50C, Stored: 10 to 60C (No condensation or freezing) Operating and stored: 35 to 85% RH (No condensation) 250 VAC for 1 min, between all lead wires and enclosure 2 M or more (at 50 VDC) between all lead wires and enclosure 10 to 500 Hz with 1.5 mm amplitude or 98 m/s2, whichever is smaller 980 m/s2 in X, Y, Z directions 3 times each (Not energized) 3% F .S. or less of measured pressure at 25C
Characteristic Cable length (L) Multicore vinyl cable 0.3mm2 X 25C Conductor resistance /km, 20C Voltage limit V, 1min, AC 65 or less 1.5m 3m 5m AXT100-DS25-015 Cable 25 core X 24AWG AXT100-DS25-030 10 1000 AXT100-DS25-050 Insulation resistance M/km, 20C 5 or more For other commercial connectors, use a 25-pin female connector made in conformity with MIL-C-24308.
Temperature characteristics 5% F.S. (0 to 50C, 25C reference) Accuracy Output type NPN open collector PNP open collector Output mode Select from Hysteresis, Window comparator, Accumulated output or Accumulated pulse output modes. Switch operation Select from Normal or Reversed output.
Enumeration of operating conditions Collision speed (1) Kinetic energy E1 Thrust energy E2 Absorbed energy E Corresponding (2) weight of impacting object Me m = 50 kg = 0.3 m/s d = 40 mm p = 0.5 MPa n = 20 cycle/min t = 25C m 2 1 2 m 2 1 2 R Operating condition Impacting object weight Collision speed Dropping height Angle speed Distance between axis of cylinder and impact point Bore size
Graph z Round Bar/Chamfered/Roller Graph x Lever 100 200 130 50 40 50 40 100 50 40 Weight of transferred object m [kg] Weight of transferred object m [kg] Example 1 30 40 50 32 20 30 20 Example 2 20 32 16 10 10 12 5 4 3 4 5 3 2 2 * Graph shows the case of a Lever Type with a friction coefficient = 0.1 and at room temperature (20 to 25C). * When selecting cylinders, confirm the Specific
Note 9) Required flow when a load is applied as shown in the cooling capacity when the facility water temperature is at 25C. Note 10) Mass in the dry state without circulating fluids. 80
(p-p) 10% or less (with power supply polarity protection) Current consumption 15 mA or less (with no load) Output specification Analog output 1 to 5 V (with rated pressure range), 0.6 to 1 V (with extension analog output range), Output impedance: Approx. 1 k 2% F.S. or less (with rated pressure range), 5% F.S. or less (with extension analog output range) Accuracy (Ambient temperature at 25C
Actuator Position Sensor D-MP Series Specications Model D-MP025D-MP050D-MP100D-MP200 Measuring range 25 mm1 mm 50 mm1 mm 100 mm1 mm 200 mm1 mm Power supply voltage 15 to 30 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Current consumption 48 mA or less (when no load is applied) Repeatability 1, 2 0.1 mm (Ambient temperature: 25C) Resolution 0.05 mm Linearity 2 0.3
: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: CH1 20C/CH2 25C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest 5 With the pressure control mode by inverter.
), 5% F.S. or less (0 to 50C, based on 25C) 160 mA or less 170 mA or less 290 g 150 mA or less 250 g 1/8, 1/4 3/8 1/2 Heater type 3-digit, 7-segment LED 50 kPa to 0.75 MPa 50 kPa to 0.5 MPa 1.0 MPa 0 to 9 l NPN open collector Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V; 2 outputs Resistance Output specifications
3.5 to 45 L/min 0.35 to 4.5 L/min 2 to 16 L/min 10 to 100 L/min 5 to 40 L/min 0.5 to 4 L/min 0.1 L/min 1 L/min 0.5 L/min 0.05 L/min 0.1 L/pulse 1 L/pulse 0.5 L/pulse 0.05 L/pulse Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Operating fluid temperature Accuracy Repeatability Temperature characteristics Note 1) 0 to 50C 5% F.S. 3% F.S. 3% F.S. 2% F.S. 5% F.S. (0 to 50C, 25C
) 4.8 (4.4 in the end) resin piping (Applicable to I.D. 4 air tubing) Resin pipe: Nylon, Piston area of sensor: Silicon Accuracy (Ambient temperature of 25C) Linearity Repeatability Indication light Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance Environmental resistance Vibration resistance Impact resistance Temperature characteristics
1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?
1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?
1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?
1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?
1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?
1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?
1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?
1% F.S. or less (15 to 35C, based on 25C)?2% F.S. or less (0 to 50C, based on 25C)60 mA or less45 gSwitch outputSwitch outputAccumulated pulse outputEnclosureOperating temperature rangeVoltage resistanceInsulation resistanceVibration resistanceImpact resistanceNoise resistance3-digits 7-segment LEDON: when light is on, OUT1: Green; OUT2: Red12 to 24 VDC (ripple ?