/ mm mm mm c.p.m. mm(L1-L2) (L1) (L2) g MHL2-10D 60 20 56 76 280 MHL2-10D1 40 78 118 345 10 40 MHL2-10D2 60 96 156 425 MHL2-16D 60 30 68 98 585 MHL2-16D1 60 110 170 795 16 40 MHL2-16D2 80 130 210 935 MHL2-20D 60 40 82 122 1,025 MHL2-20D1 80 142 222 1,495 20 40 MHL2-20D2 100 162 262 1,690 MHL2-25D 60 50 100 150 1,690 MHL2-25D1 100 182 282 2,560 25 40 MHL2-25D2 120 200 320 2,775 MHL2-32D

This matches the controller. (1) LEG32MDGB-30 -4- 1.2 Specification Model LEG25 LEG32 LEG40 Horizonal (30,50 stroke, L=50 or less) Work load 20 45 60 kg*1 Vertical 24 27 27 Max.weight of transferred object[kg] *2 75 100 150 Pushing forceN*3*4*5 126 to 238 156 to 370 266 to 553 Actuator specifications Speedmm/s*5 18 to 250 24 to 200 24 to 150 Max.acceleration/decelerationmm/s2 5,000 Pushing

The range of current (0 to 500mA) can be adjusted to 0V of the command signal. (5mA or less when shipped) GAINThis function changes the ratio of current (tilt) to the command signal Current 500mA Command signal 5V MIN 1000mA 5V MAX Adjustable within a 100-200 range (200 when shipped) = mA V mA V 12 VEP-OMM0002-C VEP / VEF / VEA / VER Series Specific Product Precautions 7 Be sure to read

Caution Apparent power Holding18VA50Hz Coil rated voltage (V) AC50/60Hz 100, 110, 200, 220 DC 12, 24 2. Vacuum type [VT/O 315V] If the solenoid valve is mounted on a metal surface, it can breathe through the breathing hole. However, if the valve is to be mounted on a surface made of rubber, it could deform and block the breathing hole.

Reference data Reference Data 6.1 Specifications Item Specification IDH4-10 IDH4-20 IDHA4-23 IDH6-10 IDH6-20 IDHA6-23 Fluid Compressed air Amount of air processed 100 to 500L/min (ANR) 200 to 800L/min (ANR) Inlet air temperature 5 to 40oC Inlet air pressure 0.3 to 1.0MPa Note 1) 2) Operating Ambient temperature 15 to 35oC (Relative humidity 85% or less) range Outlet air temperature adjustment

current. 3 [Inruch Current Filter] 0.1 ms Input filtering time [Filter_T] Sets the time to ignore the input signal change per unit. 20 ms 1.0 ms Selects the time for filtering. 1.0 ms 4 10 ms [Input Filtering Time] 1.0ms Input extension time [SigExt_T] Sets the time to hold the input signal per unit. 15 ms Selects the time to hold the input signal. 15 ms 5 100 ms [Input Extention Time] 200

specification> Cable: Shielded twisted pair cable (Type-A cable) Impedance 135 to 165 (3 to 20 MHz) Capacitance between conductors Less than 30 pF/m Conductor resistance 110 /km or less Wire diameter 0.64 mm or more Conductor area 0.34 mm2 or more Transmission speed and maximum cable length Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 12000 Cable length (m) 1200 1000 400 200

Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 : Cable Type A specification Item Specification Impedance 135 to 165 Capacity 30 pF/m or less Loop resistance 110 /km Wire diameter 0.64 mm or more Core cross-section 0.34 mm2 or more Lower-level bus Item Specification Number of branches for input/output 4 branches (16 points

The proof pressure is double the operating pressure range. -27No.LV50***-OMQ0004-F Analogue output Flow rate/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow rate[L/min] B Model Minimum Maximum A LFE1 0.5 20 Flow rate 0 Minimum rated flow Maximum rated flow LFE2 2.5 100 LFE3 5 200 Out of range -28No.LV50***-OMQ0004-F Dimensions Note)

LEMB / LEMC LEMH / LEMHT Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] 0 48 250 48 250 1 75 500 75 500 2 100 1000 100 1000 3 150 1500 150 1500 4 200 2000 200 2000 5 250 2500 300 2500 6 300 3000 400 3000 7 350 4000 500 4000 8 400 5000 600 5000 9 450 6000 800 6000 10 500 7500 1000 7500 11 600 10 1200 10 12 700 12500 1400 12500 13 800 15000 1600 15000 14 900 17500 1800

Outer dimensions and descriptions of each part 4Outer dimensions and descriptions of each part 1) Outer dimensions Model HAA15-10 HAA22-14 PORT SIZE 1B union 11/2B union A 460 588 B 394 484 C 33 52 D 70 70 E 59 60 F 485 580 G 428 505 H 320 333 J 150 150 K 150 150 L 320 400 M 70 94 N 58 65 P 200 200 Q 480 610 R 220 220 S 225 238 HAA Series 6 4 1) Outer dimensions ATX-OM-F004E Air-Cooled Aftercooler

Solenoid Valve for 200, 220 VAC Specifications Manual Override Operation Solenoid valves with grommet and L/M type plug connector AC specifications have a built-in rectifier circuit in the pilot section to operate the DC coil. With 200, 220 VAC specification pilot valves, this built-in rectifier generates heat when energized.

The cylinder section does not have a water resistant enclosure. 3-3 Allowable Kinetic Energy 3-3-1 Allowable Kinetic Energy (J) Bore size(mm) 12 20 32 40 50 63 Allowable Kinetic EnergyE 0.022 0.055 0.15 0.26 0.46 0.77 3-3-2 Mass of Cylinder Movable Parts (g) Cylinder stroke (mm) Bore size(mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 28 33 38 43 48 53 20 70 84 98 112 126 140 154 168

. + = 4 . 1 = a V V 2 V m M E k 2 Ek: Kinetic energy (J) M : Mass of object being transported (kg) m : Mass of moving parts of cylinder (kg) V: Maximum speed (m/s) Va: Average speed (m/s) Mass of moving parts of cylinder (kg) Bore size Standard stroke (mm) (mm) model 20 25 30 40 50 75 100 125 150 175 200 250 300 350 MLGPM20 0.40 0.42 0.45 0.47 0.59 0.65 0.71 0.77 0.83 0.89 1.08 1.20 1.31

Option Rated voltage Voltage symbol Part no. 100 VAC 100V VK300-82-2-01 110 VAC 110V VK300-82-2-03 200 VAC 200V VK300-82-2-02 Note) When requiring a gauge different than that mentioned above, specify the model number. 220 VAC 220V VK300-82-2-04 Option is packed with it.

XMA-16 XMA-25 XMA-40 XMA-50 XMA-63 XMA-80 XYA-25 XYA-40 XYA-50 XYA-63 XYA-80 Flange (valve) size 16,CF034 25 40,CF070 50 63,CF114 80 Actuating type Normally closed (Pressurize to open , spring seal) Fluid Vacuum of inert gas Operating temperature oC 5 to 60 (High temperature type:5 to 150) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 2 5 14 45 80 160 200

.: GR-S-010 (10 g) 72 Compact Cylinder/Large Bore Size: Double Acting, Single Rod Series CQ2 Replacement Procedure is 125, 140, 160 180, 200 P.290 Construction Standard Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !2 !3 !

Contents Bore size (mm) CQ2WB125-PS CQ2WB140-PS CQ2WB160-PS CQ2WB180-PS CQ2WB200-PS 125 140 160 180 200 CQ2WB125-PS CQ2WB140-PS CQ2WB160-PS CQ2WB180-PS CQ2WB200-PS !1 !2 !3 Piston seal Rod seal NBR Set of left nos. !1, !2, !3. Tube gasket Seal kit includes !1, !2, !3. Order the seal kit, based on each bore size. Since the seal kit does not include a grease pack, order it separately.

Specifications Bore size(mm) Item 40/63/100 1.5MPa 1.0MPa 0.1MPa 10 to 60C (With no freezing) Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature Piston speed +1.0 0 20 to 200 mm/s mm Stroke length tolerance Grease Particle generation grade Fluorine grease Grade 2 (Refer to front matter pages 13 to 22 for details.) 94 Guide table10-MGF Auto switch

Piston speed (3) 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage MQQ M 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Supply pressure 0.3 MPa 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa RHC Note 1) Use clean, dry air with no freezing.