Flow Rate: 4.2 CFM / 7.2 m3/hr / 119 LPM , 4.2 CFM / 7.2 m3/hr / 119 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .4, Voltage (60 Hz): 230, Voltage (50 Hz): 230, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.66 in / 220 mm Width: 5.98 in / 152 mm Height: 6.14 in / 156 mm
Flow Rate: 2.4 CFM / 4.2 m3/hr / 68 LPM , 2.4 CFM / 4.2 m3/hr / 68 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .2, Voltage (60 Hz): 200 - 277 / 346 - 480, Voltage (50 Hz): 200 - 255 / 346 - 400, Frequency (Hz): 50 / 60, Phase: 3-phase, Item Dimensions: Length: 8.07 in / 205 mm Width: 5.98 in / 152
Flow Rate: 7 CFM / 12 m3/hr / 198 LPM , 7 CFM / 12 m3/hr / 198 LPM, Max Pressure: 11.6 PSIG / .8 bar , 11.6 PSIG / .8 bar, Horsepower (60 Hz): .59, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Net Weight: 22.7 lbs. / 10.3 Kg Series Configured Datasheet.
Flow Rate: 5.6 CFM / 9.6 m3/hr / 159 LPM , 5.6 CFM / 9.6 m3/hr / 159 LPM, Max Pressure: 8.7 PSIG / .6 bar , 8.7 PSIG / .6 bar, Horsepower (60 Hz): .59, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 9.8 in / 249 mm Width: 6.14 in / 156 mm Height: 6.14 in / 156 mm , Length: 9.8 in / 249 mm, Width
Flow Rate: 7 CFM / 12 m3/hr / 198 LPM , 7 CFM / 12 m3/hr / 198 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .6, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Net Weight: 22.7 lbs. / 10.3 Kg Series Configured Datasheet.
Flow Rate: 5.6 CFM / 9.6 m3/hr / 159 LPM , 5.6 CFM / 9.6 m3/hr / 159 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .59, Voltage (60 Hz): 200 - 277 / 346 - 480, Voltage (50 Hz): 200 - 255 / 346 - 400, Frequency (Hz): 50 / 60, Phase: 3-phase, Item Dimensions: Length: 9.8 in / 249 mm Width: 6.14 in /
Indicator: S, Control Method: E (Meter-out), Stud Position: A (Right Side), Tube Diameter: 04 (ø4), Thread: R, Port Size: M3 (M3 x 0.5)
Series: JSY1 (1000 Series), Actuation: 1 (2-position, Single), Manifold Type: 20 (Body Ported), Power Saving Circuit: T (w/Power Saving Circuit), Electrical Entry: L (L Plug Connector w/Lead Wire, 300mm), Cable Length: None, Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size, Thread Piping: M3 (M3 x 0.5), PE Plate: PE
Series: JSY1 (1000 Series), Actuation: 2 (2-position, Double), Manifold Type: 20 (Body Ported), Power Saving Circuit: T (w/Power Saving Circuit), Electrical Entry: L (L Plug Connector w/Lead Wire, 300mm), Cable Length: None, Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size, Thread Piping: M3 (M3 x 0.5), PE Plate: PE
Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 2 Stations, P,E Port Entry: U (U Side), A,B Port Size: M3 (M3 x 0.5), Thread Size: N (NPT)
Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 3 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: M3 (M3 x 0.5), Thread Size: N (NPT)
Series: 1 (JSY1000), Type: 41 (Bottom Ported), Valve Stations: 9 Stations, P,E Port Entry: U (U Side), A,B Port Size: M3 (M3 x 0.5)
Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 7 Stations, P,E Port Entry: U (U Side), A,B Port Size: M3 (M3 x 0.5)
Series: 1 (JSY1000), Type: 40 (Side Ported), Valve Stations: 2 Stations, P,E Port Entry: D (D Side), A,B Port Size: M3 (M3 x 0.5)
Control Method: E (Meter-out, Gray), Stud Position: A (Right Side), Tube Diameter: 04 (ø4), Thread Type: R, Port Size: M3 (M3 x 0.5)
Control Method: E (Meter-out, Gray), Stud Position: A (Right Side), Tube Diameter: 23 (ø3.2, Use 1/8" Tubing), Thread Type: R, Port Size: M3 (M3 x 0.5)
Control Method: E (Meter-out, Gray), Stud Position: B (Left Side), Tube Diameter: 04 (ø4), Thread Type: R, Port Size: M3 (M3 x 0.5)
Control Method: E (Meter-out, Gray), Stud Position: B (Left Side), Tube Diameter: 23 (ø3.2, Use 1/8" Tubing), Thread Type: R, Port Size: M3 (M3 x 0.5)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 04 (ø4), Thread Type: R, Port Size: M3 (M3 x 0.5)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 23 (ø3.2, Use 1/8" Tubing), Thread Type: R, Port Size: M3 (M3 x 0.5)