Do not operate with the magnetic coupling out of position. If the magnetic coupling is out of position, push the external slider by hand (or the piston slider with air pressure) back to the proper position at the stroke end. 3. Do not apply a lateral load to the external slider.

90 MRHQ25S MRHQ25C 14 25 1560 180 Note) Values do not include auto switch weight.

Refer to the accessories on page 4-7-14. 4-7-9 10 Series VT317 Standard Specifications Type of actuation Direct operated type 2 position single solenoid Air Fluid Operating pressure range 0 to 0.9 MPa 10 to 50C (No freezing. Refer to page 4-18-4.)

Do NOT make upward piping. 2. Float type auto-drain (N.C.) DO NOT pipe upwards. (ANR)}. 2) Set pressure more than 0.1 MPa. 2. Float type auto-drain (N.C.) 1) Compressor can be used even if energy is under 3.7 kw. 2) Set pressure more than 0.15 MP 14-3-14

Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.

D DIN terminal DL DIN terminal with light DO DIN terminal (without connector, with gasket) Orifice diameter and Port Size Combinations T Conduit terminal Class Orifice diameter (mm) Port size 2 4 3 7 5 10 1/8 ( 6A) V V V V 2 1/4 ( 8A) V V V V 1/4 ( 8A) V V V V 3 3/8 (10A) V V V V V 1/2 (15A) V Connector 1/4 ( 8A) V V V V 3/8 (10A) V V V V V All class B coils come with surge

18.5 23.5 Proper mounting positions (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-F9 type D-F9 W type 2 6 5 8 12 11 In order that adjacent switches do not misoperate, they should be set within 1mm of the proper mounting positions indicated in the table above.

The motion of (15) the diaphragm acts on (10) the feedback spring through (8) the feedback lever, (14) the transmission lever and (9) the span adjustment lever to rest at the balance position generated by the input current. (2) The compensation spring is for direct feedback of the motion of (7) the exhaust valve to (4) the counter weight to increase the stability of the loop.

Do not operate a cylinder with its bumper bolt removed. If the bumper bolt is removed, the piston hits the head cover, causing damage to the cylinder. Therefore, do not use a cylinder without a bumper bolt. 2. The piston rod must be retracted when mounting the cylinder.

Do not warm the coil assembly with a heat insulator, etc. Use tape, heaters, etc., for freeze prevention on the piping and body only. They can cause the coil to burn out. Caution Direction of mounting 3. Avoid sources of vibration, or adjust the arm from the body to the minimum length so that resonance will not occur.

Place the O ring on the O ring mounting surface. 14 XM-OMP0002-A Step 5 O ring Bellows holder Wipe off any dust from the valve seal O-ring and the bellows holder surface.

Do not use compressed air contains chemicals, salinity, corrosive gas or synthetic oil with organic solvent. Using it may cause malfunction or damage of air gripper. Caution 1Mount air filter. Mount air filter near valve and before air gripper. Select filtration rating of 5m or less. 2Install after-cooler, air dryer and drain catch.

With floating joint 13 Internal Construction and Parts List A 14 Revision 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2011 SMC Corporation All Rights Reserved

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6

Orifice and Port Size Combinations Orifice size (mm) Class Port size Note) T Conduit terminal TL Conduit terminal with indicator light 2 3 4 5 7 10 D DIN terminal DL DIN terminal with indicator light DO DIN terminal (without connector) 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 (8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Connector Note) 10 is available only for N.C.

Installation location Do not install this product in an area that is exposed to rainwater or direct sunlight. Do not install in locations influenced by vibrations. If it must be used in such an area due to unavoidable circumstances, please contact SMC beforehand. 1016 Booster Regulator VBA Series Handling Caution 3.

When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc. When washing the element, do not wipe it using a stiff brush or rag. Refer to page 529 for Microswitch for differential pressure indication switch. r Removing the element Rotate the air breather (cap) one-third of a turn counterclockwise and remove it.