SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S32-13-M5"

No.PS-OMT0006-C PRODUCT NAME Pressure Sensor for General Fluids MODEL / Series / Product Number PSE575/576/577 Table of Contents Safety Instructions 2 Model Identification and How to Order 8 Names of Parts of Product and Handling Precautions 9 Mounting and Installation 10 Wiring 10 Troubleshooting 12 Specification 13 Specifications 13 Dimensions 15 -1No.PS-OMT0006-C Safety Instructions These

AS1200-M5 AS1000 AS1001F 5. M2.5X4L 56mm 0.050.15Nm 10 6. MHY2-10D 4 MHY2-16D 3 MHY2-20D 2 MHY2-25D 2 (ON) (OFF) 7.

Caution (1)For M3, M5, 10-32UNF Tightening method (10)Do not apply excessive force or shock to For M3 First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a hexagon wrench. Refer to Table below for reference. the body or fittings with an impact tool.

Buzzing Abrasion armature (AC coil Fall of power supply voltage 13 No.VF1000-OMN0002-A Remedy No. Remedy Regulate voltage, so that the voltage at the time of the operation becomes specifications range. Re-wire positively. Replace part. Replace part or re-wire positively. Replace valve.

Recommended torque unitNm Screw M5 1/8 1/4 3/8 1/2 3/4 1 Torque *1 79 1214 2224 2830 2830 3638 *1: First, tighten it by hand , then give it an additional 1/6 turn with a wrench. Do not apply any torsional moment, or bending moment except the weight of the air filter itself. External piping needs to be supported separately.

M5 types After tightening the fitting by hand, use a wrench to tighten the Please consult with SMC, as there are some standard valve products that use fluorine grease for food processing equipment (NSF H-1). fitting an additional approximately 1/6 to 1/4 turn.

(Refer to Section 6 Parts Replacement Procedure (pages 11 to 13) for details.) 5 XM-OMP0001-A 2. Product Specific Precautions 2 Common Specific Precautions 2 Be sure to read before handling Maintenance Parts Caution Only SMC specified parts should be used. Please refer to operation manual. The bonnet assembly should also be replaced when changing the seal material.

If a greater rotational torque is applied, the nonrotating rod (page 415) bends, exceeding the value of the non-rotating accuracy. 100 13 17 22 30 410 Guide Table Series MGF Operating Conditions Allowable eccentric load Allowable horizontal load The maximum value of load which can be applied at an eccentric position at a distance of l (mm) from the cylinder center. l l m m0 (Load center of

Dimensions 111 S: Vacuum pressure switch trimmer Pilot valve for air supply T: Release period adjustment trimmer Pilot valve for vacuum release M5 x 0.8 through (PE port) Release flow adjustment screw 3-Rc 1/8 SUP 112 97.5 97.5 85.5 26 30 VAC 62 10 20 8 30 2-4.5 Mounting hole 15.5 103 13 VAC Specific Product Precautions Be sure to read before handling.

Therefore, supply pressure passes through the air supply solenoid valve (1) and is applied to the pilot chamber (3). fne pressure in the pilot chamber 13) increases and operates on the upper surface of the diaphragm (4). As a result, the air supply valve (5) linked to the diaphragm (4) opens, and a portion of the supply pressure becomes output pressure.

Made to Order Body size 100 200 205 300 400 M3, M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Grease-free (Sealant: Fluoro coated) + Restrictor (Without Check Valve) -X21 Inch size 01 03 07 09 11 13 Metric size 02 23 04 06 08 10 12 Lock nut option 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" 2 3.2 Ex.)

x 0.8 20 0.1 10 30 R 1/8 1.5 Width across flats 12 Digital Pressure Switch ZSE30A Assembly 13 P601010 q w e Included Parts No. 1 2 3 Description Digital pressure switch Gauge nut O-ring Symbol 1 2 3 4 Digital pressure switch part no.

VNA Cylinder speed (mm/s) VNB Conditions Cylinder Supply pressure 0.49 MPa Stop valve SGC Cylinder Hydraulic fluid ISO VG32 VNC Load No load Piping length Piping length 1 m Speed controller Skip valve VNH VNA111A, CCVSO2 3/8B (9 mm) Bore size (mm) Piping diameter VNA211A, CCVLO2 VND 1/2B (13 mm) This series can supplement the capacity of conventional air-hydro valve units.

Related Equipment Pmax Vacuum pressure P1 Qmax Q1 Suction flow rate 1071 Series ZL112 Construction 1 11 5 9 Without valve 8 2 3 10 7 4 6 With valve 14 15 16 13 12 Description Part no. Part no. Note Comonent Parts Replacement Parts Description Material No. No.

M5 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/6 to 1/4 turn. As a reference value, tightening torque is 1 to 1.5 Nm. Note) If tightened excessively, the thread of the product may break or the gasket may deform. If tightened insufficiently, the thread of the product may become loose.

No.VFR5000-OMN0001 VFR5000 / -2,3 -4,5 -4,5 -5 -5 -6 -6 -6 -6 -7 -8,9,10,11 -12 -13 -1VFR5000-OMN0001 ISO/IEC) (JIS) 1) 2 *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating

Buzzing Abrasion armature (AC coil Fall of power supply voltage 13 No.VP300-OMM0002-A Remedy No. Remedy Regulate voltage, so that the voltage at the time of the operation becomes specifications range. Re-wire positively. Replace part. Replace part or re-wire positively. Replace valve.

-2VEX-OMV0001 / *3) 1 1.5 *3)1 1 () [] -3VEX-OMV0001 VEX1 Series / / C-R ( )C-R SDS DC VEX1101, VEX1201, VEX1301 2% () VEX1501, VEX1701, VEX1901 3% AC VEX1101, VEX1201, VEX1301 20% VEX1501, VEX1701, VEX1901 15% (SSR)AC 1) (C-R ) OFF () 2)() P2 N.O.() ZNR 1V 0C () 4 VEX-OMV0001 VEX1 Series / () DC 1(P)2(A) 1 ()ISO VG32 1) 2 ( )ISO VG32 (SDS) M5 1/61/4 11.5Nm ) 2)R,

(N) EPDM seal Bore size (mm) Rod size (mm) Piston area (mm2) Operating direction Operating pressure (MPa) For clean room specifications, refer to Pneumatic Clean Series catalog. 0.7 0.6 0.5 0.4 0.3 0.2 40 34 29 23 17 11 OUT IN 57 6 3 29 25 21 17 13 8 42 Standard Stroke 71 61 51 40 30 20 OUT IN 101 8 4 53 45 38 30 23 15 75 Model Standard stroke (mm) 158 136 113 90 68 45 OUT IN 226 12 6 10,