EA P EB In common Type 42 Bar stock type/Common External EXH Individual wiring SY3 40 SY5 40 P. 79 The base mounting facilitates maintenance after valves are changed.
Valve model Port size VCS21 VCS20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCS30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCS30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCS30-12-04 VCS41 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCS Direct Operated
Valve model Port size VCL2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCL4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCL Direct Operated
17.5 42 62 M14 x 2 35 M12 x 1.75 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z Nil TN TF 80 (56 x 2) 10.6 17.5 10 Rc1/4 NPT1/4 G1/4 24.5 23 37 38 64 55 155 118 184 25.5 42 M12 x 1.75 18 9.5 100 (71 x 2) 12.5 20 12 Rc1/4 NPT1/4 G1/4 31.5 25 38 40 74 71 187 141.5 219 27.5 46 M14 x 2 21 11 9 JMGP Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke
Refer to front matters 42 and 43 for Safety Instructions and pages 6 to 8 for Air Preparation Equipment Precautions.
Dimensions AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 L1 L2 L4 Min.
Specifications Air 1.5 MPa 1 MPa 0.05 MPa 5 to 60C (No freezing) Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature How to Order Symbol AS 42 0 02 Option Body size Nil None 42 50 60 80 90 1/2 standard 3/4 standard 1 standard 1 1/4 standard 1 1/2 standard High temperature (5 to 80C) Low temperature (30 to 60C) H (1) Bore size Bore size Applicable
4 [ ]: Denotes the values of AC. 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st Bore size (mm) LA H F D LY NN C LX Y B LC LT MM X A LB LH LZ NA NB S Z Z S Z S Z S 96.5 [97.5] 104 [105] 96.5 [97.5] 105 [106] 116 [117] 117 [118] 128 [129] 129 [130] 10 16 28 8 4 M8 x 1 14 24 7 84 12 1.6 5 72 15 15 9 32 9.5 60 37.5 4.5 16.5 M4 x 0.7 12.5 52.5 28 8 5 M10 x 1 20 33 9 85 18 2.3 6 73 15 23 14 42
H 28 30 36 44 54 E 22 21 26 F 45 55 58 65 76 G 33 42 44 50 61 D 34 46 63 67 78 A 59 78 107 110 134 B 20 29 39 42 53 C 40 53 70 75 90 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1938 Series VHS20/30/40/50 Specific Product Precautions Be sure to read before handling.
30.5 32.5 30 50 50 41 42 48 44.5 47.5 43.5 36.5 38.5 36 63 56.5 47.5 48.5 54.5 51 54 50 40 42 39.5 10-10-13 14 Series RZQ Mounting of Auto Switch Follow the procedures below to mount auto switches.
A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,
Acknowledgment and restart . 38 3 No.EX##-OMY0011-A Appendix A: Glossary for PROFIsafe . 39 Appendix B: Parameters for PROFIsafe . 41 Appendix C: Checklists . 42 Appendix D: Safety Characteristics . 47 Appendix E: EX260-FPS Timing Values . 48 Appendix F: Failure modes . 49 4 No.EX##-OMY0011-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or
Addresses 0hex and Fhex are not permitted. 66 42 Correct value. 67 43 Invalid parameterization of F_WD_Time. A monitoring time of 0 ms is not permitted. Correct value. Invalid parameterization of F_SIL. The safety module (F-Module) cannot support the required SIL. Use a module with the required SIL.
Safety Mode (Channel Passivation) Safety Mode (Module Passivation/xxx)10.6 42 No.EX##-OMY0006CN Output feedback parameter SI Table 8-5 Output feedback parameter Enable Table 8-5 No. Bit (*) Bit (*) 1 0 I/O M 0 0 IN0 [0 and 4] 2 1 zone1 Z1 1 1 IN1 [1 and 5] 3 2 zone2 Z2 2 2 IN2 [2 and 6] 4 3 zone3 Z3 3 3 IN3 [3 and 7] (*) 10.9.2 LED 2 43 No.EX##-OMY0006CN 9. 9.1.
When the output specification of the copy destination display setting device is not 6, the output specification should be set to copy input in accordance with the [F 5]FUNC terminal setting (page 42) beforehand.
For details of each setting, refer to page 17 to 42 of this manual. The Pressure switch is compulsory turned off for 1 seconds after power supplied. For 4 seconds after supplying power, the measurement output is turned off. Maintenance Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance.
Accumulated pulse output is selected: Refer to page 42 d. Error output is selected: Refer to page 43 e. Output OFF is selected: Refer to page 43 Press the SET button to set. Return to function selection mode.
Nominal thread size Tightening torque Rc(NPT)3/8 15 to 20 Nm Rc(NPT)1/2 20 to 25 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm Rc(NPT)1 1/4 40 to 42 Nm Rc(NPT)1 1/2 48 to 50 Nm If the tightening torque is exceeded, the product can be broken. If the correct tightening torque is not applied, the fittings may become loose. Avoid any sealing tape getting inside the piping.
(page 141) -142No.PF-OMA1007-B Air Management Hub Base type EXA1-20/30/40-PN/EN/EC-# Model A B C D E F EXA1-20 236.2 35 42 19.1 65.1 30.5 EXA1-30 236.2 43 53 13.6 65.1 30.5 EXA1-40 240.4 51 64.4 4.6 71 35.5 -143No.PF-OMA1007-B EXA1-60-PN/EN/EC-# -144No.PF-OMA1007-B Remote type EXA1-20/30/40-SA-# Model A B C D E F G EXA1-20 236.2 35 42 19.1 65.1 30.5 74.7 EXA1-30 236.2 43 53 13.6 65.1 30.5
Therefore, the seal kit includes 42 (large cushion seal) and 43 (small cushion seal) . Please check the specification before use and select suitable cushion seal. C a u t i o n The seal is not delivered in sealed packaging for independent storage, so it must be used within 1 year. 4-1-2.