Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: Standard, Semi-Standard 2: Standard, Made to Order: X2141 (w/Element Service Indicator)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: Standard, Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: C (N.C. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40A, Thread: F (G), Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Stations: 3 Stations, Port Size: 04 (Rc1/2), Electrical Entry Direction: D (Plug-in F Kit D Side), Cable Length: 1 (1.5m Cable 25 Pin), Option: SU (Built-in Silencer, Direct Exhaust from U Side)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Piping: 20 (Body Ported), Stations: 4 Stations, A, B Port: 00T (NPTF), Bracket: F (Bracket)
Piping: 20 (Body Ported), Stations: 4 Stations, A, B Port: 00N (NPT), Bracket: F (Bracket)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)