x 2-9 counter bore depth 7 H effective thread depth C 2-5.4 through M5 x 0.8 unlocking port 5.5 (unlocks when pressurized) U I 6.5 VV D M E M5 x 0.8 Rear cylinder port K M E S 3.2 2 x 2-M5 x 0.8 3.2 16 16 Dust cover (manual unlocking unit) W L G B + Stroke A + Stroke Retraction locking LOCK VH1 W1 Dust cover (manual unlocking unit) M5 x 0.8 unlocking port (unlocks when pressurized) Rod end
Note 16) Select when manifold parts are ordered for maintenance. When assembling the manifold, refer to page 37. -13No. ZK2-OM01301 2.
No.1 No.2 No.3 Input point COM A COM B COM C COM D OFF OFF OFF 64 16 16 16 16 OFF OFF ON 0 OFF ON OFF 16 8 8 OFF ON ON 16 16 ON OFF OFF 32 8 8 8 8 ON OFF ON 32 16 16 ON ON OFF Reserve ON ON ON : It cannot be set to 0 simultaneously for input and output point. -22No.EX-OMI0003-H Output setting (Switch No.4 to 6) The setting at shipment is turned OFF, set to 64.
A B C D A B C D Bore size (mm) Port aperture A 12 (1) (1) (1) CUJ 16 (2) (2) (2) CU B D 20 (2) (2) (2) View from piston rod end 25 CQS (2) (2) (2) 32 C (2) CQM 40 (2) CQ2 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (2) RQ Operating Range Auto Switch Mounting
Refer to the attachment table on page 14-2-12 or 14-2-16 for standard bypass port sizes applicable to AC.
wire 12 V 3-wire (NPN) 5 V, 12 V Diagnostic indication (2-color indicator) IC circuit Relay PLC 24 V 3-wire (PNP) 2-wire Yes Grommet 12 V 3-wire (NPN) 5 V, 12 V 12 V Water resistant (2-color indicator) IC circuit M9PAV1 M9PA1 3-wire (PNP) 2-wire M9BAV1 M9BA1 A96V A96 3-wire (NPN) IC circuit 5 V 100 V 24 V Yes A93V 2 A90V A93 Grommet Relay PLC 2-wire 12 V A90 IC circuit No 100 V or less
5 7.5 3.5 3 6.5 8.5 8 10.5 1.5 2 6 7 8 12 1.5 (4) 4.5 5 9 10 11 15 2 (4.5) Bore size (mm) 1.5 (1) 3.5 (1) 3 (0.5) 5.5 (3) Long Stroke 12 16 20 25 32 40 1 0.5 6 8 10.5 16.5 11 10.5 16 18 20.5 26.5 9 9.5 13 14 12.5 16 5 5.5 9 10 8.5 12 7 6 11.5 13.5 16.5 22.5 5 (2.5) 8 8.5 12 13 11.5 15 10 9.5 15 17 19.5 25.5 8 8.5 3.5 1 1.5 7.5 4.5 (2) Bore size (mm) 10 (7.5) 12 (9.5) 14.5 (12) 20.5 (18)
Note 2) Mounting threads for pressure gauge: AW10: 1/16, AW20 to 30: 1/8, AW40: 1/4.
Number of auto switches Number of fingers 2 2 Nil 2 S 1 n n Bore size 10 10 mm 16 16 mm 20 20 mm 25 25 mm Auto switch Nil Without auto switch (Built-in magnet) For applicable auto switches, refer to the table below.
Connector pin numbers PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 4 4 0.5 0.5 4 3 16 16 2 2 40 40 5 5 2 1 Pin no.
NS 14 14 24 24 30 30 45 55 60 LT 49 49 59 59 69 69 79 89 99 LB 20 25 30 LA 10 10 20 20 30 30 20 25 30 J 4 4 4 4 4 4 6 6 6 Stroke (mm) 5 10 15 20 25 30 40 50 60 D-X 25 MXH Series Dimensions: 16 LT 16 24 14 LA LB J x M4 x 0.7 Depth 6 2 x 2 x M5 x 0.8 Cylinder port (With plug for port) 3 x M5 x 0.8 through Pilot hole dia 4.3 2 x 3 x 7.5 counterbore depth 4.4 4 x M4 x 0.7 Depth 10 2 x M5 x 0.8
. 1-16 1.8 Material Safety Data Sheet (MSDS) . 1-16 Chapter 2 Name of Each Section . 2-1 2.1 Name of Each Section . 2-1 Chapter 3 Transporting and Installation . 3-1 3.1 Transporting . 3-1 3.1.1 Transporting with forklift . 3-2 3.1.2 Transporting with caster . 3-3 3.2 Installation . 3-3 3.2.1 Installation conditions . 3-4 3.2.2 Installation location and maintenance work area . 3-5 3.3 Procedure
Diagnostics type 2 Table 9-7 Overview of Diagnostics type 2 Byte Description 0 General diagnostics 1 1 Valve diagnostics 1 2 General diagnostics 2 3 Valve diagnostics 2 9.1.2.1.
-6-1 16-6-7 16-5-1 16-7-1 16-8-1 16-4-5 16-2-1 16-2-15 16-2-45 16-2-28 16-2-36 16-2-48 16-1-4 16-1-5 4 Mechanical Pressure Switch Series Mechanical Pressure Switch Series Model Selection Table Positive Pressure Negative Pressure IS3000 IS1000 ISG11/ISG21 ZSM1 ISG19/ISG29 ISG13/ISG23 ISG12/ISG22 Model Fluid General pneumatic General pneumatic General fluids Calibration method Pressure adjusting
D-F5W, J59W D-F5BAL D-F59F D-F5NTL 35 145 155 BS1-125 BS1-140 BS1-160 D-A3, A4, G39, K39 (n 4) 2 (n 2) 2 (n 4) 2 155 + 55 35 + 55 145 + 55 "n" pcs. (same side) n = 4, 8, 12, 16 ... n = 2, 4, 6, 8 ... n = 4, 8, 12, 16 ...
Cassette base 1OS EM D W SSsV W 165 -In",o"u," set Valvestations B E port position 2 stalions Note 1) Doube wiring speciiication I stalions 2 siaiions Specitied tayoul (Up lo 16 solonoids possible ) 16 slations U side (2 to 10 slations) D side (2 to l0 slalions) Both s des (2lo 16 statpns) Supply/Exhaust block assembly specification Nole 1l Doube wn.g specilicalon Shgle doubeafdlJ poston
Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 kW = 6 V Example: Load impedance is 3 kW. Leakage current from auto switch is 1 mA.
154 71.5 82.5 82.5 56(71) 56(71) 49(64) 49(64) 16(20)(B port) 16(20)(A port) 31(42) 31(42) Mounting hole 2-7.5 P R2 R1 VK Manual override A B PB (11) 10 12 (16) 16 (23) (22) 16 VZ 62(72) 75(86) 62(72) 75(86) 50 A VF Cable with connector PA R1 R2 P VFR (L 500) B A Mounting hole 2-7.5 5-3/8, 1/2, 3/4 2-1/8 49(64) 49(64) 44 (58) 44 (58) 18 (20) (20) 18 Indicator light (P , A, B, R1, R2) VP4
22.5 30 5 to 16 2 to 19 2 to 8.5 2 to 26.5 40 6.5 to 17 16 to 28 3 to 9 24 to 36 Symbol: A23 Symbol: A24 The long shaft can be further shortened by machining right-angle double-sided chamfer onto it.