Specifications Model XLDV-25 XLDV-40 XLDV-50 XLDV-63 XLDV-80 XLDV-100 XLDV-160 Flange (valve) size 25 40 50 63 80 100 160 Actuating type Normally closed Fluid Vacuum of inert gas Operating temperature oC 5 to 60 Operating pressure Pa Atmospheric pressure to 1 x 10-6 Main pumping 14 45 80 160 200 300 800 Conductance l/s Note 1 Initial pumping 0.53 28 2.511 48 418 6.531.5 6.531.5 Internal 1.3
The available bore sizes are 125, 160, 200, 250, 320 and 400. 2-3. No signal operation With No signal operation (Menu Tree No.1-3-5-3-3), the piston rod operation can be set when the input signal of 3.5mA or less is input. The available operation is Retracted end. Calibration position and Stay. 2-4.
Scraper (piston rod) 1 million full strokes or 200 km. Ball screw shaft Approximately 6 months Grease pack order number (Arrange separately) GR-S-010 (10g), GR-S-020 (20g), GR-S-400 (400g) Please contact us for the Maintenance Manual. 3. It is recommended that apply the appropriate covering to the electric actuator in the environment of splashing the liquid other than water.
100 400 200 400 200 Actuator specifications Pushing speed[mm/s] 20 to 30 10 to 30 5 to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion[mm] *4 0.1 or less Screw lead[mm] 10 5 2.5 12 6 16 8 Impact/Vibration resistance[m/s2] *5 50/20 Actuation type Ball screw (In-line) Ball screw + Belt (parallel) Guide type Linear
Unit 3 Inrush current filter 0.1 ms Sets the time to ignore the input signal change. 20 ms 1.0 ms Selects the time for filtering. 1.0 ms Unit 4 Input filtering time 10 ms 1.0ms Sets the time to hold the input signal. 200 ms 5 Input extension time 15 ms Selects the time to hold the input signal. 15 ms Unit 100 ms Enable Generates an error.
Disable Does not ignore excess current Enable Ignores excess current. 2 Inrush current filter (Inrush) 0.1 ms 1.0 ms 10 ms 3 Input filtering time (Filter_T) Sets the time to ignore the input signal change per unit 20 ms Selects the time for filtering. 1.0 ms 1.0 ms 15 ms 100 ms 4 Input extension time (SigExt_T) Sets the time to hold the input signal per unit. 200 ms Selects the time to
> Network information including the GW unit MAC address and communication speed are displayed. 38 No.EX-OMS0014-A Specification Specifications Basic Specifications Item Specifications Power supply voltage range Power supply for input and control: 24 VDC 10% Power supply for solenoid valve: 24 VDC +10%/-5% Power supply for input and control: 6.2 A (GW unit internal current consumption: 200
Selects the time to hold the input signal. 15 ms 200 ms Memorizes the number of times the input device is ON. Generates error per channel when the operation count exceeds the set value. 3 Enable Generates an error.
Solenoid Valve for 200/220 VAC Specification Warning AC specification solenoid valves with grommet have a built-in rectifier circuit in the pilot section to operate the DC coil. With 200/220 VAC specification pilot valves, this built-in rectifier generates heat when energized.
Specifications Table. 9-1 EX245-EA2-1 specifications Item Description General Dimensions (W x L x H) in mm 28.6 x 120 x 61.5 Weight 200 g or less Housing material Nylon Table. 9-2 EX245-EA2-2 specifications Item Description General Dimensions (W x L x H) in mm 14 x 120 x 61.5 Weight 100 g or less Housing material Nylon NOTE EX245-EA2-2 can be used to have a special bracket which must be
LAT3LAT3MLAT3F600 350 700 Load weight1000g Load weight1000g Load weight1000g 300 600 Positioning time [ms] Positioning time [ms] Positioning time [ms] [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
Applicable cable O.D. 6 to 8 Caution Caution DIN terminal block DIN terminal Terminal no. 1 2 Lead Wire Color (Grommet) Caution Voltage Color 100 VAC Blue 200 VAC Red DC Red (+), Black () Others Gray Light/Surge Voltage Suppressor AC DC Caution Indicator light assembly (DIN terminal: Yes, Grommet: No) Description Part no.
AD27-A I.D. f2.5 (f3/32") at min., Length 5m (200") at max. AD37, 47(N)-A I.D. f4 (f3/16") at min., Length 5m (200") at max. AD38, 48(N)-A: I.D. f6.5 (f1/4") at min., Length 5m (200") at max. 5 Air Source WARNING Use clean air. Compressed air containing chemicals, organic solvent, synthetic oil or corrosive gas may lead to cause breakage of parts or malfunction.
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
type) Displacement m Displacement m 200 200 150 150 130 120 50 50 MSZA30A (High precision type) MSZA50A(High precision type) D70 60 50 40 30 20 10 0 120 100 80 60 40 20 0 Load N Load N 291 Rotary Table Air Consumption Air consumption is the volume of air which is expended by the rotary tables reciprocal operation inside the actuator and in the piping between the actuator and the switching
IC circuit 5 V A76H A96V A96 Yes A72 A73 A80 A72H A73H A80H 200 V Solid state switch Reed switch Grommet 100 V 12 V IC circuit A90V A93V A90 A93 5 V, 12 V 12 V 12 V No Relay, PLC 2-wire 24 V Yes Connector A73C A80C A79W F7NV F7PV F7BV J79C F7NWV IC circuit 5 V, 12 V No Grommet Diagnostic indication (2-color display) Yes 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F9NV F9PV F9BV M9N M9P M9B 5 V,
ASS ASR ASF Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.