B C D E F G H P U Load (kn) Weight (g) M A MB JA30-10-125 JA40-12-125 JA50-16-150 JAH50-20-150 JA125-27-200 JA160-36-200 2.5 4.4 11 18 28 71 M10 X 1.25 M12 X 1.25 M16 X 1.5 M20 X 1.5 M27 X 2 M36 X 2 49.5 60 71.5 101 123 178 19.5 20 22 28 34 51 22 24 25 30 38 55 24 31 41 59,5 66 96 5 6 7.5 11.5 13 16 8 11 14 24 27 36 8 11 13.5 16 20 24 17 22 27 32 41 55 9 13 15 18 24 42 0.5 0.75 1.0 2.0 2.0
of read outputs: 16 bits (10h) 12 1 (Number of bits) 13 0 Calculated 14 value Checksum(LRC) 15 Calculated value 16 End code CR 17 LF Note 1: The maximum value is 456 bits.
SRP1-M5 SRP1-01 Pressure gauge part no.
Bore size (mm) Part No. d l Cotter pin d m H B Dd9 L C D (Cut through) Note 1) 3 x 18l 4 x 25l 4 x 35l 10 14 22 32, 40 50, 63 80, 100 32 40 50, 63 80 100 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 36 51 72 4 4.5 5 6 8 11 13 16 17 22 27 32 41 44 60 82 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 0.040 0.076 0.050 0.093 0.065 0.117 3 4
Ambient temperature 0 to 40C IZS40/41/42 IZT40/41(-L)/ 42(-L)/43(-L) IZN10E IZF IZG10 ZVB IZD10/IZE11 IZH10 Antistatic Equipment Air supply*3 Fluid Air (Clean, dry air) Operating pressure 0.05 to 0.6 MPa Connecting tube size 8 (Metric), 5/16" (Inch) Power supply voltage 24 VDC 10% (21.6 to 26.4 V) Current consumption 90 mA (typ.)
16 *LEH ) 10mm (25 ) () 30mm 60mm 30mm 50mm DIN ) 16 - 4. 4.1 (STATION NO.B RATE) CC-Link CC-Link 0164 CC-Link STATION NO.
Reference Information . 41 8. 1 Checksum Calculation Procedure . 41 8. 2. Checksum Calculation Examples . 41 8. 3 Communication Response Time Guides . 41 8. 4 ASCII Code List. 42 3 LATCA Series Controller 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
'H" 'e o :" ;iC:t1 32 164 173.5 :,. 40 ' 184 196 " 50"', 202 21' 9,5 -500 22 12 10'1'" 26 12,%~ -500 12 15 25 28 :, -600 27 12 15 32 ' 21~ 63' 222 238 -600 32 16 16 1~ 20 40 x 80 266 -750 16 1 61~ 36 20 50 250 100. 01~ 290 41 -750 20 25 60 270 -ZZ+Srroke Double rear clevis / (D) U l RR Z+Stroke ZZ...
stations) 1 to 12 stations (16 stations) 24 1 to 12 stations (16 stations) 24 1 to 12 stations (16 stations) 24 1 to 10 stations (16 stations) 20 EX250-SPR1 EX250-SDN1 Note 2) T kit 1 to 12 stations (16 stations) 24 EX250-SDN1-X102 Note 3) 1 to 4 stations (8 stations) 1 to 2 stations (4 stations) 1 to 4 stations (8 stations) 1 to 2 stations (4 stations) 8 4 8 4 EX250-SAS3 EX250-SAS5
M L K J H E t W1 W2 M 14 20 25 29 37 49 58 69 89 100 117 136 14.5 20.5 24.5 30.5 36.5 48.5 6 7 7 9 9 10 11 16 21 24 32 41 10 17 22.5 24.5 27 30 16 21 26 32 41 50 17 24 28 36 43 55 8 8 8 8 13 13 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3P1A LQ3P2A LQ3P3A LQ3P4A LQ3P5A LQ3P6A 1/4 (E) (E) L Panel Aperture (K) Straight Union : LQ3U (mm) Inch Size H Model Tubing O.D.
Mass (g) D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Precautions Caution 0.5 8 8 7 1 14 14 13 Lead wire length (m) 3 41 41 38 Do not fix the auto switch with the existing screw installed on the auto switch body.
") Bushing I.D. 3/16" (Inch) Symbol Bore CJ CG CF CE CD CC 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.75 0.19 0.56 0.25 3/16 0.38 0.81 0.25 0.56 0.25 3/16 0.38 1.19 0.25 0.94 0.44 3/8 0.75 1.34 1.25 0.31 0.94 0.44 3/8 0.75 0.380.005 0.56 0.19 1.31 0.38 0.93 0.44 3/8 0.75 1.090.015 0.25 0.75 Symbol Bore 075 (3/4"), 106 (1-1/16"), 150 (1-1/2"), 200 (2"), 250 (2-1/2") CM CL
ATEX Intrinsic Safety Type of Explosion Protected Construction 16 Explosion Protected Construction Rate 16 Wiring 16 Barrier 17 Description of Components 18 Contents of LCD Display 18 Initial Adjustment 19 Change of Parameters for Initial Operation 19 Initial Adjustment 19 1.Selection of calibration mode 19 2.Check angle of feedback lever 20 3.
Return to origin . 41 8.1 Return to origin . 41 8.2 Positioning operation . 41 8.3 Pushing operation. 42 (1) Pushing operation is successfully performed. . 42 (2) Pushing operation is failed (pushing the air) . 42 (3) Movement of the work piece after the completion of the pushing process .. 42 8.4 Controller input signal response time . 43 8.5 Methods of interrupting operation . 43 9.
16 16 16 17 17 17 17 21 21 21 21 21 21.8 21.8 21.8 22 22 22 25 17 16 16 16 21 17 17 17 17 17 21 21 21 16.8 20.4 20.4 2 22 22 25 1.6 1.6 1.6 1.6 3.5 3.5 3.5 3.5 3.5 3.5 5.4 5.4 5.4 4.6 7.0 7.0 8.5 8.5 8.5 9.8 23 15 16 23 40 16 23 37 40 53 36 44 68 76 64 76 43 51 76 126 100/400 100/400 100/400 100/400 100/200 100/400 100/400 100/400 100/200 100/200 100/200 100/200 100/100 100/100 100/100 100
No.JXC-OMU0004-A (DC24V) / LECP1 Series 1. . 4 2. . 6 2.1 . 6 2.2 . 7 2.3 . 8 2.4 () . 9 1 . 9 2 . 9 3 . 9 4ON . 10 5(). 10 6 . 10 3. . 11 3.1 . 11 3.2 . 12 3.3 . 13 3.4 . 14 1 . 14 2 . 14 3 . 15 4. . 16 4.1 CN1 . 16 4.2 CN2CN3: . 16 4.3 CN4I/O . 16 5. CN . 17 5.1 . 17 5.2 . 17 (1) . 17 (2) . 18 (3) . 18 6.
1.7.3 System disposal . 1-16 1.7.4 Label . 1-16 1.8 Material Safety Data Sheet (SDS) . 1-16 1.8.1 Galden HT135 . 1-17 1.8.2 FluorinertTM FC-3283 . 1-29 1.8.3 Galden HT200 . 1-38 1.8.4 FluorinertTM FC-40 . 1-50 1.8.5 Ethylene glycol aqueous solution 60% . 1-58 1.8.6 Refrigerant R410A . 1-64 1.8.7 Refrigerant R448A . 1-76 Chapter 2 Name of Each Section . 2-1 2.1 Name of Each Section (1) .
Model Weight [kg]*1 Dimensions [mm] HRR010-A 43 Height 485 x Width 610 x Depth 820 HRR010-W 41 Selection HRR012-A HRR018-A 54 Warning Height 575 x Width 610 x Depth 820 HRR012-W HRR018-W 55 1. Model selection When selecting a thermo-chiller model, the amount of heat generation from the users equipment must be known.
22 (0.15) to 150 (1.0) AT F (C) Ambient temperature 36 to 104 (2 to 40) Relative humidity of 85% or less Air flow capacity 37F (2.8C) 10 (17) 15 (25) 25 (43) 41 (70) 59 (100) 71 (120) Outlet air pressure dew point IDF IDU 45F (7.2C) 11 (19) 16 (27) 26 (45) 43 (74) 62 (106) 80 (136) Outlet air pressure dew point SCFM Note 1, 2) (m3/h (ANR)) 50F (10C) 12 (20) 17 (28) 28 (47) 45 (77) 65 (110
1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3