SMC Corporation of America
Elite Part Number Search
Search Results "VV5FR2-10-101-02T"

Series 10 12 16 20 25 32 40 50 63 80 100 MHZ2 3.0 5.0 7.0 7.0 8.0 8.5 MHZL2 6.0 7.0 10.0 11.0 MHL2 7.0 8.0 8.5 10.5 11.0 12.5 MHS2 6.5 7.0 7.5 8.5 MHS3, MHS(L)3 6.5 7.0 7.5 8.0 MHS4 6.5 7.0 7.5 8.5 MHC2 30 to -10 30 to 30 to 22.5 to -10 -10 -10 MHW2 88 to 54 to 58 to 41 to 30 to -4 -5 -6 -5 -5 Air cylinder Unit: mm Tube I.D.

to 330 20 to 180 24 to 750 16 to 500 8 to 250 30 to 1140 20 to 760 10 to 350 range 801 to 900 24 to 610 16 to 410 8 to 200 30 to 930 20 to 620 10 to 280 Actuator specification 901 to 1000 24 to 500 16 to 340 8 to 170 30 to 780 20 to 520 10 to 250 1001 to 1100 30 to 660 20 to 440 10 to 220 1101 to 1200 30 to 570 20 to 380 10 to 190 10 Max acceleration/deceleration [mm/s2] 5000 Positioning

Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-26 10-1. Bowl Assembly Replacement 23-24 10-2. Element Replacement 25-26 11. Disassembly Drawing 27 12.

Model selection PsAllowable pressure Refer to page 21, Table 10 PsAllowable pressure Refer to page 21, Table.10 Es Allowable kinetic energy Refer to page 21, Table 10 13/28 In this series, the work load and the maximum operating pressure are restricted to prevent the magnetic coupling from being separated.

Assembly and disassembly of the SI unit -35No.EX-OMP0013-E Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Pollution

(mm) 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.

Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-26 10-1. Bowl Assembly Replacement 23-24 10-2. Element Replacement 25-26 11. Disassembly Drawing 27 12.

DC12~24V10% DC12~24V10% DC(+) DC(-) 8 DC12~24V10% DC12~24V10% DC(+) DC(-) 9 ( ) 10 11 -72No.PS-OMU0005CN-C No. / / 5m 12 1015 10 SI (kPaMPa) ( ) SI kPa,MPa 13 14 15 16 FUNC 17 -73No.PS-OMU0005CN-C No. 4m 4m FUNC 18 (Er13) 10 10 () 19 ( ) / () -74No.PS-OMU0005CN-C 80mA 7F.S.(3.5F.S.) 1 1 F.S. 1 -75No.PS-OMU0005CN-C ZSE20B() ZSE20BF() ISE20B() 0.0-101.0 kPa -100.0100.0

Hysteresis 0 to variable 7 Withstand pressure 600 kPa Detection nozzle 1.5 4 Current flow 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple(p-p) 10% or less (with power supply polarity protection) Current consumption 25 mA or less Switch output 2 output (NPN or PNP) Max. load current 10 mA Max. applied voltage 26.4 V Residual voltage 1 V or less (at

/CLR, number of stations occupied and mode are performed with SW2. 10 9 8 7 6 5 4 3 2 1 ON ON Station number setting (Switch No.1 to 7) Set tens digit of station number 10, 20 and 40, and set ones digit of station number 1, 2, 4 and 8.

x 1.5 23 100 1/2 21 130 40 204 4 End Lock Cylinder Series CBG1 With front lock: CBG1BN Bore size Stroke R GB (mm) Bore size (mm) DL1 GB S TB ZZ 20 19.5 10 (12) 80 (88) 11 117 (125) 25 19.5 10 (12) 80 (88) 11 122 (130) 32 20 10 (12) 81 (89) 10 (11) 123 (131) 40 19 10 (13) 87 (96) 10 (12) 139 (148) 50 23.5 12 (14) 102 (114) 12 (13) 162 (174) DL1 63 23.5 12 (14) 102 (114) 12 (13) 162 (174

Grease pack (10 g) 1 pc. IN 84.8 59 42 25 CQSY16-PS 12 6 OUT 113 79 57 34 CQSY20-PS IN 151 106 75 45 CQSY25-PS 16 8 OUT 201 141 101 60 When only grease for maintenance is necessary, please order by the following part numbers.

64 22 44.3 32.8 18.5 10 101 21 47.9 33.6 24 17 28.6 R 1/2 24.5 58.7 51.2 51.4 43.9 20.9 12 107 22 49.5 35.2 Note 1) Reference dimensions Note 2) Reference thread dimensions after installation. 606

Value range: 10 10, in 1 ms increments Unit: ms F_WD_Time 150 A CRC signature, which is calculated automatically via all F-Parameters and ensures error-free transmission of the F-Parameters.

If an instantaneous flow of 10 L/min continues for 5 minutes, the accumulated flow will be 10 5=50 L. Accumulated flow external reset A function to reset the accumulated flow to zero by using an external signal. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.

15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12 ( SUS304 M 3 M SUSU316L 8 11 SUS304 2 7 A6063 6 9 6 9 10 9 5 SUS304 4 5 10 4 10 S O S O XLD-25 XLD-40,XLD-50,XLD-160 XLD-63,XLD-80,XLD-100 S 1 SUS304+ 4 1) S S O 2) S O FKM 5 O 6 S O 2 FKM 9 S SUS304 10 11 XL-OMY0002 6. 6-1.

L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L Fig. 9 Position for application of grease Table 10 Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 20 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig.9, ) Pay attention to the mounting direction of the seal.

(V) 24 Allowable voltage fluctuation -10 to 10% Power consumption (W) 0.4 [Starting 0.4, Holding 0.1] Please refer to page 1367 of Surge voltage suppressor the Best pneumatics catalogue.

Length TH0402 TJG-0402 18 4 TUS0425 TH0425 TJG-0425 18 TL0403 TJG-0403 18 6 TUS0604 TH0604 TL0604 TJG-0604 19 8 TUS0805 TJG-0805 20.5 TH0806 TL0806 TJG-0806 20.5 TUS1065 TJG-1065 23 10 TH1075 TJG-1075 23 TH1008 TL1008 TJG-1008 23 TUS1208 TJG-1208 24 12 TH1209 TJG-1209 24 TH1210 TL1210 TJG-1210 24 *Stainless steel 316 is used for the TJG series. 10 - Cross Reference Table of the Inner Sleeve