Appearance Terminal block For wiring, please refer to P.2-5 10,11Remote control 12,13Operation 14,15Failure L1,L2,L3: Power supply PE: Ground 15 14 13 12 11 10 PE L3 L2 L1 Customer Connection Side Customer Connection Side Terminal connecting screw: M3 Terminal connecting screw: M5 Crimped terminal width: 6.5mm or less Crimped terminal width: 13mm or less Applicable electric wire: 8mm 2
IDX-OM-W037-D PRODUCT NAME Thermo-dryer MODEL Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 This manual is intended to explain the installation and operation of the product. Only people who understand the basic operation of the product, or have basic knowledge and ability to handle industrial machinery, are allowed to work on the product.
Refer to the table for each pressure specification (page 80) Display/set pressure range Display/min. setting unit Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max. Electric spec.
IRV10 P P P P IRV20 P P P P P P 6 8 10 1/4" 5/16" 3/8" Metric Note 1) Accessories are shipped together. Inch Bottom bracket Single sided connections IRV 20 A C08 Made to Order For details, refer to page 10.
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% PS port 2(B) Vacuum pad port Flow Characteristics Response Time Flow Characteristics (When restrictor is fully open) 2(B)3/5(E) 1(P)2(B) b 0.19 Cv 0.05 C [dm3/(sbar)] 0.40 b 0.18 Cv 0.10 C [dm3/(sbar)] 0.24 Valve model Fluid passage 2(B) Port size M5 Valve model Response time ms (at 0.5 MPa) SJ3A6-ll-l
(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Accessories Hexagon socket head cap screw (M3 x 30): 2 pcs. Connects the SI unit and the valve manifold. Seal cap: 1 pc.
AS321FE AS331FE AS421FE AS431FE Model 8 10 6 8 10 12 12 10 6 8 10 Tubing O.D.
/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2 x 3 x 60 = 2736g/h. 6 7 8 3 1 2 3 4 5 Dew Point Conversion Chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric
dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62C. ( ) If this is cooled to 25C, the amount of condensed water generated will be 15.2g/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2
(mg/m3) 0.1 d 0.5 0.5 d 1.0 1.0 d 5.0 point() 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 Not specified 90,000 1,000 3 -20 3 1 4 Not specified Not specified 10,000 4 +3 4 5 5 Not specified Not specified 100,000 5 +7 6 +10 3.3.2 Air pressure 1) Operation with a pressure exceeding the maximum operating pressure leads to breakage of the product.
dew point) C -20 -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 [Example] If air at 30C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62C. ( ) If this is cooled to 25C, the amount of condensed water generated will be 15.2g/m3. ( ) Therefore, with an air flow rate of 3m3/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2
Metric size Inch size Stations Symbol Elbow Straight Elbow Note) OUT side Mounting position IN side Straight 6 8 10 8 6 10 4 6 4 6 Elbow Straight Elbow Note) OUT side Mounting position IN side Straight 1 2 3 4 5 6 7 8 9 M 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations Fitting type Symbol Fitting type Symbol 1/4 5/16 3/8 5/16 1
Stations Fitting Barb fitting One-touch fitting PV060-10-8A PV060-10-7A PV060-10-10A PV060-10-9A 4 stations Connector cable length 8 stations Nil 6 10 300 mm Barb fitting is included. One-touch fitting is mounted on the plate. 600 mm Note 1000 mm Insertion error checking ridge If only the fitting is needed, order with one of the part numbers below. e Fitting Part No.
to 1000 L/min 20 to 2000 L/min Instantaneous flow 5 to 525 L/min 10 to 1050 L/min 20 to 2100 L/min Set flow rate range Accumulated flow 0 to 999,999,990 L Instantaneous flow 1 L/min Flow Minimum setting unit Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse 10 L/pulse Accumulated value hold 1 Every 2 minutes or every 5 minutes Rated pressure range 0 to
102.5 5 14 20 32 10 6 14 22 124 92 114 40 14 7 20 28 134.5 96.5 124.5 50 146 102 14 132 8 20 30 63 CU Bore size (mm) L B + Full stroke RR CW CX+0.2 +0.4 CX CZ RR CL + Full stroke CZ -0.3 -0.1 18 36 10 32 A + Full stroke 18 36 10 40 22 44 14 50 22 44 14 63 10 Series RZQ Auto Switches Proper Mounting Position(For Detection of Piston A Stop Position) and Mounting Height D-A7 D-A80 =U B + First-stage
Extension locking Retraction locking 100 100 63 63 50 50 40 Load mass kg Load mass kg 40 10 10 32 32 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 1 1 100 500 100 500 Maximum speed mm/s Maximum speed mm/s Allowable load mass (Graph (2)) Horizontal (With and without switch) 10 Load mass m (kg) 1 63 50 40 32 m 0.1 10 100 Eccentric distance + Stroke L (mm) l S l: Eccentric distance (mm) S: Stroke (mm) L Cushion
Note 2 Note 1 M3 10: 2 pcs. ( Hexagon socket head cap screw ( with spring washer )) NOTE Holding with hand so that there will be no gap between SI unit and Air supply/exhaust block assembly, tighten the bolts.
A quick recovery time indicates little liquid pool. 50 Ratio of resistance [k m] Particle ratio [number/cc] PFMC 100 2 or 3 particles/cc PFMV 10 00 10 20 30 40 50 60 70 PF2A 1 0 5 10 15 20 25 30 Duration of flow [min] Duration of flow [hour] PF3W The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room
Internal data error. 16-3-10 10 Series PSE530/200 Multi-channel Controller/Pressure Sensor Operation 1: Initial Setting 1 Channel selection MPa kPa OUT1 OUT2 CH 1 2 3 4 CH2 CH3 CH4 CH1 PRESSURE ZSE ISE SET PSE SET button and hold for 2 seconds or longer.
Flow Rate and Sonic conductance AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 0.28 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 8 1/4" 5/16" 460 1.3 6 10, 12 8 6 6 10 2 Flow Direction Symbol on Body Tube O.D.