IC circuit Reed switch Solid state switch A96 A96V 5 V Grommet Yes Relay, PLC A93 A93V 12 V 2-wire 24 V 100 V 3-wire (NPN) M9N M9NV 5 V, 12 V IC circuit 3-wire (PNP) M9P M9PV 2-wire M9B M9BV 12 V Relay, PLC 3-wire (NPN) F9NW F9NWV 5 V, 12 V 24 V IC circuit Grommet Yes Diagnostic indication (2-color) 3-wire (PNP) F9PW F9PWV F9BW F9BWV 12 V 2-wire Water resistant (2-color) F9BA Although it
Symbol M12 connector pin number Wiring specication G1/2 terminal number Wiring specication r w (32) (12) (11) q 12 11 (12) e w w (31) e (31) (11) r q 32 31 q e (32) r VP542(R)/742(R)-X536 Internal pilot External pilot External pilot/With check valve r (32) w (12) r (32) w (12) r (32) w (12) 2(A) 2(A) 2(A) (31) e (11) q (31) e (11) q (31) e (11) q 3(R) 1(P) 3(R) 1(P) 3(R) 1(P) Safety limit
(mm) Applicable tubing KSH04-M5 KSH04-M6 KSH04-01S KSH06-M5 KSH06-M6 KSH06-01S KSH06-02S KSH08-01S KSH08-02S KSH08-03S KSH10-02S KSH10-03S KSH10-04S KSH12-03S KSH12-04S M5 x 0.8 M6 x 1 36.5 9 12 37 33 8 10.4 16 2.5 4.0 4.0 4 38 37.5 38 39.5 42.5 44 47 48 54 55 57.5 57 60 14 34 33.5 34 35.5 36.5 40 41 41.5 48 48.5 49.5 50.5 52 1 8 M5 x 0.8 M6 x 1 12 2.5 3 4.0 4.0 5.6 5.6 12 8 6 12.8 14 17
M12 connector pin number G1/2 terminal number X X VP544(R)/744(R)-X538 Internal pilot External pilot External pilot/With check valve r (32) w (12) r (32) w (12) r (32) w (12) 2(A) 2(A) 2(A) (31) e (11) q (31) e (11) q (31) e (11) q 3(R) 3(R) 3(R) r (32) w (12) r (32) w (12) r (32) w (12) 3(R) (31) e (11) q 3(R) (31) e (11) q 3(R) (31) e (11) q 1(P) 1(P) 1(P) X X VP544(R)/744(R)-X555 Internal
42 41 42 41 19 19 19 19 27 47 47 47 47 57 36 66 84 75 84 75 75 Note) Use the average speed when calculating static moment.
Stainless steel 20 DIN terminal gasket CR 21 DIN connector 229 Series VCH40 Dimensions VCH41 (N.C.) 1 (56) 41 62 50 17 (44) G1/2 128.5 Applicable cable O.D. 6 to 12 111 1(IN) 2(OUT) 22 Hexagon width across flats 38 98 2 x G3/4 x 16.3 2 x G1 x 19.1 56 VCH42 (N.O.) 1 (56) 41 17 62 50 (44) G1/2 139 Applicable cable O.D. 6 to 12 121.5 1(IN) 2(OUT) 22 Hexagon width across flats 38 98 2 x G3/4
Confirm that this value is less than 1/20 of the effective torque. 20 x 9.8 x (m1 + m2) x H/1000 20 x 9.8 x (0.07 + 0.05) x 10/1000 = 0.24 Graph 3
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
Apply a tightening torque of 8 to 12 Nm.
Rc1/8 10 NPT1/8 12 12 12 G1/8 10 8 10 M50.8 12 10 12 11 - No.ZB-OM00301 V PV PD PD Assy PD PV PVPD OUT1 OUT1 ON OUT2 OUT2 ON LED ON/OFF UP ON/OFF DOWN S SET 12 - No.ZB-OM00301 () -550 0.0750.096Nm 10mm 1mm 13 - No.ZB-OM00301 1mm (11.8) KQ2L04-M5N 16 1 PV PD (11.8) KQ2H04-M5N KQ2L04-M5N KQ2W04-M5N ZB1-BK1-A M2x14 2 M22 KQ2L04-M5NKQ2H04-M5NKQ2W04-M5N 14 - No.ZB-OM00301
state switch Relay, PLC 24 V 12 V Grommet Yes Water resistant (2-color indication) IC circuit 5 V, 12 V 12 V Auto switches marked with a symbol are produced upon receipt of order.
KPa, kgf/cm2, bar, psi Temp. oC, oF 0 to 2100 L/min 0 to 1050 L/min Instantaneous flow 12 (Displays 0 when the value is below 20 L/min.) (Displays 0 when the value is below 10 L/min.)
(LEC) 13.1(LEC) (LEC) (LEC) () () DRIVE ON(1) OUT05DRIVE ON(1)OFF(0) DRIVE OFF(0) OUT05 IN05 INPON(1)BUSYOFF(0) OUT05OFF(0)DRIVE OUT05OFF RESETON No.0DRIVEOFF(0) 41 - 13.2 (LEC) PLC PLC (LEC) Devicenet (LEC) (LEC) 30ms (LEC)30ms TMIO(LEC) DeviceNet 30ms (LEC) 1) 4() 4X30ms120ms [IO] 2) 12() 12X30ms360ms [IO] 3) 8( 6) () 8X30ms6X30ms420ms [IO] DeviceNet TM(LEC)PLC 42 - 14./
Tighten others with 0.60.05Nm. -27- 12. Domensions 12-1.
(Position lock) Nabeya Bi-tech Kaisha (Clamp lock) Adjusting angle per 1 rotation of angle adjusting screw 5.7 4.8 MA12 x 26 PSL-K-12 CLH-12 x 18 MA14 x 28 PSL-K-14 CLH-14 x 23 Please consult with manufacturers concerning further information on specifications. Precautions Backlash The rotary motion part has a structure that does not generate backlash.
OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC FUNC FUNC U Blue DC () Blue DC () -E PNP (1 output) + Analog voltage output -F PNP (1 output) + Analog current output Brown DC (+) Brown DC (+) Black OUT1 Black OUT1 + + White OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC Load Load FUNC FUNC U Blue DC () Blue DC () The FUNC terminal is connected when using the copy function.
The SY is available in body ported or base mounted styles, and can be used individually or manifold mounted.Plug-in connector connecting base, Top ported, Options: external pilot, built-in silencer, Connector types: D-sub, Flat ribbon cable (26, 20 or 10 pins), PC wiring, One-touch fittings, MFLD ASSY, 12-STA (SY), VALVE, SS5Y3 MANIFOLD SY3000, 1J, SS5Y3 OTHER SIZE RATING, .95532
Tighten them with the hexagon socket head cap screw with washers 12 . 17 15 3 10 14 26 11 5 12 19 9 12 14 1 11 26 4 2 6 15 Cushion seal 4 Direction of the shaft(key) 38 - 7. Mount the pipe 21 to the sub-plate 18 19 and 30 and fix with hexagon socket head cap screws 22 31 to the body 1 . 8.
Valve model VCL2 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCL3 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCL4 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 Mounting screws (for mounting bracket) are included