This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL 12VDC, VALVE, SYJ3000 SOL VALVE 4/5 PORT, 2D, SYJ3000 NO SIZE RATING, .12904 lb
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
pressure: 0.8MPa), Cv factor: 2 position metal seal 0.15; 2 position rubber seal 0.2 3 position metal seal 0.11; 3 position rubber seal 0.15, Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position 15 or less; 3 position 25 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, SOL, VALVE, VQ0 SOL VALVE 4 WAY, AD, VQ0 BODY PORT M5
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm
Series SY offers major advances in valve performance for cost-effective solutions to your requirements. The series offers high flow with low power consumption in a compact design. The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, COMPACT, LATCHING, VALVE, VQ100 SOL VALVE 3-PORT, AA, VQ100 BODY PT .02777 lb, .02777 lb
Port size Body size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Metric size Inch size 3.2 to 12 1 to 4 M5 to 1/2 1/8" to 1/2" Refer to the Web Catalog for details.
Rz 12.5 45 Female thread size Chamfered dimension D (Recommended value) M5 5.1 to 5.4 10-32UNF 5.0 to 5.3 2. Use G external threads with G internal threads. D For Uni Thread 45 Tightening method 1.
Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. Modification of the detecting position should be made in the state of 3. Auto Switch Mounting Bracket Part No.
33.5 7 5.5 5.5 5 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 26.5 22 20 20 51 42.5 34.5 30 181 159 146 146 M26 x 1.5 M26 x 1.5 M20 x 1.5 247 217 204 200 1/8 40 32 25 20 24 22 22 18 26-0.033 0 1/4 1/8 1/8 16 13 13 26-0.033 0 32-0.039 0 8 10 M32 x 2 1011Axial foot (L): RECL G H G F Width across flats B2 A K 2 x P (Rc, NPT, G) NA AL F Width across flats B1 H1 2 x NN Standard port Relief port M5
female thread M5 x 0.8 OUT IN OUT Thread type Nil N Rc NPT OUT IN OUT Note 1) Use caution not to tighten excessively when mountinga pressure gauge, otherwise it may result in a breakdown.
Body fixed A Maintenance Warning L Model Screw size Max. tightening torque [Nm] A [mm] L [mm] LEFl16 M3 0.6 3.5 20 LEFl25 M4 1.5 4.5 24 LEFl32 M5 3.0 5.5 30 LEFl40 M6 5.2 6.6 31 Maintenance frequency Perform maintenance according to the table below.
Applicable Model Model AR10 Port size M5 AR 10 X406 M5 A 0.4 MPa setting w q Option/Semi-standard: Select one each for a to f. Option/Semi-standard symbol: When more than one specification is required, indicate in alphabetic order.
Port size Body size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Metric size Inch size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Flow rate 0 5 10 Number of needle rotations Refer to the Web Catalog for details.