Flow direction Right Down With element service indicator AMP220 Rc NPT AMP320 AMP420 G 2 Exhaust Cleaner for Clean Rooms Series AMP How to Order AMP 2 0 2 03 Optional specifications Body size None Flow direction RightDown With element service indicator Nil R T 2 3 4 1/4 standard 3/8 standard 1/2 standard Element construction Accessories (optional) Nil None 2 2 stage B With bracket
. 1st printing GT D-036 P-650(DN) Printed in Japan.
Range Back Pressure SMC 22 8.0 -750mmHg~58psi 0~100C 0~30psi (60psi) 136 150 75 Height Width Operator Dia. 1 LVQ60 LQ Seal Locations N u t S e a l L o c k T ubing Support T aper Surface T u b i n g T r ap e zoidal T h re a d s I n s e rt Bushing Nut Lock U.S. Patent #5,996,636 Quadruple Seal Maximum leak protection. Up to 215psi @ 200C.
Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
D-KS This catalog is printed on recycled paper with concern for the global environment.
D-DN This catalog is printed on recycled paper with concern for the global environment.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2012 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing QY printing QY 8150SZ Printed in Japan. D-G
How to Order 2 AW X2622 30 03 Option/Semi-standard: Select one each for a to d. Option/Semi-standard symbol: When more than one specication is required, indicate in alphanumeric order.
Series ACG How to Order ACG 30 A 03 G1 Option Symbol Description Applicable model Body size Nil 1 2 3 6 8 C J N R ACG20 to 40 Port size Symbol (8) 0.02 to 0.2 MPa setting ACG20 to 40 20 30 40 1/8 Metal bowl ACG20 to 40 3/8 Lubricator with drain cock ACG20 to 40 1/2 Nylon bowl ACG30, 40 Metal bowl with level gauge ACG20 With bowl guard Model combination ACG20 to 40 (9) Filter case with drain
2) Not conforming to ISO1179-1. 24 V 2 4 to 20 mA 120 3 0 to 20 mA 5 1 to 5 V 67 k 10 k 6 0 to 10 V 12 V 7 4 to 20 mA 120 8 0 to 20 mA Symbol Symbol B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) Body size Port size Rc Option Mounting Port 1(P), 2(A) Port 3(R) Applicable pilot valve (4) 00 M5 00 M5 01 00 01 02 00 02 03 04 M5 01 02 02 03 04 04 06 10 10 12 14 20 Without sub-plate M5
Flow direction Right Down With element service indicator AMP220 Rc NPT AMP320 AMP420 G 2 Exhaust Cleaner for Clean Rooms Series AMP How to Order AMP 2 0 2 03 Optional specifications Body size None Flow direction RightDown With element service indicator Nil R T 2 3 4 1/4 standard 3/8 standard 1/2 standard Element construction Accessories (optional) Nil None 2 2 stage B With bracket
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 04 (0.5 to 4 L/min), Supply/Return Port Size: 03 (3/8)
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 04 (0.5 to 4 L/min), Supply/Return Port Size: 03 (3/8)
PVPD 00 1 2 PVPD 03 0.3 0.35MPa 0.4MPa PVPD 04 0.4 0.35MPa 0.45MPa 3 05 0.5 0.35MPa 2) PV 06 0.6 0.5MPa 1) PD 3 0 1 PVPD PVPD PVPD PVPD K1 N.C. N.C. 2 J1 N.C. M5 Q1 +COM N.C.
AC200V 200V VK300-82-2-02 AC220V 220V VK300-82-2-04 ) AC240V 240V VK300-82-2-07 DC6V 6V VK300-82-4-51 () VEX1300-03 DC12V 12V VK300-82-4-06 G36-4-01 DC24V 24VD VK300-82-3-05 DC48V 48VD VK300-82-3-53 2 AC DC24V DC12V VEX1-11-2 DIN LED NL: LED (VEX110112011301 ) D R R R () (3.57) IP65() 7 VEX-OMV0001 VEX1 Series DIN (VEX110112011301 ) (VEX150117011901 ) 1) (G) DIN (D) () 2) 3
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Flow direction Right Down With element service indicator AMP220 Rc NPT AMP320 AMP420 G 2 Exhaust Cleaner for Clean Rooms Series AMP How to Order AMP 2 0 2 03 Optional specifications Body size None Flow direction RightDown With element service indicator Nil R T 2 3 4 1/4 standard 3/8 standard 1/2 standard Element construction Accessories (optional) Nil None 2 2 stage B With bracket
Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
CD1 CD2 CL CP 0.500 0 -.002 0.106 2.28 1.94 NCDP-150-SUS 0.750 0 -.002 0.140 3.10 2.72 NCDP-325-SUS Note: Cotter Pins are included. 7 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, Japan Phone: 03-5207-8271 Fax: 03-5298-5361 URL http://www.smcworld.com 10100 SMC Boulevard Noblesville, IN 46060, U.S.A.