SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S31-12-M3"

Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 2 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tithe screw (4x14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.

A 72 27 B 41.8 15.8 SFD100-02 23 Hole shape for bracket mounting 26.2 SMC 23 14.7 90 1.5 3 51 17 Use a countersunk head screw (M3) for bracket mounting. 72 27 3.5 SFD200-C SFD200-C Dimensions Model A 125 B SFD200C08 C10 C12 8 10 126 12 126 SMC 42 24 Bracket mounting dimensions 96.5 36 4 x 3.5 114.5 4 x 7 Applicable tubing O.D.

Dimensions L A LA Attached from top W C PA MM Note 1) M F HB HA Note 2) Attached from bottom: MD R Body B (mm) Note 1) Note 2) B C F HA HB L LA MM MD M PA R W A Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 16 35 6.5 5.5 16.5 23 57 25 M4 x 0.7 M3 4 25 6 36 18 36 6.5 5.5 17 23.5 66 30 M4 x 0.7 M3 4 27 6 37 20 46 8.0 5.5 21 28.5 70 30 M5 x 0.8 M4 5 36 7 47 22.5 60 9.5 6.0 27.5 36 80 35 M6 x 1.0

SET 12 Series PSE Operation : Special Setting 3 Auto shift Refer to C Auto shift function on page 14 for details.

Use the attached mounting screw (M3 x 0.5 x 14) for mounting. The mounting screw (M3 x 0.5 x 7) attached to the digital pressure switch assembly will not be required. Note 6) Assembly of a bracket and 2 mounting screws Note 7) Please consult SMC regarding the set nuts for the AW60(K). Note 8) Minimum operating pressure: N.O. type0.1 MPa; N.C. type0.1 MPa (AD27) and 0.15 MPa (AD37/47).

to 24 VDC Series PF2D5 RESET SET PF2D300-A(-M) Panel fitting dimensions 3 x 7.2 (=21.6) 8-M3 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black Main circuit 1 2 3 4 7 3 Load +0.5 0 Brown + 6 2 19.4 Blue 5 1 12 to 24 VDC 5 6 7 8 Series PF2D5 PF2D301-A(-M) The applicable panel thickness is 1 to 3.2 mm.

is not provided for the 12 VDC specification.

(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Accessories Hexagon socket head cap screw (M3 x 30): 2 pcs. Connects the SI unit and the valve manifold. Seal cap: 1 pc.

Round head screw (M3 x 8) , 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6) , 2 pcs. Round head screw (M3 x 8) , 4 pcs. (2) End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20) , 1 pc. P tight screw (4 x 14) , 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.

Series NCY3B Series NCY3B6 Piping port M3 0.12 inch NN Piping port M5 S + Stroke ZZ + Stroke Nine bore sizes ranging from 6 mm (1/4") to 63 mm (2-1/2") are available. Broad range of made-to-order options. Note) When ordering a product that is interchangeable with a NCY2B6, add the suffix, X1468 to the end of the NCY3B6 model number (Refer to page 12).

Be aware that the output circuit is not active immediately after the power is connected. 3.1-12 PSE100 Dimensions A: Panel mount 56 l50 Gasket (Accessory) 7.4 l48 PRESSURE SWITCH 10 8 l 45 A Panel mount adaptor (Accessory) 55 11.4 Cover for display (Optional) 62 4 X 7.5 (= 30) 6.5 7.5 10-M3 2-M3 X 8L 30 View A Cutout dimensions for panel mount 65 or more 45 +0.6 0 +0.6 0 45 +0.6 0 N pieces

3 x 7.2 (= 21.6) 8-M3 OUT2 NC Sensor 36 +0.5 0 8 Load 6.4 4 OUT1 Black 7 3 Load 1 2 3 4 Brown + 6 2 +0.5 0 Blue 19.4 5 1 12 to 24 VDC Series PF2D5 5 6 7 8 PF2D301-A(-M) Do not connect the white wire of the sensor to c of the display unit.

Flow Rate and Sonic conductance AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 0.28 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 8 1/4" 5/16" 460 1.3 6 6 2 10, 12 8 6 10 Flow Direction Symbol on Body Tube O.D.

Applicable model Indicated pressure range Unit display Scale range 100 to 0 kPa kPa 270 180 10 width across flats Pressure Gauge GZ33 Assembly P601010-12 GZ33-K-01 q w e Included Parts No. 1 2 3 30 Description Pressure gauge Gauge nut O-ring R 1/8 3 breathing port 9 1 to 3 are assembled before shipment. (17) 13 GZ43-K-01 Pressure Gauge GZ43 Assembly P601020-12 l12 q w e Included Parts No.

Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.

A functional earth cable must be connected to the M3 terminal. If this product is connected using power cables that are more than 30m long or go outside of a building then external protection devices should be added to protect against electrical surge damage.

B AC (83) C A B -16No.PF-OMO0004CN-E 0.450.55 Nm ,, (ZS-33-M) (ZS-33-MS) M34 (84) M3 M3 -17No.PF-OMO0004CN-E M3(2) 0.350.45 Nm (84) M3 DIN DINDIN DIN0.350.45 Nm () DIN DIN F02(G/14)DIN DIN -18No.PF-OMO0004CN-E IN8cm 2F.S.

Part number Description Remarks ZS-28-A Power and output lead wire and connector Length: 2 m ZS-28-B Bracket Mounting screw (M3 x 5 L) 2 pcs. ZS-28-C Sensor connector 1 pc. ZS-27-C Panel mount adapter Mounting screw (M3 x 8 L) 2 pcs. ZS-27-D Panel mount adapter + Front protective cover Mounting screw (M3 x 8 L) 2 pcs.

Use the attached mounting screw (M3 x 0.5 x 14) for mounting. The mounting screw (M3 x 0.5 x 7) attached to the digital pressure switch assembly will not be required.