SMC Corporation of America
Elite Part Number Search
Search Results "RS2H63TF-30TM-DC"

24V output Output 2 DC 24V output Output 3 DC 24V output Output 4 Contact input signal 1 Input None 5 COM of contact output signal 1 Output 6 COM of contact output signal 2 Output 7 COM of contact output signal 3 Output 8 None 9 24 COM output Output 10 24 COM output Output 11 COM of contact input signal Output 12 Contact input signal 2 Input None 13 Contact output signal 1 Output Run status

This product side Customer system side DC +24V(output) DC24V 1 DC +24V(input) EXT DC24V 2 Power supply 24COM(output) 14 EXT 24COM 24COM RunStop 3 4.7k External switch 16 When using a customer's power supply, connect the 24V DC + side to pin 2 and the COM side of each contact input signal to the customer's power COM. 4.7k Operation mode request (Momentary) 4 4.7k DC24V 6 Contact output 1 :

This product side Customer system side DC +24V(output) DC24V 1 DC +24V(input) EXT DC24V 2 Power supply 24COM(output) 14 EXT 24COM 24COM RunStop 3 When using a customer's power supply, connect the 24V DC + side to pin 2 and the COM side of each contact input signal to the customer's power COM. 4.7k External switch 16 4.7k Operation mode request (Momentary) 4 4.7k DC24V 6 Contact output 1 :

This product side Customer system side DC +24V(output) DC24V 1 DC +24V(input) EXT DC24V 2 Power supply 24COM(output) 14 EXT 24COM 24COM RunStop 3 When using a customer's power supply, connect the 24V DC + side to pin 2 and the COM side of each contact input signal to the customer's power COM. 4.7k External switch 16 4.7k Operation mode request (Momentary) 4 4.7k DC24V 6 Contact output 1 :

Electrical Specifications Item Specification Power supply Applied voltage:DC24 V10% Current consumption: 0.5 A (Maximum 2.5 A) Control system Closed loop Positioning sensor Absolute Analog input signal DC 4 to 20 mA Analog input impedance Approx. 250 Analog output signal DC 4 to 20 mA Maximum load impedance (Analog output) 500 Voltage across terminals DC12 V (Input impedance worth 600

+) (LINE(+)) 2 3 (DC-) 4 (IN15 V) (LINE(-)) A A PSE200/PSE300 (ZS-28-C) 3M 37104-3101-000FL 1473562-4 XN2A-1430 PSE200 PSE300 -9No.PS-OMG0005CN-E DC+ OUT PSE5615V 1 k DCLINE+ PSE56--28 420 mA 500 (24 V ) 100 (12 V ) LINELINE(+)LINE(-) -10No.PS-OMG0005CN-E (A/D ) () 20 2030 -11No.PS-OMG0005CN-E PSE560 PSE561 PSE563 PSE564 01 MPa 0-101 kPa -100100 kPa 0500 kPa -0.10 MPa 10.10

Voltage specification Colour DIN connector B1B09-2A (Standard) GM209NJ-B17 (CE-compliant) 100 VAC Blue 200 VAC Red DC polar indication Red (+), black (-) Others Gray 7 VT307-OMQ0002-B VT307 Series 3 port solenoid valve/ Specific Product Precautions (2) Be sure to read before handling.

Therefore, when it is continuously energized or the energized period per day is longer than the de-energized period use either: DC specification, power-saving type. Also, please contact SMC because depending on the application, there may be additional valves not mentioned above that may be used.

DC coil Should be 3% or less of the rated voltage. 4 No.VQC1000V-OMM0002-B VQC1000/2000 Series Precautions for 5 Port Solenoid Valve Be sure to read before handling. 5. Operation in low temperature condition Design / Selection It is possible to operate a valve in extreme temperature, as low 3. Surge voltage suppressor Caution as -10 .

PLC input part CEU5B-* BCD output part PLC input part CEU5BBCD output part (for photo-coupler input) (for photo-coupler input) (for NPN output type) (for NPN output type) Output specification: open collector Output specification: open collector Max. : 30VDC, 15 mA DC power DC power Max.: 30VDC, 15 mA (5) Output timing Data in BCD output Data in BCD output Data 1 Data 2 Data 1 Data 2 DATA

DC is 3% or AC is 8% or less of rated voltage. 3) Failure of pilot valve Foreign matter caught in core of pilot valve. Disconnection coil wire of pilot valve Swelled out poppet of pilot valve Burnt coil of pilot valve (Higher voltage or wrong coil Replace part or re-wire positively. Check voltage. Replace valve. (Pilot valve) Replace valve (pilot valve).

Plug-in type(With terminal block) Grommet with DC voltage surge voltage suppressor has polarity. Connect red lead wire to + (positive) side and If you remove the junction cover (1) on the sub-plate, you black to (negative) side. will see the plug-in terminal block (2) attached to the inside of sub-plate.

Grommet with DC voltage surge voltage suppressor has polarity. Connect red lead wire to + (positive) side and black to (negative) side. Terminal block type Remove cover (1), over terminal block (2) attached to the inside of body. Connect with corresponding power side.

Keep the residual voltage at 3% of the rated voltage (DC coil) or less. 3) Failure of the installed pilot valve Pilot valve coil breakage Foreign matter is caught in the Replace the pilot valve assembly. Clean the air supply Check the voltage, and replace the pilot pilot valve armature.

DC coil VEX1101, VEX1201, VEX1301 2% or less of rated voltage VEX1501, VEX1701, VEX1901 3% or less of rated voltage 6. Not suitable for use as an emergency shutoff valve, etc.

B Z + Stroke DB DX DD 90 B 4-DT A DS DH 4-DR DL DU DO DO DC DE DU DA Rotating Angle Bore size (mm) Part no.

(42mA) 1W DC (83mA) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) Power consumption (Current) 24VDC 12VDC 3-position closed center (A) 4 (B) 2 Note 1) Use dry air to prevent condensation at low temperatures.

DC (+) Brown [Red] Main switch circuit DC () Blue [Black] Indicator light/Display method (mm) Operating range (l) 10 5 16 Bore size (mm) 5 16 Water Resistant 2 Color Indication Solid State Switch Band Mount Type D-G5BAL Auto switch specifications D-G5BAL (with indicator light) Grommet D-G5BAL Auto switch part no.

1a 2VA(AC), 2W(DC) 100V or less 12 to 24VAC or VDC: 50mA 48VAC or VDC: 40mA 100VAC or VDC: 20mA IS1000E-3004 IS1000E-4002 Note 2) AC40 AR40, AW40 AWM40, AWD40 IS1000E-4003 12.5 37 62.5 32 80.5 IS1000E-4004 Max. operating current IS1000E-4006 Note 1) in the model numbers indicates a thread type.

Use the following UL approved products for DC power supply combinations. (1) Controlled voltage current circuit conforming to UL508 Circuit uses the secondary coil of an isolated transformer as the power supply, satisfying the following conditions.