SMC Corporation of America
Elite Part Number Search
Search Results "VV3P5-41-121-03N"

Model Port size Effective area (mm2) Weight (g) ANB1-01 22 81 25 18 35 93 30 21 94 107 46 24 175 133 50 41 462 190 74 41 612 230 74 60 871 271 86 70 A B C Dimensions (mm) 1 8 ANB1-02 15 10 51 22 1 4 ANB1-03 35 3 8 ANB1-04 60 1 2 ANB1-06 90 3 4 ANB1-10 160 1 1 1 ANB1-12 280 1 4 ANB1-14 450 1 2 610 Construction/Parts/Dimensions ANB1-01 to 04 JIS symbol ANB1-04: PP ANB1-06 to 14 How to Order

93 36.5 13.5 15 32 25 23 M5 24 59.5 46 57.5 60 55 48.5 101 57.5 68 1/2 22 45 96.5 41 11 17 36 22.5 23 M5 26 65 48 63 62 60.5 50.5 103 63 70 1/4, 3/8 VCW42 30 50 101 41 13.5 17 36 25 23 M5 26 67 48 65 62 62.5 50.5 103 65 70 1/2 35 60 108.5 41 17.5 17 36 30 28.2 M5 26 70.5 48 68.5 62 66 50.5 103 68.5 70 3/4 5 Series VCW How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C

For nozzle size 10, 13, 15 + with function plate M3 x 0.35 x 93 4 6 6 6 6 For nozzle size 10, 13, 15 For nozzle size 18, 20 For nozzle size 10, 13, 15 + with function plate For nozzle size 10, 13, 15 + with function plate M3 x 0.35 x 37 M3 x 0.35 x 41 M3 x 0.35 x 42 M3 x 0.35 x 46 !0 Precautions Components Ejector unit Be sure to read before handling.

High precision type High precision type High precision type High precision type Ta = I (Nm) Basic type Basic type Basic type Basic type I: Inertial moment 1 2 3 7 10 20 30 50 70 100 200 31 41 0.56 41 Refer to page 3. 32 45 0.82 45 . : Angular acceleration Load . 33 48 1.1 48 2 = (rad/s 2) t 2 54 71 1.5 71 : Rotation angle (rad) 86 74 107 2.9 78 74 2.4 78 t: Rotation time (s) 166 137 197

93 36.5 13.5 15 32 25 23 M5 24 59.5 46 57.5 60 55 48.5 101 57.5 68 1/2 22 45 96.5 41 11 17 36 22.5 23 M5 26 65 48 63 62 60.5 50.5 103 63 70 1/4, 3/8 VCW42 30 50 101 41 13.5 17 36 25 23 M5 26 67 48 65 62 62.5 50.5 103 65 70 1/2 35 60 108.5 41 17.5 17 36 30 28.2 M5 26 70.5 48 68.5 62 66 50.5 103 68.5 70 3/4 4.5-7 Series VCW How to Order Manifolds How to Order Manifold Assemblies (Example)

51 37 41 50 41 45 57 42 43 53 72 78 12.5 15.9 12.5 15.9 13.6 17 15.8 19.2 19.6 20.9 21.3 24.5 20.9 21.3 24.5 20.9 21.3 24.5 20.9 21.3 24.5 24 27.2 13.8 15.6 13.8 15.6 16 17.8 20.4 2.5 4 1.6 1.8 8 5 10 13.5 3 4 2.6 2.3 Applicable tube L1 M 6 4 6 10 5.8 10 15 3.3 H1 12 d 6 8 14 6.6 12 5.3 17.4 16 22.2 A L2 23 H2 25.6 10 7.5 6.8 26 Connection thread 27.5 17 7.6 15 20.9 27 25.6 8 10 7.3 30 27.5

For the indicator lighted style, be careful not to damage the light with the lead wire of the cable. 41 Series VXZ Specific Product Precautions 6 Be sure to read before handling. Refer to back cover for Safety Instructions, Handling Precautions for SMC Products (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves for Fluid Control Precautions.

If using other screws, the switch may be damaged. 0.5 8 8 7 1 14 14 13 Lead wire length (m) 3 41 41 38 5 68 68 63 Auto Switch Internal Circuit D-M9N(V) Dimensions Unit: mm DC (+) Brown D-M9 Indicator light Switch main circuit Switch main circuit Switch main circuit SMC D-M9B OUT Black M2.5 X 4 long Slotted set screw 3.2 2.7 22 DC () Blue 2.6 D-M9P(V) DC (+) Brown 6 Most sensitive position

Changing PD04 from 00212100 to 0021210D 0 D 41 - (2) Symbol allocation using the setup software: Changing pins CN1-16 to Gain changing selection (CDP). Change PD04 from 00212100 to 0021210D in the I/O tab. Select Single Axis Write. Cycle the power the parametersto be enabled.

) 36 (33) 66 0.5 59 (54) 52 (49) 41 (39) 79 0.1 0.2 4 0.3 40 (30) 37 (29) 31 (23) 54 2) 46 (37) 49 (44) 41 (36) 68 0.5 63 (57) 57 (51) 46 (43) 82 0.1 0.2 6 0.3 43 (34) 39 (30) 35 (28) 54 2) 49 (41) 53 (50) 47 (43) 68 0.5 67 (64) 61 (59) 54 (51) 81 1) ( ) 2) ZQ05A0.35MPaZQ07AZQ10A0.43MPaZQ000A0.4MPa 3) (PD) V PD [MPa] ZQ05A ZQ07A ZQ10A ZQ000A 0.05 11 10 8 16 0.15 22 20 17 32 3.2 0.25

M L K J H E t W1 W2 M 14 20 25 29 37 49 58 69 89 100 117 136 14.5 20.5 24.5 30.5 36.5 48.5 6 7 7 9 9 10 11 16 21 24 32 41 10 17 22.5 24.5 27 30 16 21 26 32 41 50 17 24 28 36 43 55 8 8 8 8 13 13 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3P1A LQ3P2A LQ3P3A LQ3P4A LQ3P5A LQ3P6A 1/4 (E) (E) L Panel Aperture (K) Straight Union : LQ3U (mm) Inch Size H Model Tubing O.D.

93 36.5 13.5 15 32 25 23 M5 24 59.5 46 57.5 60 55 48.5 101 57.5 68 1/2 22 45 96.5 41 11 17 36 22.5 23 M5 26 65 48 63 62 60.5 50.5 103 63 70 1/4, 3/8 VCW42 30 50 101 41 13.5 17 36 25 23 M5 26 67 48 65 62 62.5 50.5 103 65 70 1/2 35 60 108.5 41 17.5 17 36 30 28.2 M5 26 70.5 48 68.5 62 66 50.5 103 68.5 70 3/4 5 Series VCW How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C

Features .pages 4-5 Preferred Options Guide.page 7 Q Q Base Mounted Valves and Manifolds.page 9 Specifications.pages 10-11 How To Order .pages 12-15 Options .page 16 Q Q Q Body Ported Valves and Manifolds .page 17 Q Specifications.pages 18-19 How To Order .pages 20-23 Options .page 24 Q Q Technical Reference .page 25 Q Dimensional Drawings.pages 26-39 Operations Guide .pages 41

Port locations: Axial direction CRBUWl-lSE (mm) A B C D E(g6) F(h9) G H J K L M N P Q1 (Depth) Q2 R S1 S2 T U V W X Model 10.5 8.5 10.5 11 11.5 14 12 15.5 10.5 9.5 10.5 10 11 13 13 14 CRBUW10-lS CRBUW10-lSE CRBUW15-lS CRBUW15-lSE CRBUW20-lS CRBUW20-lSE CRBUW30-lS CRBUW30-lSE M3 (4) M5 X 0.8 M3 X 0.5 M5 X 0.8 M3 X 0.5 4 -0.004 -0.012 9 0 -0.043 29 22 14 8 3 25 31 41 15.5 M3 X 0.5 5 24 3.5

range [mm] R OA OB PA PB Q S T U PC W X Y Without lock With lock Without lock With lock Motorless 25 15 to 100 8 37 38 15.4 8.2 28 46 92 1 15.4 123 173 145 195 51 101 to 400 LAT 32 20 to 100 10 37 38 15.4 8.2 28 60 118 1 15.9 123 173 150 200 61 101 to 500 LZ [mm] Body Bottom Tapped Size Stroke range [mm] MA MB MC MD MH ML MO MR XA XB LC3F2 15 to 39 24 32 50 M5 x 0.8 6.5 4 5 40 to 100 42 41

Weight (g) D-M9P(V) D-M9B(V) D-M9N(V) Auto switch model 0.5 m (Nil) 8 7 1 m (M) 14 13 Lead wire length 3 m (L) 41 38 5 m (Z) 68 63 Dimensions (mm) D-M9 D-M9V Mounting screw M2.5 x 4 L Slotted set screw (flat point) 500 (1000) (3000) (5000) Indicator light 2.6 3.95 Mounting screw M2.5 x 4 L Indicator light 2.8 Slotted set screw 2 7.5 0.3 22.8 2.6 15.9 4.6 2.8 2.6 19.5 2.6 6 Most sensitive

230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C) IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFB15E IDFB22E IDFB37E IDFB55E IDFB75E NPT3/8 10(17) 11(19) 12(20) ZFC NPT1/2 15(25) 16(27) 17(28) 25(43) 26(45) 28(47) SF 100F (37.8C) 100psi (0.7MPa) NPT3/4 41

9.3 19.2 47 (48) AS321FS-02-08 (S) 8 13.2 22.7 33 14.2 AS321FS-02-10 (S) 10 15.9 26.7 37 35.7 15.6 38 (39) AS321FS-02-12 (S) 12 18.5 29.7 40 34.5 17 50 (51) AS321FS-03-06 (S) 6 1/4 19 16.6 13.3 10.4 21.8 32.1 28.7 55.4 54 50.2 48.8 24.5 28.5 9.3 19.2 38 (39) AS321FS-03-08 (S) 8 13.2 22.7 33 14.2 AS321FS-03-10 (S) 10 15.9 26.7 37 28 15.6 29 (40) AS321FS-03-12 (S) 12 18.5 29.7 40 26.8 17 41

D d H Part no B C 30 M22 X 1.5 26 8 26 SOR-20 20 15.0 12.5 M8 X 1.25 5 13 NT-02 20 36.9 M24 X 1.5 32 8 32 SOR-25 25 19.6 16.5 M10 X 1.25 6 17 NT-03 25/32 43.9 M30 X 1.5 38 9 38 SOR-32 32 25.4 21.0 M14 X 1.5 8 22 NT-04 40 47.3 M33 X 2.0 41 11 41 SOR-40 40 4.10-6 High Power Cylinder Series RHC How to Rotate the Relief Valve Body The relief adjustment screw can be placed in any direction by

A 152.5 154 B 52.5 54 E 52 64 I 69 86 J 5 7 M 40 50 N 5.5 6.6 O counterbore 9 depth 7 11 depth 8 T 44 56 Z 14 19 W 66 80 U 35 41 Bore size (mm) 40 50 Data Note 1) Dimensions without auto switch are the same as drawing above. Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.