SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-31-04-M3"

(mm) Electrical entry P Port size A B C D E F H K L M N Model Grommet: G Conduit: C DIN terminal: D Conduit terminal: T Q R Q R Q R S Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 45 44 43 58 40.5 46.5 99 43 66 83 1/8 VCW21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 46 44 44 58 41.5 46.5 99 44 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 56.5 46 54.5 60 52 48.5 101 54.5 68 99 1/4

Franklin Road Indianapolis, IN 46226 No response to any inquiry shall be interpreted to restrict, expand or modify the warranty described herein. 28 Series KV2 Notes 29 Series KV2 Notes 30 Series KV2 Notes 31 Global Manufacturing, Distribution and Service Network Worldwide Subsidiaries EUROPE AUSTRIA SMC Pneumatik GmbH (Austria) BELGIUM SMC Pneumatics N.V./S.A.

(P.32) (1) [IO] PLC PLC Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG(-) 0E ESTOP 0E JOG(+) 0F ALARM 0F FLGTH 101A CC-Link 101F CC-Link 1B READY 1C1F CC-Link (1) [] PLC RWr PLC RWw RWr bit RWw bit 0 (L) 0 1 (H) 1 (

, 250(2 1/2") 300(3") 400(4") 056(9/16") 075(3/4") 106(1 1/16") 150(1 1/2") 200(2"), 250(2 1/2") 300(3") 400(4") RCSK-015 RCSK-02 RCSK-03 RCSK-04 RCSK-05 RCSK-08 RCSK-10 RCDK-015 RCDK-02 RCDK-03 RCDK-04 RCDK-05 RCDK-08 RCDK-10 Rod Clevis Pin Applicable bore size Including Kit no.

M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3

"), 250 (2-1/2") RCSK-015 RCSK-02 RCSK-03 RCSK-04 RCSK-05 RCDK-015 RCDK-02 RCDK-03 RCDK-04 RCDK-05 Rod Clevis Pin Applicable bore size Including Kit no.

Assembly is required. 7 Technical Data Pressure dew point Condensed water calculation Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure

Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VK VZ1120--M5 (Piping: 4 x 1 m) VZ VF AS1301F-M5-04/AN120M5 AS1301F-M5-04/AN120-M5 Speed controller/Silencer VFR

.) + Release valve (N.C.) 04 2xRc1/2 K2 Supply valve (N.C.) 8() F06 G3/4*1 B1 Supply valve (N.O.) + Release valve (N.C.) F04 2xG1/2*1 B2 Supply valve (N.O.) N06 NPT3/4 5/16(inch) 6) Rated voltage N04 2xNPT1/2 5 DC24V *1: The thread shape complies with the G thread standard (JIS B 0202).

Assembly is required. 7 Technical Data Pressure dew point Condensed water calculation Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure

A dryer with heavy duty auto-drain (ADH4000-04) is installed instead of the float type auto-drain (AD44). Option symbol R With circuit breaker A circuit breaker is attached to the side of the air dryer.

Model AU ALU ALHU F R Port size 3 5 32 04 M3, M5 M3 M5 Barb fitting M3 x 0.5 M5 x 0.8 3.2 4 Barb elbow Barb One-touch Plug-in reducer 3.2, 4 For details on applicable tubing O.D. and port size combinations for each model, refer to the charts on the Dimensions page. 191 B M Series Dimensions Barb Fitting: M-3AU-2, M-5AU-2 Applicable tubing O.D. / I.D.

Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.

Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.

JAS Series How to Order Port size M3 M3 x 0.5 M5 M5 x 0.8 U10 10-32UNF JAS L E A 04 M5 JAS L E A S 04 01 Seal method Type L Elbow Nil Without sealant S With sealant Control type1 Port size E Meter-out S Meter-in 01 1/8 1 Meter-out and meter-in types can be visually identified by the color of the knob.

M3 female -M3 male M-3UL For soft nylon tube. Barb elbow P. 92 3.18/2.18 Body rotates at 360 around the stud axis. Nipple M-5ALU-3 Fitting to workpiece and fitting to fitting connection. P. 90 For polyurethane tube. 3.18/2 M3 Universal tee M5 male -M5 male M-5N Body rotates at 360 around the stud axis. M3 female -M3 female -M3 male For soft nylon and polyurethane tube.

VS3145-04 VS3145-06 VFN 1 4, 3 8, 1 2 64 64 65 70 1 136 35 9 64 54 19 32 50 50 118 96 120 60 7 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 133 96 140 66 9 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 64 50.8 163 196 68 60.5 1 2, 3 4 4-16-7

32 50 50 7 60 120 96 118 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 9 66 140 96 133 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 163 64 50.8 196 68 60.5 1 2, 3 4 4-16-7

Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 16-14-21