Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -39No.PS-OMV0009-E [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -37No.PS-OMY0007-A [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
DFSIIWDJ59W> lmm) DA59W DF5BA:DE5NT (mm) DF5BA A B A B A .B A B A B , 32 0.5 0 4.5 2 7 4.5 11 8.5 12 9.5 , 40 0.5 0 4.5 2 7 4.5 11 8 .5 12 9.5 , SO 1 0 5 2.5 7.5 5 11 .5 9 12.5 10 Ht H~ HI Hs 32 24.S 35 25 32.5 t 40 27.S 38.5 27.5 36.5 I SO 34.5 43.5 34 41 ; 80 4 2.5 6 6 .5 10.5 9 14.5 13 15.5 14 , 100 4 2.5 8 6.5 10.5 9 14.5 13 15.5 14 J 63 39.5 46.5 39 46 '. 63 1 0 5 2.5 7.5 5 11 .5 9 12.5
This item is U n i t N u m b e r M O D E < 0 applicable only when multiple units are used. 2. Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
R U V W Y Z B B B B B B B AWM20-D 30 34 43.9 5.4 15.4 55 2.3 29.7 28.5 14 6 117.9 104.4 100.4 106.9 AWM30-D 41 40 46 6.5 8 53 2.3 31.3 38.5 19 7 157.1 123.9 122.2 117.8 122.3 137.8 142.3 AWM40-D 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 186.9 155.6 153.9 149.6 154.1 169.6 174.1 The dimension C is the length when the filter regulator knob is unlocked. -40- 13-2.
R U V W Y Z B B B B B B B AWD20-D 30 34 43.9 5.4 15.4 55 2.3 29.7 28.5 14 6 117.9 104.4 100.4 106.9 AWD30-D 41 40 46 6.5 8 53 2.3 31.3 38.5 19 7 157.1 123.9 122.2 117.8 122.3 137.8 142.3 AWD40-D 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 186.9 155.6 153.9 149.6 154.1 169.6 174.1 The dimension C is the length when the filter regulator knob is unlocked. -40- 13-2.
C () White Reset (Vacuum suspension) B DC negative common Lead wire colors Set (Vacuum generation) Simultaneous energization protection circuit COM. (+) Red () Black SOL. A C (+) White Reset (Vacuum suspension) B AC type Lead wire colors 100 VAC, 200 VAC Set (Vacuum generation) Yellow Yellow A 3.
Option Symbol and Composition Option Symbol and Composition Main body, shading coil material Holder material (in core ass'y) Option symbol Seal material Coil insulation type Main body, shading coil material Standard A B D E F G H J L N P T X Option symbol Seal material Coil insulation type NBR FKM Standard A B D E F G H J L N P T X NBR FKM B Polyacetal B FKM EPDM Brass or BC6, Copper FKM
VX B 1 2 1 2 VX3 A VXA B NL R VN R LED B NL: Neon light R: Resistor LED: Light emitting diode R: Resistor LVC Caution LVA Valve Mounting After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque (0.2 to 0.23 Nm).
Note2) A (set) side energization : A light (orange) illuminates, B-(reset) side energization : B light (green) illuminates.
Power supply 24 VDC B B B Ground with a ground resistance of 100 or less without connecting the DC1 () lead (Blue) of the power supply cable to the power supply 0 V. Red A A +24 V Black Blue Charged object Charged object 0 V Reduced-wiring Fieldbus System F.G. (mm) Ground with a ground resistance of 100 or less. A B When using the autobalance sensor (body-mounting type) 10 20 20 40 3.
(2) Conversion formula from the measurement value to the process data: (PD) = (Pr b) / a Pr: Measurement value and directive value PD: Measurement value (process data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Applicable products Unit Range Inclination a Intercept b 4 L/min 0.004 0 16 L/min 0.016 0 L/min 40 L/min 0.04 0 100 L/min 0.1 0 250 L/min 0.25
Refer to page 7-2-5. 2-M3 x 0.5 (Port size) M3 x 0.5 (Relief port: 10See above) (Vacuum port: 11See above) 3.5 20Data C + Stroke 3 B + Stroke A + Stroke Without auto switch With auto switch A B C A B C Bore size (mm) 24 18 29 23 11.5 16.5 6, 8, 10 7-2-7 7 Series CUJ Construction Double acting !3 w e q !1 r y o e t !
Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: C (EPR Seal), Body Material: S (Stainless Steel Body), Pilot System Option: Standard, Thread: Rc(PT), Port Size: 15A (1/2), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal)
Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: C (EPR Seal), Body Material: S (Stainless Steel Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: G (Grommet)
Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: C (EPR Seal), Body Material: S (Stainless Steel Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 10A (3/8), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet)
Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: C (EPR Seal), Body Material: S (Stainless Steel Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal)
Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: C (EPR Seal), Body Material: S (Stainless Steel Body), Pilot System Option: Standard, Thread: F (G(PF)), Port Size: 15A (1/2), Voltage: 5 (24VDC), Lead Wire: GS (Grommet w/Surge Suppressor)
Size: 2 [ø15(ø11)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: EPR Seal, Body Material: Stainless Steel Body, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 1/2, Voltage: 24VDC, Lead Wire: DIN Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliance: -