O-
Wire Solid State NPN 28VDC or less 150mA or less D-F7P 3 Wire Solid State PNP 100mA or less D-J79 2 Wire Solid State 24VDC (10~28V) 5 ~ 150mA D-F7NV 3 Wire Solid State NPN 28CVDC or less 150mA or less D-F7PV 3 Wire Solid State PNP 100mA or less D-F7BV 2 Wire Solid State 24VDC (10 ~ 28V) 5 ~ 150mA D-F7PW 3 Wire Solid State PNP 20mA or less D-J79W 2 Wire 24VDC (10 ~ 28V) 5 ~ 40mA D-F7BAL 2
Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.
Example)AC30-F03DM-KSTV-13NR-A q r t y w e q Symbol Bodysize Description 20 25 30 40 Rc NPT G Nil N F Threadtype w + 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 Portsize e + Floattype autodrain a Withoutautodrain N.C.(Normalclose)Drainportisclosedwhenpressureisnotapplied. N.O.(Normalopen)Drainportisopenwhenpressureisnotapplied.
Gauge port 2) (Inlete, Outletr) Porting Configuration Pressure gauge Code r psig/bar unit MPa unit r e No pressure gauge 0 6 10 20 40 60 Q w q w q 600 psig/bar 3) 4.1 MPa 7 MPa 14 MPa 28 MPa 41 MPa 70 MPa qIN wOUT eGauge port (Inlet) rGauge port (Outlet) Connections (Inletq, Outletw) 1000 psig/bar 3) Ports Code 2000 psig/bar 3) Connections 4P V 4PN e 4P 4PN 4000 psig/bar 3) 4 4B NPT 1/4 inch
1 15-9-41 3 Dimensions AS2000E/3000E 2-port size L7 Max. Min. L1 D L2 L3 L4 L5 L6 L8 Model Port size AS2000E-01 4.5 16 57 61.5 15.5 10 17 30 5 40 1/8 AS2000E-02 4.5 20 59 63.5 17 12 23 30 5 40 1/4 AS3000E-02, 03 5.5 26 69 76 20.6 13.25 25 45.5 5.25 56 1/4, 3/8 AS4000E 2-1/4 to 1/2 72 (Max. 80) Effective thread depth 6 15-9-42
Deionized water: Electric conductivity 1 S/cm or higher (Electric resistivity 1 Mcm or lower) Note 3) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 200/400 VAC Note 4) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200/400 VAC
Seat material Connections (Inletq, Outletw) Code Material PCTFE (Standard) Vespel 4) Material Code Connections 1/4 inch face seal (Female) 1/4 inch face seal (Male) 1/4 inch tube weld 3/8 inch face seal (Female) 3/8 inch face seal (Male) 3/8 inch tube weld No code VS FV4 MV4 TW4 FV6 MV6 TW6 Body Poppet 316L SS Hastelloy C-22 Code Diaphragm S SH 316L SS secondary remelt 316L SS 4) Not available
VNH 15A 2 1 1 A Air operated VNH 15A 2 1 1 A 1 D External pilot solenoid CE-compliant Port CE-compliant Nil Q 1 3 3 port 2 port Thread type Option 2 port is 7.0 MPa only.
Dimensions IN574-95 (Sensor head + Display part) 20 40 230 D-F8N (2 pcs.) 110 Red tape 500 20 M12 Connector Tube (3 places) Green tape Sensor head Wiring Terminal no. Description Note 1 +15 V 1 2 1 2 5 2 Output signal 1 D-F8N 3 4 3 4 Display part 3 GND Socket connector A-coded (Normal key) Plug connector A-coded (Normal key) 4 Output signal 2 D-F8N DD1677
3 !1 u u TMH r t r t ASD e !3 e !3 AS q AS-FE !1 !1 i !4 y q q KE i !5 i !5 AS-FG AS-FP AS-FM AS321F-02 Meter-out type AS3201F-02 Meter-in type AS3211F-02 AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ Component Parts No.
No gauge port No pressure gauge No code 0 V3 L 1 H 2 4 Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.
Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) 3 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 200/400 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200/400 VAC 5 q Ambient
Deionized water: Electric conductivity 1 S/cm or higher (Electric resistivity 1 Mcm or lower) Note 3) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 200 VAC Note 4) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC Note 5)
Note 3) Above elements require one element per filter. Construction/Seal List Replacement O-ring/Seal List (One each of the seal and O-ring types listed below are required per filter.) q O-ring order no. w O-ring order no. Differential pressure indicator e Seal washer order no.
Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) Note 3) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: 20C, r Circulating uid ow rate: Rated ow, t Power supply: 200 VAC Note 4) q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC Note
Note 3) Overall weight excluding optional parts 495
R06 L PS 00 10 Option (CE-compliant ) Output specifications Nil None 10 11 12 For positive pressure Q CE-compliant For vacuum and residual pressure The PS1200 series is CEFor vacuum compliant (with Q) only.
Place them in alphanumerical order. q e w Switch Characteristics Description Symbol Example) IS10-N01-6PZ Nil N Rc NPT q q Thread type Max. contact capacity AC 2 A, DC 2 W 24 V or less Note 1) Set pressure range of 6P(L, Z) is 0.2 to 0.6 MPa (30 to 90 psi). This product is for overseas use only according to the new Measurement Law.
Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. 2) Install the valve guide (on the opposite side of the handle) 60 mm away from the ground surface. Maintenance and inspection will be facilitated. 3) Air is normally released from the bleed hole.