PV SV 5.18 Communication function HRS Series 5-64 HRX-OM-R016 Chapter 5 Display and setting of various functions 46. Select contact input signal 1 function from the table below with [] key or [] key, and confirm by pressing SEL.
PV SV 5.19 Communication function HRS Series 5-64 HRX-OM-O021 Chapter 5 Display and setting of various functions 46. Select contact input signal 1 function from the table below with [] key or [] key, and confirm by pressing SEL.
PV SV 5.19 Communication function HRS Series 5-64 HRX-OM-R005 Chapter 5 Display and setting of various functions 46. Select contact input signal 1 function from the table below with [] key or [] key, and confirm by pressing SEL.
Status (6): Alarm will be generated after 600 seconds that is set for "AS.23: Range over detection timer" after the circulating fluid temperature exceeds the threshold of "AS.04". 5.20 Alarm customizing function HRS Series 5-64 HRX-OM-S004 Chapter 5 Display and setting of various functions Setting/Checking: Operation when compressor related alarms are generated 36.
Monitoring start When the circulating fluid temperature enters the alarm threshold range before it reaches the set time, the alarm monitoring will be started at that time. timer Settings of this function and example of alarm generating timing for 5.21.3 "Setting of temperature alarm monitoring method and generation timing". 5.22 Alarm Customizing Function HRSH Series 5-64 HRX-OM-Q026 Chapter
2.3) 1.9/ 2.1 (2.9/ 2.5) (For option T1) 2.1/ 2.3 (3.1/ 2.7) (For option T2) kW (50/60Hz) 17 Communication function Contact input / output, Serial RS-485 / RS-232C Noise level (50/60Hz) 18 dB(A) 63/ 67 70/ 70 Dimensions 19 mm W483xD550xH532 W483xD550xH710 Accessory20 Power supply connector,Maintenance handle for particle filter10, Operation manual,Particle filter element10 Weight 21 kg 64
XYC Exterior dimensions D G C C B J Fd (K Flange) 45 H Fn (KF Flange) A E Unit:mm Model A B C D E Fn Fd G H J XYC-25 100.2 85 48 1 23.5 40 26 64 28 XYC-40 130 115 66 2 38 55 41 84 36 C D G C B J Fd (K Flange) 45 K H Fn (KF Flange) A E Unit:mm Model A B C D E Fn Fd G H J K XYC-50 178 121 80 31 53 75 52 104 29 10.5 XYC-63 209 148 100 39 61 87 95 70 126 36 9 XYC-80 268 177 117 45.5 80 114 110
Operation continues when this alarm is generated. 5.20 Alarm Customizing Function HRS Series 5-64 HRX-OM-W032 Chapter 5 Display and Setting of Various Functions Setting/Checking: Operation setting when "Fan maintenance" alarm is generated 42. Press the [SEL] key once. Operation setting screen when "Fan maintenance" alarm is generated appears on the digital display. SV 43.
500 L Z73 B 25 25mm 32 32mm 40 40mm 2 s 1 n n () S () 2 s 1 B () L L (mm) (mm) 25 32 40 12000(1mm) 25 MY-A25L 25 MY-S25A MY-S25B 32 MY-A32L 32 MY-S25A MY-S25B 40 MY-A40L 40 MY-S32A MY-S32B 6-2 CEU2 NPN P PNP 24 6-3 CE1-R 05 5m 10 10m 15 15m 20 20m C A B CD E F G () 25 7-1 AA BB CC DD EE HA KA KB KK 9 45.5 5.5 M5x0.8 9.5 69 30.5 16 M6x1 11 54 6.5 M6x1 12 84 32 15 M8x1.25 14 64
Table 4 Recommended equipment Size Solenoid valve Speed controller Tube 10 VZ1000 seriesM5,Cv=0.05 VJ3000 seriesM5,Cv=0.2 AS1000 series(M5) 42.5 15 20 VZ3000 seriesRc1/8,Cv=0.2 VF1000 seriesRc1/8,Cv=0.15 AS2000 series(Rc1/8) 64 30 40 Solenoid valve is selected by elastic seal method -21- Mounting 4-1 Restriction of the load to axis Table of load below shows the allowable load when no moving
MHF2-8D MHF2-12D MHF2-16D MHF2-20D mm 8 12 16 20 MPa 0.150.7 0.10.7 oC -1060 mm 1) 0.05 120 c.p.m. 120 60 2) 1 N 19 48 90 141 8 12 16 20 () mm 16 24 32 40 32 48 64 80 65 155 350 645 85 190 445 850 3) g 120 275 650 1,225 1) 0.15mm 2) 0.5MPaL=20mm 3) 4 2 2-1 1. ( ) 2. 3. 4. 2-2. 1. 2. (1) (2) (3) 5 3. 4. 5. 6. (1) (2) ,2 , 7.
For example, keep 40 mm minimum distance from the cylinder with auto switch. 64 - Make sure to have intervals of 15 ms or longer (30 ms is recommended) between input signals and maintain the state of the signal for the same period because delay in PLC processing and electric actuator control part scan can occur. 4.4 Response time in receiving an electric actuator input signal Signal timing
LEC [] LEC ID 1 164 1) IO 1: 64 1 S 0 (+) 1000.00 (-) -1000.00 / 3000 3000 0.50 0.00 -9000.009000.00 2) LEY *16** 85 ~85 LEY *25** 65 ~65 LEY *32** 85 ~85 LEY *16*A* 95 ~95 LEY *25*A* 95 ~95 1+ /1+2 SW 2 /12 14 W 1 0.00 W 2 0.00 0.00 1 2P.33 2 CW + CCW + 1 CCW 2mm -32- 2 =02mm =0 aCCW 50mm 0 50mm CCW CW 0 10 20 30 40 50 [mm] 10 50mm CCW CW 10 20 30 40
Description of operation . 61 10.1 Return to origin . 61 10.2 Positioning Operation . 62 10.3 Pushing Operation . 64 10.4 Linear interpolation . 68 10.5 Circular interpolation . 71 10.6 Speed tuning control . 75 10.7 PLC output signal response time . 77 10.8 Methods of interrupting operation . 77 11.
EtherNet/IP . 43 8. . 44 8.1 . 44 (1) PLC (PLC) . 44 (2) PLC (PLC ) . 44 8.2 . 44 (1) PLC . 44 (2) PLC . 46 9. . 48 9.1 . 48 9.2 . 49 9.3 . 51 9.4 . 52 (1) ABS . 54 (2) INC . 54 (3) LIN-A / LIN-I . 54 (4) CIR-R / CIR-L . 55 (5) SYN-I . 55 10. . 56 10.1 . 56 -2No.JXC-OMT0001CN-C 10.2 . 57 10.3 . 60 10.4 . 64 10.5 . 67 10.6 . 71 10.7 PLC . 73 10.8 . 73 11. . 74 11.1 . 74 11.2
+917 ID1 ID3 RWwn+1826 ID1 ID4 RWwn+2735 ID1 ID5 RWwn+3644 ID1 ID6 RWwn+4553 ID1 ID7 RWwn+5462 ID1 ID8 RWwn+6371 ID1 ID9 RWwn+7280 ID1 ID10 RWwn+8189 ID1 ID11 RWwn+9098 ID1 ID12 RWwn+99107 ID1 1)12.1.1 2)0 12 38 - 12.1.1 8,16,32 8 8 ) RWwn+7 20mm/s100% 16 20mm/s 14h 10%100%1016 0Ah 0Ah 14h RWwn+7 15bi 8bit 7bit 0bit 16 16 (WORD) ) (RWwn+1)100mm/s 16 100mm/s 0064h 00 64
For IDH6/IDHA6 IDH6/IDHA6 For IDH6/IDHA6 DEVICE NAME CM Refrigerating Compressor Fan Motor for Condenser FM Overload Relay OLR Switch with Lamp ILS PTC Starter(Start Relay) PTC Magnetic Contactor MC THS Thermostat TB Terminal Block Temperature Controller TC Temperature Sensor TS Solid State Relay SSR Heater H Fuse F Ground Fault Circuit Interrupter GFCI Programable Logic Controller PLC 64
Figure 5-64 CH1(2) Analog Output Setting Screen 1, 2 [Tips] The setting has not taken effect while the box is flashing. 2. Touch the [Enter] key. The MESSAGE screen is displayed. Figure 5-65 CH1(2) Analog Output Setting Screen 1, 2 3. Touch the [YES] key. The setting takes effect.
communication error Output HOLD/CLEAR Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Insulation type Photo coupler insulation type Residual voltage 0.4 VDC or less Network communication specifications Item Specifications Applicable system CC-Link Ver.1.10 Occupied number of stations 1 station Allowable station number setting 1 to 64
4,5/32" 56 or more 44 or more 26 or more 20 or more 6 84 or more 66 or more 39 or more 30 or more 1/4" 89 or more 70 or more 57 or more 32 or more 8,5/16" 112 or more 88 or more 52 or more 40 or more 10 140 or more 110 or more 69 or more 50 or more 3/8" 134 or more 105 or more 69 or more 48 or more 12 168 or more 132 or more 88 or more 60 or more 1/2" 178 or more 140 or more 93 or more 64