Operating pressure: 0.5 MPa Lateral load 100 100.0 Eccentric distance Stroke 80 63 50 Load mass (kg) 10.0 40 100 32 25 20 100 Plate allowable lateral load (N) 80 1.0 63 16 12 50 0.1 40 50 100 200 300 500 32 Maximum piston speed (mm/s) 10 20, 25 12, 16 0 10 20 30 40 50 60 70 80 90 100 110 120 Stroke + Eccentric distance (mm) 794 Compact Cylinder: Guide Rod Type Series CQM Construction 12 to
100 75 28 65 32 13 22 20 M12 x 1.75 26 26 29 M22 x 1.5 35 1/2 26 12 130 75 155 90 100 38 6.5 118 118 90 35.5 80 35 13 27 19 M12 x 1.75 27 26 34 M27 x 2 35 1/2 34 16 145 90 172 100 125 38 6.5 140 140 112 35.5 80 35 15 27 19 M14 x 2 27 30 34 M27 x 2 35 1/2 34 18 170 112 200 100 160 42 9 174 174 140 45 100 38 17 36 22 M16 x 2 28 34 38 M33 x 2 40 3/4 43 20 205 140 240 108 (mm) Bore size (mm)
kPa 0 100 kPa 500 kPa 1 MPa PSE540 0 1 MPa PSE541 101 kPa 0 PSE543 100 kPa 100 kPa Mass: 2.9 g Head size: 9.6 x 20.8 x 18 mm ZSE ISE ZSP 18 9.6 PS 20.8 ISA PSE In case of PSE54-M3 IS Application examples Application examples ISG Pads can be directly mounted.
V 2-wire No 100 V or less Solid state auto switches marked with are produced upon receipt of order.
Possible to use in vacuum to 100 kPa.
A to B C to D 4 L 0.50 to 4.00 0.35 to 5.50 125 to 1000 0 to 1375 16 L 2.0 to 16.0 1.7 to 22.0 125 to 1000 0 to 1375 L/min 40 L 5.0 to 40.0 3.5 to 55.0 125 to 1000 0 to 1375 100 L 10 to 100 7 to 140 100 to 1000 0 to 1400 250 L 50 to 250 20 to 350 200 to 1000 0 to 1400 PF3W7 4 L 0.13 to 1.06 0.09 to 1.54 125 to 1000 0 to 1372 16 L 0.53 to 4.23 0.45 to 5.81 125 to 1000 0 to 1374 G/min 40 L
28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.
28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.
Standard Strokes Standard strokes (mm) Bore size (mm) 20 32 40 50 63 80 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 JIS symbol 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Double acting/Double rod 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25,
1.3 to 10.6 0.9 to 14.5 125 to 1000 0 to 1372 100 L 2.6 to 26.4 1.9 to 37.0 100 to 1000 0 to 1400 250 L 13 to 66 5 to 92 200 to 1000 0 to 1400 Temperature value PD value Series Unit Flow Rated temperature Display/settable Rated temperature Display/settable range range range range range Min. to Max.
Series MLGPM Series MLGPL 63 40 to 63: Over 100 stroke 50 to 100 80, 100: Over 200 stroke Type F Type B (Extension locking) (Retraction locking) Section B-B Section B-B Section A-A *Above figure show the unlocked state.
0 50 100 150 200 250 Flow rate [L/min] Flow rate [L/min] Straight Piping Length and Accuracy (Reference Value) The smaller the piping size, the more the product is affected by the straight piping length.
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Standard type Nil PNote 1) Axial piping type Note 1) The combination of axial piping type and both ends adjusters or retraction end adjusteris not
OVERALL ACCURACY < +/3% FS BFSL including linearity, repeatability and hysteresis DIMENSIONS 2.875" x 2.125" x 3.5" (73 x 54 x 89 mm) WEIGHT 8 oz (227 g) DRIVE UNIT MOTOR TYPE 15 bi-polar stepping COIL RESISTANCE 36 Ohms/Phase RECOMMENDED CURRENT < 170 mA / coil for 100% duty cycle GEAR RATIO 20.83:1 TYPICAL STEP RATE 200 steps / sec SDR-800/SDR-900 SERIES REGULATORS REGULATOR TYPE Constant
Possible to use in vacuum to 100 kPa Tubing material Tubing O.D.
(mm ) . 100 125 150 I 50 75 100 125 150 75 ~ 50 I 75 50 100 125 150 107 40 70 B3 83 97 11 5 128 128 194 52 62 204 212 225 225 1 83 107 50 70 83 ! 97 115 128 I 128 52 62 204 19' 212 2.?
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil Standard P Note 1) Axial piping Note 1) The combination of axial piping and both ends adjusters or retraction end adjusters is not available.
0 25 50 75 1.0 0 2 6 4 8 1.0 100 0 25 50 75 10 Input signal (%F.S.)
kPa (Detection distance 0.01 to 0.25 mm) 50 to 200 kPa (Detection distance 0.03 to 0.50 mm) Set pressure range 0 to 98 kPa 0 to 0.98 MPa 0 to 101 kPa 100 to 100 kPa 10 to 101.3 kPa 0.1 to 1 MPa 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa 0.1 to 0.45 MPa 0.1 to 0.4 MPa 20 to 101 kPa 101 to 101 kPa 0.1 to 1 MPa 0.4 to 10 MPa 0.5 to 15 MPa 100 to 100 kPa 0.1 to 1 MPa 0 to 1 MPa Voltage 12 to 24 VDC