With exhaust interference prevention valve Note 23, 25) W Exhaust interference prevention valve Note) Refer to page 31 when mounting single unit to DIN rail. 2
0.450.6 Nm M3 0.81.2 M4 1.42.5 13 No.VFS4000-OMY0001 11 1 2 3 14 No.VFS4000-OMY0001 EXH.
SI () SI SI SI () ()SI SI SI IP67 M12/M8 SI ( ) SI SI ()SI CE -6No.EX-OMP0004CN-I
SI SI PLC PLC SI IP -7No.EX-OMP0004CN-I
EX260-SMJ 1 1 M12 32 /PNP() 2 M12 32 /NPN() 3 M12 16 /PNP() 4 M12 16 /NPN() MJ CC-Link -8No.EX-OMP0004CN-I
200 0.1MPa 0.1MPa 0 0 20 20 40 40 60 60 Gripping point L mm Gripping point L mm 4 Series MHS2 2 Finger Air Gripper Dimensions (mm) 1in = 25.4mm MHS2-16D to 25D 2-3.4, counter bore dia. 6.5 Counter bore depth SC (mounting hole) WA, depth 1.5 AA RA 3 AB RA VA, depth VB B NA RB NB RB XA, depth XB O Q 2-M4 x 0.7, thread depth 8 (mounting threads) 20 20 (Open DO) (Closed DC) FX FY FZ CB 7 4-M3
Correct mounting Incorrect mounting Auto switch Auto switch mounting screw M3 x 0.5 x 14l Auto switch mounting band (with brackets) 1. Wrap the mounting band around the cylinder tube, and place it in the approximate auto switch mounting position. 2.
n 2 123 112.5 91.5 16 3 123 112.5 91.5 16 4 135.5 125 102 17 5 148 137.5 112.5 18 6 148 137.5 123 12.5 7 160.5 150 133.5 13.5 8 173 162.5 144 14.5 9 185.5 175 154.5 15.5 10 198 187.5 165 16.5 3 135.5 125 102 17 4 148 137.5 112.5 18 5 148 137.5 123 12.5 6 160.5 150 133.5 13.5 7 173 162.5 144 14.5 8 185.5 175 154.5 15.5 9 198 187.5 165 16.5 10 210.5 200 175.5 17.5 L1 L2 L3 L4 L1 L2 L3 L4 31
Step 7 Reassembly of bonnet assembly (No.2) 3 Bolt 1 2 4 Bonnet assembly Port 1(P) Bolt size, Tool, Tightening torque of bolt (Nm) valve Bolt size Hex Tightening torque size wrench XLFV-16 M3 3 0.7 -25 M5 4 1.5 -40 M6 5 2.5 -50 M8 6 6.1 Body -63 M10 8 15 -80 Turn ON the solenoid valve to supply air pressure of 0.4MPa (G) to the port 1(P).
Round head screw (M3 x 8) 4 pcs. r Seal Cap (10 pcs.) Enclosed parts Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 4 pcs. Be sure to mount a seal cap on any unused I/O connectors. Otherwise, the specified enclosure cannot be maintained.
Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89
How to change the positional relationship between the transfer and piping directions The positional relationship between the transfer and piping directions can be changed in 90 increments (or 180 increments in case of 20). 20 Loosen the fixing screw (M3) beside the rod cover and pull up the guide rod.
VSA4230-02 VSA4230-03 VSA4230-04 VSA4330-02 VSA4330-03 VSA4330-04 VSA4430-02 VSA4430-03 VSA4430-04 2 position single VA 3 8 1 8 Rc 0.75 1 8 Rc 1 8 Rc SA 2 position double 3 8 1 8 Rc 0.86 1 8 Rc VA 1 8 Rc 3 position closed center 3 8 1 8 Rc 0.90 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (
View A PFW31(-M) PFW3-B DIN rail type 8-M3 3 x 7.2 (= 21.6) 36 2-3.4 6.4 15 1 2 3 4 6.5 26 FLOW SWITCH SMC 35.5 30 56 (4.5) 44 UNIT RESET SET 5 6 7 8 29 38 15.2 26
AD Accessory (Option) GD Applicable model HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Screw flange (With companion flange) HAWF-141 HAWF-142 HAWF-200 HAWF-200 Auto drain AD402-04 AD600-06 AD600-10 Model Selection (Flow Capacity l/min (ANR)) JIS Symbol Model HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 50C 2000 6000 12000 12000 12000 18000 1000 70C 100C 180C Inlet air temperature
) (Example) To get pressure drop at 0.3 MPa of air pressure, 5 m3 /min (ANR) of air flow and model HAW75-20, use 0.0065 MPa at 0.7 MPa from the table and convert P1 to 0.3 MPa.
00 Straight type AKH 04 A 01 S Male connector type With seal (Standard) M5 and 10-32 UNF types are not required.
Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21
No. of connection tubes Plug Model Color of release button D Socket KDM10S-23 KDM10S-04 KDM10S-06 KDM10S-08 KDM20S-23 KDM20S-04 KDM20S-06 KDM20S-08 KDM10P-23 KDM10P-04 KDM10P-06 KDM10P-08 KDM20P-23 KDM20P-04 KDM20P-06 KDM20P-08 3.2 4 6 MS Irregular faces for engagement 10 Allen wrench (Nominal width across flats 4) T 8 3.2 Blue VMG 4 6 8 20 Clamp bolt Panel mounting 1.
No.IP8S-OM09 64 < (C70) Span adjustment*31> Adjust zero point / span. Unlike automatic calibration of (C30), PID constant automatic setting is not performed. PID set once remains valid. This function is used when only zero-span adjustment is necessary.
Note 1) l (Drill through) Cotter pin d D m Dd9 L H B C 3 x 18l 4 x 25l 4 x 35l M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 36 51 72 4 4.5 5 3 4 4 44 60 82 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 -0.040 -0.076 -0.050 -0.093 -0.065 -0.117 Note 1) A cotter
Attachment plug with lead wire Non Plug-in Type VZS2000 3-7-15 Stacking type (Individual connection to each valve) VZS3000 3-7-31 3-7-1 2 Series VZS2000/3000 Precautions Be sure to read before handling.