GND 10 [ms] or longer Disconnected AUTO-SHIFT terminal GND 10 [ms] or longer Disconnected 16-13-10 18 Technical Information Channel selection function 13 How to Activate the Auto Shift Function Channel Selection Function is explained with an example when adsorbing workpiece. The pressure on the nozzle varies according to the nozzle diameter.
DOWN button Pneumatic circuit SET button UP button Lead wire length 600 50 (3000) 10 58 PV 18 10.2 8 6.5 10.25 10 22.6 5.75 Vacuum pad connection port Vacuum supply port 2-3.3 Mounting hole 0X: M5 x 0.8 0XY: M6 x 1.0 0X: M5 x 0.8 0XY: M6 x 1.0 16-4-8
L H Number of rotations 0 5 10 15 18 23 Applicable setting range 27 to 80 kPa Non-adjustable range Max. number of rotations are 18. Caution 1. How to Set Vacuum Pressure The pressure setting trimmer is used to set the on-pressure. Clockwise rotation increases the on-pressure setting. Pressure adjusting screw Switch assembly Indicator light Pressure Source Warning 1.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN A port LVC 2-G LVA LVH SMC LVD SMC (J) C LVQ LQ E LVN TI/ TIL PA F K B port E PAX PB A B C D E F G H J K S LVN20 LVN30 LVN40 Model 48 60 72 2.4 7.5 8.0 18 24 30 20 26 33 14 25 25 4 5 6 6 9 11 34.5 43 52 88 110 124 12 18 22 24 30 36 17-5-135
AC, DC C.O. 7.5 55 6 45 50 42 18 60 37 12 AC Cv converted Av x 10 6 (m 2 ) VX32 AC (Full wave rectification) 50/60 10 8.5 60 1 3 5 0.08 1.5 1.0 0.6 220 1.9 VX311 -00 DC 8.5 60 11 60 9.5 50 1 3 5 0.16 0.5 0.3 220 3.8 VX312 -00 50 55 22 60 47 18 AC 0.6 370 VX3225-00 2.2 0.19 4.6 VX33 1.0 530 VX3325-00 AC (Full wave rectification) 50/60 14 11.5 60 1 3 5 0.24 DC 11.5 60 0.3 0.2 5.8 220 1.0
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Spanner spout, hexagon Model Port size P Rc A B C D E F With bracket Port size G H I J 1 8 1 4 1 4 3 8 10 VXA21 VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 11.5 Dimensions (Orifice Size: 8 mm, 10 mm) VXA225/VXA226 Thread fixed: (VXA2262
Frequency (Hz) 50 60(53) 18 60 51(44) 12 Model Power source VX3 7.5 6 8 11 9.5 11.5 AC VXZ22 VXA DC 50 80 21 60 67 17 AC VXZ23 VN DC LVC JIS Symbol LVA OUT LVH IN LVD N.O.
ZF ZFA100 Port size Symbol Model A B 18 20 28 ZFA200 1 8 1 4 ZP Manifold ZCU AMJ Misc.
Flow Rate: .65 CFM / 18 LPM , .65 CFM / 18 LPM, Max Pressure: 15 PSIG / 1 bar , 15 PSIG / 1 bar, Max Vacuum: 23 in HgV / -780 mbar , 23 in HgV / -780 mbar, Voltage (DC): 12, Item Dimensions: Length: 6.17 in / 157 mm Width: 3.35 in / 85 mm Height: 5.12 in / 130 mm , Length: 6.17 in / 157 mm, Width: 3.35 in / 85 mm, Height: 5.12 in / 130 mm, Net
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 18 LPM , 18 LPM, Max Pressure: 7.2 PSIG / 496 mbar , 7.2 PSIG / 496 mbar, Max Vacuum: 25.1 in HgV / -850 mbar , 25.1 in HgV / -850 mbar, Voltage (DC): 24, DC Motor Type: BLDC, Item Dimensions: Length: 4.84 in / 123 mm Width: 1.85 in / 47 mm Height: 3.07 in / 78 mm , Length: 4.84 in
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .8 LPM , .8 LPM, Max Pressure: 10.7 PSIG / 738 mbar , 10.7 PSIG / 738 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 4.5, DC Motor Type: Standard, Net Weight: .09 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .8 LPM , .8 LPM, Max Pressure: 11.6 PSIG / 800 mbar , 11.6 PSIG / 800 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 6, DC Motor Type: Standard, Net Weight: .09 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Enclosure: W (IP67), SI Unit: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 16 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N3 (5/32" One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: 18 (for 18 Stations; Longer Rail than Total Length of Specified Valve Stations
Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 16 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N3 (5/32" One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: 18 (for 18 Stations; Longer Rail than Total Length of Specified Valve Stations
18 station VQ2000 manifold
Regulator Mounting: A (Direct Mount), IN/OUT Fitting Type: 18 [IN/ø4 (Elbow) - OUT/ø4 (Elbow)], Accessory: A (w/Pressure Gauge), Options: 2 (Non-Relieving), Unit Representation: Z (Display Unit for Product Name Plate and Pressure Gauge: PSI)
Piping: 20 (Body Ported), Stations: 18 Stations
Pressure Range: 0~0.97MPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: NPN Open Collector 1 Output, w/Analog Output, 3 Rotation setting, Wiring Specification: -