SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2A40F-25DMZ-V"

In the case of V arrangements, the side having the largest branches is considered to be the vertical side (at 12 oclock); the other side is either to the right or left of vertical as viewed from the threaded end of the fitting.

V 2-wire Refer to page 12-13-25 for solid state switch with pre-wire connector.

V 2-wire Refer to page 12-13-25 for solid state switch with pre-wire connector.

Load voltage Electrical entry Lead wire length (m) Auto switch model Electrical entry Indicator light Wiring (Output) Pre-wire connector Special function Applicable load In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Type Perpendicular 3-wire (NPN) 3-wire (PNP) Y59A Y69A IC circuit 5 V 12 V Y7P Y7PV Solid state switch 12 V Y59B Y69B 2-wire Relay, PLC Grommet Yes 24 V 3-wire (NPN) 3-wire (PNP) Y7NW

24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz 4/2 5/3 (A/B R1/R2) 3 position Closed center Double Single Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal VQ130 0.73 0.84 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258

Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: 8 A or less (including shorts), and When controlled by a circuit protector (fuse) with the following ratings: No-load voltage (V peak) Max. current rating 0 to 20 [V] 5.0 100 Over 20 [V] and up to 30 [V] Peak voltage value (2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply

(Element life check) Max. contact capacity: 10 VA AC, 10 W DC Rated contact voltage (max. operating current): 125 V AC (0.08 A), 30 V DC (0.33 A) Max. contact capacity: 10 W DC Rated contact voltage (max. operating current): 30 V DC (0.33 A) Pressure drop 0.1 MPa Symbol V: Degreasing wash, white vaseline Reed switch Reed switch Body/housing is degreasing washed.

(NPN) 3-wire (PNP) 2-wire IC circuit 5 V, 12 V 12 V Diagnostic indication (2-color indication) Auto switches marked with are produced upon receipt of order.

24 V or less 100 V 0 0.1 0.2 0.3 0.4 Pressure setting scale Maximum operating current and range 40 mA 50 mA 20 mA Impact resistance 30 G 14-4-21 4 Series ARM11A Flow Characteristics Condition: Inlet pressure 0.7MPa Condition: Inlet pressure 0.5MPa ARM11AA1-307 (One-touch fittings: IN 6, OUT 4) ARM11AA1-307-1 (One-touch fittings: IN 6, OUT 4) 0.35 0.6 0.7 0.30 Outlet pressure MPa Outlet pressure

or less (With load current of 80 mA) (PF2D300, PF2W300, PF2W330) Maximum applied voltage: 30 V 2 outputs Environmental resistance Note 4) Output specifications Switch output PNP open collector Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D301, PF2W301, PF2W331) 2 outputs NPN open collector or PNP open collector (Same as switch output) Accumulated

Wire core color For PSE200 (ZS-26-E) Brown (DC (+)) Black (OUT: 1 to 5 V) Blue (DC (-)) Not connected Connector no. 1 2 3 4 PF2 For PSE300 (ZS-28-C) Brown (DC (+)) Not connected Blue (DC (-)) Black (OUT: 1 to 5 V) IF Controller Data Handling Confirm that the numbers on the connector match the colors of the wires and that the wires are inserted to the bottom.

V J Rod Cross Sectioo Rod Cover Head Cover Head Cover uNrT rNcH (MM) 4srrc SERIES NCJ2K Non-rotating Piston Rod Type: Double Acting/Singte Rod I Rod Side Flange Type (F) nc.,zxrl6G!

CEP1 Adjustment dial Option CE1 With cancel cap With lever detection switch With lock mechanism V m/min CE2 Work W Work W Work W ON OFF ML2B Work W Work W Cancel cap Drag C J G5-S Lever detection switch CV Bracket MVGQ The cancel cap holds the lever horizontally allowing a pallet to pass.

Core wire colors M12 48 1 1 2 3 4 5 2 : DRAIN 6 5 Red: V+ Black: V 16 White: CAN H Blue: CAN L M12 4 3 14.9 Socket connector pin arrangement Connections Terminal no.

Lead wire length (m) Pre-wired connector Applicable load Load voltage Auto switch model Indicator light Wiring (Output) Special function Type Electrical entry DC 3 (L) 5 (Z) 2-wire Yes Water resistant (2-color indication) Solid state switch Grommet Relay, PLC H7BA 12 V 24 V Lead wire length symbols: 3 mL (Example) H7BAL 5 mZ (Example) H7BAZ Solid state auto switches marked with are produced

Core wire colors Brown: Not connected Note 1), 24 VDC 10% (Control power supply) Note 2) White: 24 VDC +10%/5% (Solenoid valve power supply) Blue: Not connected Note 1), 0 V (Control power supply) Note 2) Black: 0 V (Solenoid valve power supply) Gray: Not connected Brown: 24 VDC +10%/5% (Solenoid valve power supply) White: 0 V (Solenoid valve power supply) Blue: 24 VDC 10% (Control power

Thread Rc G NPT Nil None V V V A Yes 6 V B 1/4* V Z With light/surge voltage suppressor Port size Port size VP500 VP700 03 3/8" V 04 1/2" V * For internal pilot, the symbol is nil. * Refer to Piping for External Pilot Type on page 4 for selection of the check valve.

Material Diaphragm Poppet Body Brass Code Option B S SH Gauge port (Extra bottom outlete, Inletr, Outlett) 316 SS 316 SS Specification Standard (Cv: 0.09) High flow (Cv: 0.15) Code 316 SS Hastelloy C-22 Hastelloy C-22 No code HF Pressure gauge 1) Code Ports psig/bar unit MPa unitunit No gauge port Seat material Material Code S, SH V V V V V No code Ports No pressure gauge (Connections: 1/

Function Description 1 PWR1 24 V External power supply 1 24 V 2 PWR1 0 V3 External power supply 1 0 V 3 PWR2 0 V3 External power supply 2 0 V 4 PWR2 24 V External power supply 2 24 V 5 Not used 3 0 V signal lines of No. 2, No. 3, and the power supply for the valve on the SI unit side are internally connected.

to 2.5 A (240 V) 9 A (100 V) to 4 A (240 V) 10 A (100 V) to 4 A (240 V) 8 A (200 V) Power consumption 440 W1 850 W1 900 W2 1500 W2 Alarm Refer to Alarm.