SMC Corporation of America
Elite Part Number Search
Search Results "LEYG25LDEC-30C-R3C5173"

(Refer to the instruction manual for details on the cleaning.) 42 47 49.5 40 39.5 43 44.5 34.5 35.5 36 38 40 41.5 10 12000 14000 HAW75 15000 18000 20 45 48.5 52 45 39 40 42.5 41 43 45.5 34.5 35.5 36 HAW110 Conditions: Air pressure 0.7 MPa, Cooling water temperature 30C. Inlet air temperature 50C is saturated air.

(Refer to the instruction manual for details on the cleaning.) 10 12000 14000 40 HAW75 15000 18000 20 45 HAW110 Conditions: Air pressure 0.7 MPa, Cooling water temperature 30C Inlet air temperature 50C is saturated air.

Given an ambient temperature at 86F (30C) and a relative humidity 60%. 1. Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102 psi (0.7 MPa). 3.

Standard dew point 22F (30C) Adsorbent set for standard dew point 4.7 4.7 6.7 6.7 ID-200S ID-300S ID-400S ID-600S Dimensions 240 240 320 320 9.4 9.4 12.6 12.6 520 615 850 961 Heatless Air Dryer Series ID AM150-N02 AM250-N04 AM250-N04 AM350-N06 Mist separator Model Compact and light weight without heater and electric control board 20.5 24.2 33.5 37.8 110V Single-Phase 60hz Bracket 6604113

This system Your system Communication data TEMP PV 30C TEMP PV TEMP PV 30C TEMP SP 30C External communication 30C Discharge temp: OFFSET 1C 31C dissipation: Heat 1C Circulating fluid temp. in your system: 30C Figure 8-7 When MODE3 is selected HRW Series 8.4 Offset Function 8-11 HRX-OM-K003 Chapter 8 Appendix 8.5 BAND/READY function Sets BAND to TEMP SP value, and notifies TEMP PV value reaches

Cool from 30C (303 K) to 20C (293 K). : Clear water Density : 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath Refer to the information shown below for the typical physical property values by circulating fluid.

Cool from 30C (303 K) to 20C (293 K). Circulating fluid : Tap water Density : 1 x 103 kg/m3 Specific heat C : 4.2 x 103 J/(kgK) Refer to the information shown below for the typical physical property values by circulating fluid. Water bath Q = T x V x x C h x 60 x 1000 10 x 2 x 1 x 103 x 4.2 x 103 20C V = 15 x 60 x 1000 After 15 min, = 93.3 W cool 30C down to 20C.

Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

Cooled substance total volume V Cooling time h Cooling temperature difference T Circulating fluid : 20 L : 15 min : 5C (5 K) : Clear water Density : 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) T xV x x C h x 60 x 1000 Q = Cools 20 L of clear water from 30C to 25C in 15 minutes. 5 x 20 x 1 x 10 3 x 4.2 x 10 3 V = 15 x 60 x 1000 AL SI OUT = 467W PURGE OUT PURGE IN CHEMICAL POWER IN WATER

Given an ambient temperature of 30C and a relative humidity of 60%. Trace the arrow mark, from point A of ambient temperature 30C to obtain the intersection B on the curved line for the relative humidity of 60%. Trace the arrow mark, from the intersection B to obtain the intersection D on the curved line for the 0.7 MPa pressure characterisitics.

Pressure Gauge + Lubricator Regulator with Built-in Pressure Gauge with Back Flow Mechanism ACG20A/30A/40A P .7 ARG20K/30K/40K P .24 Air Filter + Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge ACG20B/30B/40B P .9 Filter Regulator with Built-in Pressure Gauge Air Filter + Mist Separator + Regulator with Built-in Pressure Gauge AWG20/30/40 P .31 ACG20C/30C

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 5 0 Intake air temperature C (Atmospheric pressure) Air temperature (Pressure dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized

1 series 10C 20C 30C Standard model (Normal operation) Set dew point Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 10 to 30C. 2. Normal operation (ECO LED is OFF): Dew point is fixed to 10C. Description No.

Given an ambient temperature of 30C and a relative humidity of 60%. Trace the arrow mark, from point A of ambient temperature 30C to obtain the intersection B on the curved line for the relative humidity of 60%. Trace the arrow mark, from the intersection B to obtain the intersection D on the curved line for the 0.7 MPa pressure characterisitics.

Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C

Water Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Conventional units Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.00 4.2 x 103 1.00 1 x 103 10C 1.00 4.19 x 103 1.00 1 x 103 15C 1.00 4.19 x 103 1.00 1 x 103 20C 1.00 4.18 x 103 1.00 1 x 103 25C 1.00 4.18 x 103 1.00 1 x 103 30C 1.00 4.18 x 103 1.00 1 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 40C

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

Cool from 30C (303 K) to 20C (293 K). : Tap water Density g: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath * Refer to the information shown below for the typical physical property values by circulating fluid.

Once the discharge temperature of the circulating fluid becomes 31C, 1C-thermal dissipation is assured to allow the circulating fluid in your system to be 30C. TEMP SP value is obtained for your system. TEMP PV and communication data also express 30C (circulating fluid discharge temp. value OFFSET value) that agrees with the temperature of the circulating fluid in your system.