(v) Repeat (iii) to (v) until eight shifts have been performed. (vi) After the last eight shifts, exclusive OR the result of (vi) with the next 1-byte (2nd byte). (vii) The processes (iii) to (vii) are repeated to all the remaining bytes of the message (3rd byte to the last byte). (viii) The 2-byte data of the result of (viii) is the CRC value. (2) Calculation example e.g.)
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V]x1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
Applicable load Lead wire length (m) Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Grommet Reed auto switch Yes 12 V 24 V 2-wire Note 1) Lead wire length symbols: 0.5 m Nil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ
power supply input terminal (U, V, W) to the driver power terminal (U, V, W) Connect the motor ground terminal to the driver ground terminal.
D-F9NL Auto Switch Weight Table Unit: oz Lead wire length Part no. 3m 0.5m D-F9N 36.5 6.5 D-F9B 30.7 5.7 D-F9NV 37 7.0 D-F9BV 31 6.0 Auto Switch Dimensions Auto Switch Internal Circuit (mm) / D-F9N D-F9B D-F9N (V) Split-pin set screw (M2.5 X 4l) Switch mounting screw + 2.7 Indicator light 2.8 Brown (Red) Switch main circuit Switch main circuit Output Black (White) 2 L 2.5 Blue (Black) Part
W 2 J D C 21 B Nil Built-in magnet No Number of auto switches D With auto switch (Built-in magnet) Nil S n 2 pcs. 1 pc. n pcs.
FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R VQ7-6-FPG-DValve replacement parts FHG FJG FIG FHG FJG FIG Description Material VQ7-6-FG-SVQ7-6-FG-DVQ7-6-FPG-DVQ7-6-FG-S-R VQ7-6-FG-D-R VQ7-6-D-R VQ7-6-DNo.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-8 Connection of RS-232C 3.3 Installation HRR Series 3-18 HRX-OM-W002 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance P Peak hold mode Shows the maximum pressure reached at that moment.
Model Note Accessory/Option FH34 0 1 CB-48H Petroleum, Water-glycol, Emulsion to CB-48H-V Phosphoric ester FH44 0 1 Differential pressure indicator CB-52H Petroleum, Water-glycol, Emulsion FH342 CB-52H-V Phosphoric ester FH54 0 1 CB-64H Petroleum, Water-glycol, Emulsion to CB-64H-V Phosphoric ester FH64 0 1 FH34 0 1 CB-49H Petroleum, Water-glycol, Emulsion to CB-49H-V Phosphoric ester FH44
For mounting D-A9(V), M9(V), M9W(V), M9A(V) with 32 to 50 to a surface other than the port surface, order an auto switch mounting bracket separately.
unit Model D-RNK D-RPK Applicable amplifier unit D-M9K, D-Y7K, D-F7K Applicable load Relay PLC Voltage output 12 to 24 VDC Current output 40 mA or less Output type NPN 2 output PNP 2 output Load voltage 28 V or less Load current 80 mA or less / 1 output Internal voltage drop 1.5 V or less Leakage current 100 A or less / 1 output Response time 1 ms or less Impact resistance 98 m/s2 Insulation
PSE3 0(T) PSE3 1(T) NPN open collector output: 2 outputs NPN open collector output: 2 outputs Max. 30 V, 80 mA Residual voltage 1 V or less Max. 30 V, 80 mA Residual voltage 1 V or less Analogue output: 1 to 5 V Output impedance: Approx. 1 k Analogue output: 4 to 20 mA Max. load impedance: 300 (12 VDC) 600 (24 VDC) Min. load impedance: 50 PSE3 2(T) PSE3 3(T) Auto shift input Voltage
IDX-OM-W016-D Operation Manual Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA3E-23-A,C IDFA4E-23-A,C,L,R,T,V IDFA6E-23-A,C,K,L,R,T,V IDFA8E-23-A,C,K,L,R,T,V IDFA11E-23-A,C,K,L,R,T,V IDFA15E1-23-A,C,K,L,R,T,V Please read this manual prior of using the air dryer. Keep the manual readily available for reference.
Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
Unrestricted 300/50 m/s2 Lubrication Mounting orientation Impact/Vibration resistance Enclosure(2) Dustproof Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 V 6, 12, 24, 48 V 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption
(Default settings) Solenoid Specifications Electrical entry DIN terminal (D) DIN terminal (Y)
When D-A9(V)/M9(V)/M9W(V)/M9A(V)L types with 32 to 50 are mounted on a side other than the port side, order auto switch mounting brackets separately. Refer to page 1230 for details. 1219