.5 14 99 Series KF Insert Fittings Swivel elbow: KFV Applicable tube (mm) A Effective orifice (mm 2) H1 (Hex.) H2 (Hex.) H3 (Hex.) H4 (Hex.) Weight (g) Thread R(PT) Part No. L1 L2 L3 L4 M d O.D.

Accuracy [%F.S.] 50% 50% 50% 40% 40% 40% With 1 1/4" connected With 1 1/2" connected 30% 30% 30% With 3/4" connected Elbow piping (2") Elbow piping (1 1/2") 20% 20% 20% Elbow piping (1") 10% 10% 10% 3% 3% 3% 8 7 6 5 4 3 2 1 0 0% 0% 0% 8 7 6 5 4 3 2 1 0 8 7 6 5 4 3 2 1 0 Straight section [d] Straight section [d] Straight section [d] Straight When piping with diameter smaller than the straight