Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Clevis, Port thread type: Rc, Body Options:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch

Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 70, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Guideless] Prototype, Table Size Width W(mm): 46, Table Size Height H(mm): 46, Table Surface Treatment: No, Operating Pressure(MPa): 0.18 to 0.7, Environment: General Purpose, Maximum Load(kg): 1.2, Operating Speed(mm/s): 50~300

Load Mass (Horizontal Mounting)(kg): 1~4.9, Table Size Length L(mm): 70, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Guideless] Prototype, Table Size Width W(mm): 46, Table Size Height H(mm): 46, Table Surface Treatment: No, Operating Pressure(MPa): 0.18 to 0.7, Environment: General Purpose, Maximum Load(kg): 1.2, Operating Speed(mm/s): 50~300

, Pilot Air Supply: External Mount, Seal Type: Standard, Plumbing: Direct Plumbing, Flow Coefficient (Cv): 17, Lead wire electrical entry: None, Indicator light / Surge voltage suppressor: None, Option: None, Body size: 70

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1.0, Support bracket: Clevis, Port thread type: Rc, Body Options:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet