VH Roller plunge VFM250-02-06 VFM250-02-06S Panel mounting hole VHS 15 polyacetal or head steel roller Hexagon nut thick 11, across flats 27 (Pilot exhaust port) JIS symbol 0.5 MPa supply 1.5 mm P.T. 20 N F.O.F. 2.0 mm O.T. 3-4.5 mounting hole 3.5 mm T.T. Toggle lever VFM250-02-08 Panel mounting hole T.T.
Refer to pages 15-18-3 to 4 for Safety Instructions and Common precautions on the products mentioned in this catalog, and refer to pages 15-1-10 to 11 for Precautions on every series. Min. bending radius (mm) 12 15 23 27 31 60 12 15 23 30 40 Operating temperature 20 to +60C (No freezing) Nylon 11, Nylon 12 Material Caution 1.
CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.
Spacer 10 Aluminum alloy Magnet 11 28 Series NCQ8 Compact Cylinder Single Acting, Single Rod Construction/Single Acting Spring Extend Without auto switch With auto switch Male thread !1 !2 r t y e u i !0 w q !3 !4 !5 o Auto switch Parts List Repair Parts: Seal Kit for Single Acting Spring Extend Remarks Description Material No. Bore size Kit no.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 11 12 Vacuum suction type Relief type (with specially treated sliding parts) CXSJM, CXSJL CXSJL CXS 6 50 J 11 L M9B S 21 CXS L J 6 50 M9B S Number of auto switches 2 pcs. 1 pc. n pcs.
Note 11) : For thread type: NPT only.
Nil S n G Rubber bumper only Cylinder stroke (mm) Rod end thread Nil F Male rod end Female rod end Model Cushion Bore size (mm) 20 25 32 40 20 25 32 40 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber 10-CM2X20 10-CM2X25 10-CM2X32 10-CM2X40 11-CM2X20 11-CM2X25 11-CM2X32 11-CM2X40 Relief type Vacuum suction type 1/8 25, 50, 75, 100, 125, 1/4 Non-lube Double
(Refer to page 11, [I/O cable] for details.) Note 3) The DIN rail is not included. If the DIN rail is required, please order separately.
SRF 1 07 11 0 S S 1 With nut Body size 1 3 5 Fitting type Pilot port thread type Made to Order (Refer to page 887 for details.)
Window of I/O Configurator (NFC version) 11 3.1. Basic characteristics 11 3.1.1. Login to administrator mode 13 3.2. Display for wireless master 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for wireless slave 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4.
Value x 0.01 (mA or V) 0 Value (-32767.. 32767 ) Lower limit AD value of Analog Range. 10 Lower Limit Value*1 True Output will be fault value. 11 Fault Mode Analog False Output will be held last state. Set output per channel when communication error is occurred.
) 1 1 [] -3No.PF-OMO0004CN-E () () () N2 () -4No.PF-OMO0004CN-E () * UL UL1310 2 UL1585 2 ,30[Vrms]42.4[V ] 2 UL , 100 N2 050 () JISB 8392-1 1.1.21.6.2 -5No.PF-OMO0004CN-E * FG (49 N () ,IN () () -6No.PF-OMO0004CN-E * 6 33 () 30 m DC(-)() -7No.PF-OMO0004CN-E * () () CE 050 -8No.PF-OMO0004CN-E * 10 /23% 3 * OUT * 23 -9No.PF-OMO0004CN-E PFMB 7 A*8 201 2~200L/min 8 2 (11
[%F.S.] 2 1 0 OUT OUT OUT OUT 0 D 2D 3D 4D 5D IN IN IN IN 0 1 2 3 4 5 5 (5D) [] [] LFE13/8 inch 0.2 MPa LFE23/4 inch LFE31 inch (mm) D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 68 No.LFE*-OMY0008 4.0 3.5 3.0 2.5 [%F.S.]
For air piping, use SMC tubing of diameter 8 mm or equivalent. 11. It is recommended to use supply air which purity class is 2:4:3 2:5:3 2:6:3 of ISO08573-1:2010JIS B8392-1:2012 or higher. The air containing mist or dust will cause the performance to decrease and shorten the maintenance cycle.
For air piping, use SMC tubing of diameter 10 mm or equivalent. 11. It is recommended to use supply air which purity class is 2:4:3 2:5:3 2:6:3 of ISO08573-1:2010JIS B8392-1:2012 or higher. The air containing mist or dust will cause the performance to decrease and shorten the maintenance cycle.
Mounting P 11 8. Environment P 11 9. Lubricant oil P 11 10. Air source P 11 -2 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Check for air leaks from the fitting and piping. (11) In case of air leakage from the interface, stop air supply and check the mounting condition of the gasket. Tighten the mounting screw with appropriate torque. If the countermeasures above are not effective, there may be a problem with the valve. In that case, stop using the valve immediately.
55 41 57 XLH-50 70 179.5 79 2 11 75 52 70 8 XL-OMY0003
5 10 []18 12 O 1) FKM M 10 FKM : 110 Pa <> 9 XL-OMY0003
6 6-1. 1 1P4P5 10 XL-OMY0003
6-2 1 2 b 3 1 2 O 4 a aa b O O
(Page 11) 6 - 2) Avoid having a large gap between the clevis or trunnion and mating bushing, as this exposes the pin to a bending load. 3) Do not let foreign matter such as cutting chips get into the product from the suction port. 4) Do not touch the cylinder during high speed and high frequency operation.
Nm (mm) 20 1.5 2.0 0.5 25 2.9 2.0 0.5 32 2.9 2.0 0.5 40 4.9 2.0 0.5 50 11.8 5.0 1.0 63 24.5 5.0 1.0 80 24.5 20.0 2.0 100 42.2 20.0 2.0 6 7 8 9 2-4. 1 2) 3 4 5 6 7 11 1 2 3 1.5~2 2 2. 12 2-5. ,AS 2-6. 2-6-1. CG5N 2-6-2. CG5A 11~2 2 31 4 5 6 7 13 2-6-3.