6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140, 1.46975 lb, ModelApplicable valveManifold typeP(SUP), R(EXH)Valve stations Note)A, B port specificationsPort sizeManifold base weight W (g) n: StationsLocationDirectionP, R portA, B portSS5X3-45SX3 40Stacking type/DIN rail mountedCommon SUP/Common EXH2 to 20 stationsBaseSideC8 (One-touch fitting for ?
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140, 1.46975 lb, ModelApplicable valveManifold typeP(SUP), R(EXH)Valve stations Note)A, B port specificationsPort sizeManifold base weight W (g) n: StationsLocationDirectionP, R portA, B portSS5X3-45SX3 40Stacking type/DIN rail mountedCommon SUP/Common EXH2 to 20 stationsBaseSideC8 (One-touch fitting for ?
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140, 1.25387 lb, ModelApplicable valveManifold typeP(SUP), R(EXH)Valve stations Note)A, B port specificationsPort sizeManifold base weight W (g) n: StationsLocationDirectionP, R portA, B portSS5X3-45SX3 40Stacking type/DIN rail mountedCommon SUP/Common EXH2 to 20 stationsBaseSideC8 (One-touch fitting for ?
6)2 to 10 stations: W = 22n + 11811 to 20 stations: W = 22n + 140, 1.32277 lb, ModelApplicable valveManifold typeP(SUP), R(EXH)Valve stations Note)A, B port specificationsPort sizeManifold base weight W (g) n: StationsLocationDirectionP, R portA, B portSS5X3-45SX3 40Stacking type/DIN rail mountedCommon SUP/Common EXH2 to 20 stationsBaseSideC8 (One-touch fitting for ?
AD37 AD47 Polycarbonate Relieving type Note 1) Assembly includes a bracket and set nuts. Note 2) in part numbers of the round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for NPT. Contact SMC regarding the connection thread NPT and supply of the pressure gauge for PSI unit specifications.
Operating Note 3) 2-position 8-6:5, 8-8:6, 8-10:5 8-6:20, 8-8:15, 8-10:10 frequency cycle/sec. 3-position 8-6:3, 8-8:3, 8-10:2 8-6:10, 8-8:10, 8-10:20 Lubrication Not Required Manual override Non-locking push type Protection structure Dust Proof Coil rated voltage 100VAC, 110VAC, 200VAC, 220VAC, 24VDC Allowable voltage range % -15~ +10% of rated voltage Coil insulation Class B or equivalent
A Section A-A Bolt holder (movable) Approx. 0.5 or less 849 Dual Rod Cylinder/Compact Type CXSJ 2122CXSJ/ 1112Dimensions: 6 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F. R.
(No continuous voltage uctuation) Earth leakage breaker Rated current [A] 30 40 50 Sensitivity current [mA] 30 Rated operating current4 [A] 17 32 41 Rated power consumption4 [kW(kVA)] 5.4 (5.9) 10.5 (11.0) 13.1 (14.2) Noise level (Front 1 m/Height 1 m)4 [dB(A)] 75 75 71 Accessories Operation Manual (for installation/operation) 2 pcs.
(0100)() 90 () (0100) ()90ON(OFF) () 10 L/min 10 L ON OFF ON OFF 0 -14No.PF-OMO0004CN-E , , 2 5 10 L/min 5 ,51050 L ON-OFF () 1 L/min ,10 11 12 1 L/min SI SI ON-OFF ON 0 ripple -15No.PF-OMO0004CN-E AB.
controllers connected Controlled flow 112 27% DOWN 27% DOWN CyL A Lift side Current Free flow Four AS3001F-10 controllers connected with holders (TMH-10) Index plate (example with identification label attached) Holder Lightweight Flow rate characteristics are equivalent to the current product.
Description No. 2 Common IN Individual IN Common IN Individual IN Bonnet Polyacetal Regulator NARM2500-A-N02 NARM2500-B-N02 NARM3000-A-N03 NARM3000-B-N03 9 Regulator 1 Component Parts 10 End plate R 1 No.
Bore d C B H NTJ-015A 10 16 8.1 9.2 7 8 3.2 4 M4 X 0.7 NTJ-010A M5 X 0.8 * Refer to p.1.3-12 for details of the mounting nut. (mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.
Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.
possible (1 l/min) 10 1 to 10 l/min 4 With neon light (220 VAC, Green) 20 10 to 20 l/min Simple flow setting Without removing the cover, you can set with a screwdriver from the outside.
pressure differential (MPa) Av x 10 m Cv converted Max system pressure (MPa) Weight (g) PAX Water, Oil, Steam 2 -6 VXZ2362-10 0 0.7 0.6 0.7 0.6 0.7 0.6 290 12 215 1.5 1550 PB Note) Values for the grommet type.
10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 13 16 19 20 22 25 108 155 221 1/4, 3/8 3/8, 1/2 1/2, 3/4 3 Series AMP Model Selection Selection Caution Caution 1.
-11 Pam3/s 2 x 10-10 Pam3/s 1) 4 x 10-9 Pam3/s 1) Ra 10 in.(0.25 m) Face seal, Tube weld Bottom mount 0.06 in3 (1.07 cm3) 0.22 kg 2) Leak rate Across the seat leak Surface finish Connections Installation Internal volume Weight Knob 1/4 turn indicating round knob with a raised rectangular section 1) Tested with Helium gas inlet pressure 125 psig (0.9 MPa). 2) Weight for AZ3652S2PMV4MV4 including
Do not use a cable longer than 10 m. Wire the DC (-) line (blue) as close as possible to the power supply.
mounting hole 40 8.5 20 28 72.5 (when set = 75.5) Bleed exhaust hole 6.5 28 41 1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.