0.05 0.07 0.05 0.07 U W M5 x 0.8 U W 597
EU1 EX600 2 End Plate (U side) Mounting method End plate Symbol Description Nil Without DIN rail mounting bracket 2 With DIN rail mounting bracket End plate mounting position: U side Specications When the end plate (D side) is used, the symbol for the mounting method must be the same as the U side. Symbol Specications 1 Waterproof cover 8
One-touch fitting N3 Inch 5/32" One-touch fitting N7 1/4" One-touch fitting BM Bellows type with groove UM Flat type with groove ZL ZH Pad material N NBR (Black) S Silicone rubber (White) U Urethane rubber (Brown) F FKM (Black) Mounting ZH Ejector/ Nozzle nominal size [mm] Symbol Type Thread Size A Metric size ZH -X267 Male thread M8 B M10 C Female thread M8 D M10 E Inch size 07 Nozzle:
4 x Sa Thread depth Sb G M N A D F Vacuum flow Dust bag When dust bag is mounted E T Suction air Suction air Discharge air B C C U Hose band V Note 1) (mm) A 158 B 70 C 50 D 20 E F 24.5 G 60.5 H 5 I 70 J 60 K 5.5 L 72 M 37 N 2 O 30 P Rc1/4 Q R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185 ZH40--X185 28.5 146.5 M4 x 0.7 10 203 90 64 25 27.2 33.5 196.8 74.5 6 90 78 6.5 92 47 2.3 42 Rc3/8 76 500
Options 14.1 Actuator cable [5m or shorter] (1) (2) LE-CPSignal name Terminal number Cable color Terminal number A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 (3) 5 5m Shield Cable color Terminal number Vcc B-4 Brown 12 Actuator cable type GND A-4 Black 13 A B-5 Red 7 Nil Robotic type cable A A-5 Black 6 B B-6
Power Supply Cable with M12 Connector (B-coded) SPEEDCON Straight connector type Angle connector type Socket connector pin arrangement B-coded (Reverse key) -114No.EX-OMU0028-D 8.
Power Supply Cable with M12 Connector (B-coded) SPEEDCON Straight connector type Angle connector type Socket connector pin arrangement B-coded (Reverse key) -125No.EX-OMW0006-D 8.
1 IO-Link master Number of ports and connector Symbol Number of ports Connector Port specifications B 4 ports M12 connector Symbol Content A Port Class A B Port Class B Summary of Product parts EX600-L#B1 No.
Refer to pages 1745 and 1746 for details. 25 46.5 34.5 30 55 43 10 31 19 31 19 15 36.5 24.5 5 25.5 26.5 13.5 14.5 10 30.5 31.5 18.5 19.5 A B C D A B A B A B A B MXP8 DMXP6 MXP10 -X MXP12 Individual -X MXP16 Note) Adjust the auto switch after confirming the operating conditions in the actual setting. 209 Series MXP Specific Product Precautions 1 Be sure to read before handling.
Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.
Install the separately connected controller and high voltage power B : M4 thread B : M4 thread supply module by at location B using M4 screw (x 6). Refer to 6. Dimensions for details. B : M4 thread B : M4 thread .Adding a high voltage power supply module a. High voltage power supply module to be added should be Connected by D-sub connector at location C.
Formula for Obtaining the Set Value A B ZSP P_1 or P_3 P_2(H_1) or P_4(H_2) PSE200 PSE300 P_1(P_3)=A-(A-B)/4 P_2(P_4)=B+(A-B)/4 Hi Auto-shift input PS H_1(H_2)=(A-B)/2 Lo ISA B Switch output response time at time of auto-shift input A Auto-shift input time C Precision indicator setting PSE PSE200 PSE300 15 ms or less 10 ms or more This function eliminates slight differences in the output
8 Product image For PROFIBUS DP (Plug, B-coded) Socket Plug Plug Socket Number of functional poles M12: 2 pins M12: 3 pins M12: 4 pins Key type B-coded (Reverse key) 3 4 4 3 5 1: VP 4: B Line 5 1: 2: A Line (Green) 3: 4: B Line (Red) 5: 390 1 2 2 1 Pin assignment 220 2: A Line 3: DGND Plug, B-coded Plug, B-coded (Viewed from the plug/socket side) 390 Fixed cable length 5 m Cable O.D
V W Y Z B B B B B B B AW20K-D 30 34 43.9 5.4 15.4 55 2.3 29.7 28.5 14 6 104.9 91.4 87.4 93.9 AW30K-D 41 40 46 6.5 8 53 2.3 31.3 38.5 19 7 157 123.9 122.2 117.8 122.3 137.8 142.3 AW40K-D 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 186.9 155.6 153.9 149.5 154 169.5 174 AW40K-06-D 50 54 55.5 8.5 10.5 70 2.3 35.5 42.5 21 7 188.9 157.6 155.9 151.5 156 171.5 176 AW60K-D 70 75 66 11 22 113 3.2 273.9
T.T. 60 Push button (Mushroom) VM220-02-30R/B/G/Y VM230-02-30R/B/G/Y JIS Symbol 2 port Panel mounting hole 3 port EXH port (3 port only) 0.5 MPa supply 4.9 mm P.T. 52 N F.O.F. 2-5.5 mounting hole 1.6 mm O.T. 6.5 mm T.T. 5-6-23 Series VM200 Series VM200 Push button (Extended) VM220-02-32R/B/G/Y VM230-02-32R/B/G/Y JIS Symbol 2 port 3 port Panel mounting hole EXH port (3 port only) 0.5 MPa
D-A73 D-A80 D-A79W D-F7NTL Bore size A B A B 10 13.5 18 24 A B 7 10.5 15 21 A B 15 18.5 23 29 32 40 9.5 13 17.5 23.5 Note ) Adjust the auto switch after confirming the operating conditions in the actual setting.
B to Nominal filtration accuracy of 5, 10, 25, 50, 100 m can be selected.
C J G5-S Material: Carbon steel Material: Polyurethane (mm) (mm) (mm) CV MM A B M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 B 3.5 4.5 5 6 6.6 C 22 27 32 41 41 h1 25.4 31.2 37 47.3 47.3 C 4 8 8.3 11.3 13.1 h M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 MM B 6 6 6 6 6 C 22 27 32 41 41 Part no. Part no. Part no.
B B B B B B 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7) 7.5 (4.5) 7.5 (4.5) 12 (8) 15 (10.5) 17 (13) 3 (
C J G5-S Material: Carbon steel Material: Polyurethane (mm) (mm) (mm) CV MM A B M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 B 3.5 4.5 5 6 6.6 C 22 27 32 41 41 h1 25.4 31.2 37 47.3 47.3 C 4 8 8.3 11.3 13.1 C 22 27 32 41 41 B 6 6 6 6 6 h M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 MM Part no. Part no. Part no.