SMC Corporation of America
Elite Part Number Search
Search Results "25A-ISE20-P-M5-LB"

Mounting bolt M5 X 75l M5 X 85l M5 X 80l M5 X 90l M5 X 90l M5 X 100l M5 X 80l M5 X 90l M6 X 105l M6 X 135l M8 X 105l M8 X 135l D 75 85 80 90 90 100 80 90 105 135 105 135 Part No.

Operating pressure (MPa) U: Maximum speed (mm/s) Stroke (mm) Mode of operation Inclined operation Vertical operation Horizontal operation Review of load weight and operating pressure Lo Fn W Guide First tentative bore size determination F3 D1.6 x P First tentative bore size determination F2 D1.6 x P First tentative bore size determination F1 D1.6 x P WB Inclined operation W+WBWV PPV

port Applicable cable O.D. 4 to 6.5 MAX.10 71.5 78.5 71 Indicator light (Type DZ only) 67.5 59 32 17 2 2-4.5 (Mounting hole) P mPm P 19 35 Pg.7 2-Rc 1/8 1(P) port A A A 11 20 26 49 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc 1/8, M5 x 0.8 2(A) port 19 35 n-Rc 1/8 3(R) port 47.5 11 R R P = 19 19 L Dimension n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133

10 71.5 59 68 Applicable cord O.D. 4 to 6.5 Pg.7 29 mPm 27 50.5 58 63 25 2-3.5 (mounting holes) Manual override (non-locking) 27 0.5 0.5 P R 13.7 2-M5 x 0.8 (ports P, R) 24 See grommet type for other dimensions.

D1 M M A L1 D1 D2 L2 H Connection threads Male Branch: KPQU, KPGU (M5) Effective area mm D Model L TPH TPS A H (width across flats) (M5) 2-Applicable tubing Note1) Connection threads R Applicable tubing O.D. mm Weight g M P P M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 KPQU04-M5 KPQU04-01 KPQU04-02 KPQU06-M5 KPQU06-01 KPQU06-02 KPQU08-01 KPQU08-02 KPQU10-02 KPQU10-03 KPQU12-03 KPQU12-04

x 0.8 7.5 2.5 6 4 5.5 3 38 23 15.5 10.5 40 4.5 9.5 33h9 34 h9 17H9 5.3 2.5 4.2 10 4.2 4.5 M5 x 0.8 M5 x 0.8 7.5 2.5 6 5 5.5 7 45 30 18.4 12.2 50 5 7 39h9 40 h9 20H9 6.5 2.5 4.5 11.5 4.2 4.5 (mm) JK P M3 x 0.5 M3 x 0.5 M3 x 0.5 M5 x 0.8 PA M3 x 0.5 M3 x 0.5 M3 x 0.5 M5 x 0.8 S WD M3 x 0.5 M3 x 0.5 M3 x 0.5 M4 x 0.7 JJ M3 x 0.5 M3 x 0.5 M3 x 0.5 M4 x 0.7 JU M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x

1 (IN), 2 (OUT) port 2 x M5 Thread depth N B 2 x P 1 (IN), 2 (OUT) port 2 x M5 Thread depth N K K J H J H Conduit terminal DIN terminal F Cable 6 to 12 Q D D S G1/2 Qp2 F 34 (44) 31.5 32 R 25 T C K C R E E Sp2 A A B1 2 x P 1 (IN), 2 (OUT) port B1 2 x P 1 (IN), 2 (OUT) port B B 2 x M5 Thread depth N 2 x M5 Thread depth N K J H J H G1/2 (mm) Grommet Grommet (with surge Dimensions Size Port

Fittings & Tubing Air Cylinders Rotary Actuators 12 12.5 5.5 12 6.3 26 Operating port 2 x M5 x 0.8 Other dimensions are the same as basic type. 804 MXQ 1322Air Slide Table Basic Dimensions: MXQ8 13222 x M3 x 0.5 thread depth 4 Operating port 2 x M5 x 0.8 2 7 3.5 I J Vacuum suction port M5 x 0.8 8 Max. 11 (Retraction end adjuster) 5.5 4 6.5 Note 1) If long bolts are used, they can touch the

Plug Part Number Bore size Part number Port thread type Quantity1 12 (10 x 2) 16 (12 x 2) P-M3 M3 8 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) P-M5 M5 8 P-R1 Rc1/8 8 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) P-N1 NPT1/8 8 P-G1 G1/8 8 P-R2 Rc1/4 8 80 (56 x 2) 100 (71 x 2) P-N2 NPT1/4 8 P-G2 G1/4 8 *1 1 set includes 8 pieces.

D1 M M A L1 D1 D2 L2 H Connection threads Male Branch: KPQU, KPGU (M5) Effective area mm D Model L TPH TPS A H (width across flats) (M5) 2-Applicable tubing Note1) Connection threads R Applicable tubing O.D. mm Weight g M P P M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 KPQU04-M5 KPQU04-01 KPQU04-02 KPQU06-M5 KPQU06-01 KPQU06-02 KPQU08-01 KPQU08-02 KPQU10-02 KPQU10-03 KPQU12-03 KPQU12-04

(Non-locking) Manual override 69.4 (30.5) 24 13.5 2-6.5 (For mounting) (X port) (M5 x 0.8) (R port) Rc 1/4 101.6 26.7 (17.5) 3(R) 1(P) 3(R) 1(P) 3(R) 1(P) 3(R) 27 50 V100 1(P) MAX.10 D: 112.8 26.7 Y: 112.3 101.6 102.4 MAX.10 112.8 (P port) Rc 1/4 SY SYJ 300 (Pitch) Pg9 Pg9 85.6 95.6 27.5 28 (Lead wire length) 95.1 105.1 Y: 97.6 114.6 L1 L2 7.5 90.1 100.1 D: 95.6 112.6 Applicable lead wire

D1 M M A L1 MS D1 D2 T L2 H VMG Connection threads Male Branch: KPQU, KPGU (M5) H (width across flats) Effective area mm2 D Model L TPH TPS A (M5) 2-Applicable tubing Note1) Connection thread R Applicable tubing O.D. mm Weight g M P P M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 KPQU04-M5 KPQU04-01 KPQU04-02 KPQU06-M5 KPQU06-01 KPQU06-02 KPQU08-01 KPQU08-02 KPQU10-02 KPQU10-03 KPQU12-03

Sensors (R) (P) 7.4 3 (13) M plug connector (M) L plug connector: 10-VQD1151-L-M5 M plug connector: 10-VQD1151-M-M5 5 5 5.5 2(B) 4(A) Direct manual override Lead wire length 300 mm 27 Indicator light 17.6 11.2 3 3(R) 9 0.3 3.8 10.9 3.5 5.5 9.1 2 x mounting hole 33.5 28.5 37 38 1(P) 1(P) 5.5 12 4-M5 x 0.8 13 L plug connector (L) (P, A, B, R port) 49 50.5 M plug connector (M) 598 4 Port Direct

Sealant/Gasket seal P.554 P.667 P.554 P.554 M/UNF/R/NPT More space beneath the tube. Easier installation/removal of the tube.

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m)

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)