GKM35-54 32 40 50/63 80/100 125 160 Piston rod ball joint KJ (DIN 648) Steel, zinc chromate plated Bore (mm) Ref. d3 d1 h d6 b3 b1 L d7 L3 M10 X 1.25 M12 X 1.25 M16 X 1.5 M20 X 1.5 M27 X 2 M36 X 2 10 12 16 20 30 35 43 50 64 77 110 125 28 32 42 50 70 80 10.5 12 15 18 25 28 14 16 21 25 37 43 20 22 28 33 51 56 19 22 27 34 50 58 13 13 15 15 15 16 14 16 26 26 35 41 KJ10D KJ12D KJ16D KJ20D KJ27D
Stainless steel type: White Note 2) White is also used for inch size. Applicable tubing O.D. Note 1) Metric size 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Inch size Note 3) 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Indicator window direction Elbow Universal Note 1) For selecting applicable tubing O.D., refer to the Model on page 687. Note 2) Use 1/8" tubing.
-16 1.7.4 Label . 1-16 1.8 Material Safety Data Sheet (SDS) . 1-16 1.8.1 Galden HT135 . 1-17 1.8.2 FluorinertTM FC-3283 . 1-29 1.8.3 Galden HT200 . 1-38 1.8.4 FluorinertTM FC-40 . 1-50 1.8.5 Ethylene glycol aqueous solution 60% . 1-58 1.8.6 Refrigerant R410A . 1-64 1.8.7 Refrigerant R448A . 1-76 Chapter 2 Name of Each Section . 2-1 2.1 Name of Each Section (1) . 2-1 2.2 Name of Each Section
CN1B SW2 Note 7) Cap Note 8) Cable Cable length Cable model 1 2 LE-CSS-; SSCNET III optical cable 0.15 m to 3 m Note 6) Connections from Axis 2 onward are omitted. Note 7) Up to 16 axes can be set.
M 10 16. 16-1. 1 22 (mm) gfcm) (mm) 12 RTW-13 5 14 16 RTW-18 6 34 20 RTW-22 8 52 25 RTW-26 10 88 32 RTW-34 14 220 40 RTW-42 14 220 50 RTW-52 17 440 63 RTW-62 17 440 80 RTW-82 22 1,240 100 RTW-102 27 2,000 16-2. 1) 1 1 2) 2 2 11 3) 32 4) 3 3 16-3. 2JIS2 1 , 4 2 3 4 16-4. 1 5 5 6 6 12 () 32 () 32 7 7 () 8 2 1 13 17. 17-1.
DXT170-176-2-01 DXT170-176-2-02 DXT170-176-2-03 DXT170-176-2-04 DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 For Series VZ300/500 With light/surge voltage suppressor With surge voltage suppressor 100 VAC 200 VAC 110 VAC 220 VAC 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC S E For VZ120 Indicator light is not available for grommet type.
Actuator side Controller side (14.2) (2) 1 2 (5.5) (14) (1) B1 A1 5 6 (17.7) (3) 2 1 A6 B6 (18) (6.3) 15 16 L (11) (30.7) 12 - [3] Actuator cable for actuator with lock (for sensor and lock) [5m or less] LE CP B (1) (2) Signal name Terminal No. Cable color Terminal No.
About this product Option/Part number Joint screws (2 screws, 2 spacers , 2 nuts) ISA-16Bracket (when control unit not fitted) (Nominal size:3 x 8, 3 screws) ISA-14 Number of stations Part number 2 ISA-16-2 3 ISA-16-3 4 ISA-16-4 5 ISA-16-5 6 ISA-16-6 With connector lead wire ZS-31-B With connector lead wire ZS-31-C : Spacers are included for 4 and 6 stations.
(same side) (n 4) 2 (n 4) 2 25 + 55 135 + 55 125 + 55 BT-12 BT-12 BT-16 F5W/J59W/ F5BAL/F5F n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 2 pcs.(different side, same side), 1 pc. D-F5W, J59W D-F5BAL D-F59F D-F5NTL 155 35 145 D-A3/A4/G39/K39 BS1-125 BS1-140 BS1-160 (n 4) 2 (n 2) 2 (n 4) 2 155 + 55 35 + 55 145 + 55 "n" pcs.
For 3 stations For remote I/O A1W DeviceNet PROFIBUS-DP CC-Link 16 For 16 stations A2W 0 Without SI unit Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) Note 1) Double wiring specifications 08 02 8 stations 2 stations Note 2) Supply/Exhaust block assembly specification Specified
Type Metric size Inch size Elbow Universal 2 3 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 23 3.2 4 6 8 10 12 03 05 07 09 11 13 04 06 08 10 12 Control type Meter-out Meter-in 0 1 Use 1/8" tube.
seal Tube gasket O-ring 37 19 30 31 32 35 Special resin NBR NBR NBR NBR NBR 2 2 2 2 2 2 MYH25-15BK2902B MYH32-15BK2903B MYH40-15BK2904B MY1H32-PS MY1H40-PS MY1H25-PS Seal kit includes !
25 ISO Standard Solenoid Valve: Size 2 Metal Seal/Rubber Seal Series VQ7-8 Prewired Connector Type 2 position single : VQ7-8-FG-S-SC single (Reverse pressure): VQ7-8-YZ-S-SC 154 154 71.5 82.5 82.5 56(71) 56(71) 49(64) 49(64) 16(20)(B port) 16(20)(A port) 31(42) 31(42) Mounting hole 2-7.5 P R2 R1 VK Manual override A B PB (11) 10 12 (16) 16 (23) (22) 16 VZ 62(72) 75(86) 62(72) 75(86) 50 A
rw 00h 6300 ARRAY Write Outputs 16-bit 0 VAR Number of outputs 16-bit Unsigned8 ro 1 VAR Write Outputs 1h to 16h Unsigned16 rw 0h 2 VAR Write Outputs 17h to 32h Unsigned16 rw 0h 6306 ARRAY Error Mode Outputs 16-bit 0 VAR Number of outputs 16-bit Unsigned8 ro 1 VAR Error Mode Outputs 1h to 16h Unsigned16 rw Fh 2 VAR Error Mode Outputs 17h to 32h Unsigned16 rw Fh ro = read only access rw =
(mm) TLM0201 2 x 1 2 1 TLM0302 3 x 2 3 2 TLM0425 4 x 2.5 4 2.5 TLM0403 4 x 3 4 3 TLM0604 6 x 4 6 4 TLM0806 8 x 6 8 6 TLM1075 10 x 7.5 10 7.5 TLM1008 10 x 8 10 8 TLM1209 12 x 9 12 9 TLM1210 12 x 10 12 10 TLM1916 19 x 16 19 16 TLM2522 25 x 22 25 22 TLM1613 16 x 13 16 13 Length per roll Color Translucent Translucent Symbol N N R BU B N N N 10 m Red (Translucent) 20 m Blue (Translucent) Roll
Steel 1300 Series VFR5000 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Plug-in: 2 Position Single/Double, 3 Position Closed Center/Exhaust Center/Pressure Center 2 position single: VFR510 -F(Z) 0 1 21 [25] 32 [39] 40 [40.5] 31 [36] 31 [36] 25 [24] 1 2 31 [41] 16 [19.5] 16 [19.5] EA P EB SJ A B 32 [39] 40 [40.5] SY 5 x 3/8, 1/2, 3/4 EA, EB port = 1/2 in case of 3/