This is a legacy product, and replaced byZH20DSA-03-04-04, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, GD, ZH NOZZLE SIZE 2.0, .29828 lb, ModelConnection (One-touch/Screw-in) SUPVACEXHZH20D?12/Rc 3 8?16/Rc 1 2?16/Rc 1 2
The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), VALVE, TIE ROD TYPE W/MFLD BLK, VALVE, SV1000 SOLENOID VALVE, 5-PORT, UI, SV1000 BUILT IN FITTING(
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN, VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
Operation t 0 Single Acting 03 10kgrf/crn'z 04 4kgt'lcm2 06 6kgrf/cnf 11 30psi 12 45 psi 13 150 psi 22 200 kPa 23 300 kPa 24 400kPa 26 600 kPa 41 30 psi & 2 k$l cm2 stainless steel t42 60psi& 4 k$lcm2 stainless steel 43 100 psi & 7 k$lcm2 stainless steel NIL PT Thread PF Parallel Pipe Thread t NPT American National Standard Pipe Thread Accessoriee t NIL Standard Lever Control Lengrth (0.25
Operation t 0 Single Acting 03 10kgrf/crn'z 04 4kgt'lcm2 06 6kgrf/cnf 11 30psi 12 45 psi 13 150 psi 22 200 kPa 23 300 kPa 24 400kPa 26 600 kPa 41 30 psi & 2 k$l cm2 stainless steel t42 60psi& 4 k$lcm2 stainless steel 43 100 psi & 7 k$lcm2 stainless steel NIL PT Thread PF Parallel Pipe Thread t NPT American National Standard Pipe Thread Accessoriee t NIL Standard Lever Control Lengrth (0.25
Power supply voltage (24 VDC or '12 lo 15 VDC) is rcquired Note 3) Selecl either analog oulpul or swtch outpul. Fulher, when swilch output is selecled, select either NPN oulput oI PNP outpul. Nole 4) The.ninimum unrt for lTV205is IPS Note 5) The above characteristics are confined to lhe slatic state. When air is consumed on the outsul side, the prssure may fluctuate.
1 I.{ 50 114 139 13 100 10 t 15 5 9 5.5 v 74 4.5 AMG25O 3/8 '152 13 1 1 3 6 10 '| 69 n '12 4 84 a 5 2 n Ai/lc350 1/2 144 16 145 s s '10 198 m 2 14 7 80 100 g 2.3 ANtG450 314 205 19 147 106 106 JO s 10 14 88 1 1 0 3.2 AMG55O 239 200 10 257 100 s 10 't6 102 130 m 10 4.5 AIVG&5O 1 112 291 c 253 r60 160 10 364 150 .10 20 1 1 s 136 180 4.5 2 48 a 348 220 ?
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Stations: 12 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 03 (Rc3/8), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: NSD (Name Plate, Built-in Silencer, Direct Exhaust from D Side)
.: 12 (ø12), Port Size/Applicable Tubing O.D.: 03 (R3/8, Rc3/8), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plate), Sealant: P (Face Seal)
.: 12 (ø12), Port Size/Applicable Tubing O.D.: 03 (R3/8, Rc3/8), Thread Material/Surface Treatment: N (Brass + Electroless Nickel Plate), Sealant: P (Face Seal)
Body Size: 3 (3/8), Type: 3 (Universal), Control Type: 0 (Meter-out), Indicator Direction: 1(180°), Thread: R, Port Size: 03 (3/8), Applicable Tubing O.D.: 12 (ø12), Seal: S (w/Sealant)
Body Size/Type: 12 (Elbow Size M5), Control Type: 1 (Meter-in), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: U10/32 (10-32UNF), Applicable Tubing O.D: 03 (ø5/32")
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 03 (Side, 3/8), Port Thread: F [G (ISO1179-1 G Threads)], SI Unit: SD60 (Serial Kit w/o SI Unit), End Plate: w/o SI Unit/End Plate, SI Unit COM: +COM, Number of Input Blocks: w/o SI Unit/Input Block, Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block