SMC Corporation of America
Elite Part Number Search
Search Results "LVM15R3HY-5C-10-Q"

Example) AW30K-03BE-1N-B B AW 30 03 BE K q w e r t y q Body size 20 30 40 60 Symbol Description w With backflow function Nil Without backflow function K Note 1) With backflow function + e Pipe thread type Nil Rc N Note 2) NPT F Note 3) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 r Port size 10 1 + a Mounting Nil Without mounting option B Note 5) With bracket H With set nut (for panel mount

DDM Battery powered: 2A dry cell battery x 2, continuous use for 15 hours or more. 1675 Cylinder Speed Checker IN574-95/-73 RoHS How to Order Sensor head + Display part IN574-95 Display part Sensor head IN574-73 Sensor head Speed Measurement Type IN574-95 Model q Sensor head (q Sensor head + w Display part) w Display part w Display part q Sensor head Application example Time Required for

Description Material 1 Body Aluminum die-casted 2 (B) 4 (A) 2 Spool assembly Aluminum/FKM e 3 Plug (For the -X1) Steel 1 High Speed Pilot Operated Solenoid Valve DXT1215 Series How to Order Valves DXT1215 T 5 Wm U 01 N X1 w y e r t u q q Coil type w Rated voltage e Electrical entry M8 connector1 T With power-saving circuit 5 24 VDC Wm WO With straight connector cable Without connector cable

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, VALVE, LVM CHEMICAL VALVE, 2 PORT, 2A, LVM BODY PORT, NO SIZE RATING, 0.11671 lb

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.045 lb

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.05300 lb

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 53.00000 lb

Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.05300 lb

Q=226S P(P2+0.1013) Sonic flow : P1+0.10131.89(P2+0.1013) Q=113S(P1+0.1013) Q : Flow rate [ /min(ANR)] S : Effective area (mm2) P : Pressure differential (P1-P2) [MPa] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] When the air temperature is different, multiply the flow rate calculated with the above formula by the following coefficient for compensation. -20 1.08 -10 0 10 30

(0.45 MPa) 45 (0.45 MPa) 10 (0.45 MPa) 125 (0.45 MPa) 10 (0.45 MPa) Maximum ow rate [L/min] 120 16 130 16 180 16 Maximum pump head [m] 50 49 55 49 68 49 Settable pressure range5 [MPa] 0.10 to 0.50 0.10 to 0.49 0.10 to 0.55 0.10 to 0.49 0.10 to 0.68 0.10 to 0.49 Minimum operating ow rate6 [L/min] 20 2 25 2 40 2 Tank capacity [L] 42 7 42 7 60 7 Bypass circuit (With valve) Installed Electric

Note 10) The anchor bolt xing brackets (including 4 M10 bolts) are used for xing to wooden skids when packaging the thermo-chiller. No anchor bolt is included. 138 A

[10] Be sure to read this before handling the products.

When the inlet pressure (P1) is shut off and released, the check valve w opens and the pressure in the diaphragm chamber q is released into the inlet side (Figure 2). This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e lifts the diaphragm.

2 q Magnet 9 Piston 10 POM Seal piston 11 NBR 1/8 15 23 Scale plate 12 PC Wiring Warning Mounting Warning Pressure Source Warning 1. 1. 1. Connect load before connecting with power source. The switch will break instantly if no load is connected. Make the wiring length as short as possible.

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Specifications )haracterislica vEA130 VEA250 iupply Power 1 10/220V + 10% (50/60H2) DC24V +2V tower Consumption sOVA 29W )utput Current Range 0-0.75A 0-1A mpedance ol E/P rroportional Valve 26-36s2 (0.75AF.S.) 13-18.5() (1A F-S.)

(See q.) If current decreases at this point, the flow rate may not change by 135 mA due to hysteresis. (See w.) The flow rate at increasing current and decreasing current are not the same due to hysteresis. (q 85 l/min., e 93 l/min.) Condition 2. P1 = 0.7 MPa, P2 = 0.2 MPa Refer to curve B when P is 0.5 MPa.