Size: 12 (Body Ported), Operation: 1 (External Pilot Solenoid), Port Size: 01 (1/8), Thread: Rc(PT), Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire), Surge Suppressor: Z [Light & Surge Voltage Suppressor (Except Grommet)], Option: B (Bracket)
Actuation: 1 (2-Position Single), Electrical Entry: LL (L-type Plug Connector w/Cover), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: N (NPT)
Actuation: 2 (2-Position Double), Electrical Entry: LL (L-type Plug Connector w/Cover), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: T (NPTF)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF), Bracket: None, CE-Compliant: Q (CE-Compliant)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: S (5VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 4 (220VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: Rc, Bracket: F (Bracket)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF), Bracket: F (Bracket)
Function: 2 (Normally Open), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 6 (12VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: Rc, Bracket: F (Bracket)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT)
Function: 2 (Normally Open), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G)
Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 1 (100VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT)