Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, MINIATURE AIR, VACUUM, INSTRUMENTATION, PSE200/300/530-560, CB, PSE200/300/530-560 1/8 NPT, .17553 lb

2% F.S.or less, allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)20 mA or less (without load)IP65Operating: 0 to 50C, Stored: ?

Pressure sensor controller, Response time: 1 ms or less, Set pressure resolution: 1/1000, Repeatability: 0.1% F.S. or less, Enclosure: IP40, CONTROLLER, REMOTE DISPLAY, INSTRUMENTATION, PSE200/300/530-560, 1X, PSE200/300/530-560 OTHER SIZE, .37654 lb

0.1% F.S. or less, Enclosure: IP40, CONTROLLER, REMOTE DISPLAY, INSTRUMENTATION, PSE200/300/530-560, 1X, PSE200/300/530-560 OTHER SIZE, .40280 lb

Multi channel controller, Low power consumption: 55mA or less, NPN or PNP open collector available, Simplified application, Space saving, CONTROLLER, PRESSURE SENSOR, INSTRUMENTATION, PSE200/300/530-560, 1X, PSE200/300/530-560 OTHER SIZE, .36960 lb

Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, CQ2-Z, COMPACT CYLINDER, 493, 300 lb

Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable, Compact Cylinder, CQ2-Z, COMPACT CYLINDER, 493, 300 lb

. *3 Temperature characteristics (25 oC reference) 2%F.S. max. (15 to 35 oC) 5%F.S. max. (0 to 50 oC) Pressure characteristic (0 kPa reference 4) 2%F.S. max. (0 to 300 kPa) 5%F.S. max. (-70 to 0 kPa) Rated pressure range -70 kPa to 300 kPa Operating pressure range -100 kPa to 400 kPa Proof pressure 500 kPa (Non-linear output) 5 Output voltage 1 to 5 V Analogue output Response time 5 ms or

(page 72) Y S16 0x012C 3 R/W (300) P1H (Upper limit of the OUT1 window comparator) Setting of OUT1 upper limit of window comparator. (page 72) 0x04C4 (1220) 0x04C5 (1221) 0x04C6 (1222) 0x04C7 (1223) Y S16 0x0258 4 R/W (600) WH1 (Setting of OUT1 window comparator hysteresis) Setting of OUT1 window comparator hysteresis.

Max. 150 NL/min 3000 NL/min PF2A703H 5.5 CFM 106.0 CFM 300 NL/min 6000 NL/min PF2A706H 10.5 CFM 212.0 CFM 600 NL/min 12000 NL/min PF2A712H 21.0 CFM 423.5 CFM : Analogue output is based on the rated flow range at normal condition. Displayed flow range is based on standard condition. Therefore, the range of rated flow and the displayed flow are different..

Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 L/min L/min L/min L/min L/min Pressure Rated pressure range -50 kPa to 0.5 MPa -50 kPa to 0.75 MPa Proof pressure 1.0 MPa Output for PF2A3 Analogue voltage output (non-linear), Output impedance: 1 k Voltage output 1 to 5 V Output impedance 1 k Analogue output Current output 4 to 20 mA Load impedance Power supply voltage 12 V: 300

. -19No.PF-OMO0014-D Output for PF2W3 + Analogue (4 to 20 mA) type PF2W5--2Analogue output: 4 to 20 mA Load impedance: 300 (12 VDC) 600 (24 VDC) 1: Refer to the PF2W3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter. -20No.PF-OMO0014-D Troubleshooting Troubleshooting If an operation failure occurs with the product, use the chart

Min. load impedance: 100 k (Output impedance: 1 k) Analogue output Current output: 4 to 20 mA, Accuracy: 2%F.S. or less Max. load impedance: 300 or less with 12 VDC, 600 or less with 24 VDC Supply voltage 12 to 24 VDC 10% Power consumption (No load) 20 mA or less Enclosure IP65 Environment Operating temperature range Operation: 0 to 50 C, Storage: -25 to 85 C (no condensation or freezing

. -42No.PF-OMW0004-B Model PF3W704 PF3W720 PF3W740 Response time 6 0.5 s/1 s/2 s Analogue output Voltage output Output voltage: 1 to 5 V, Output impedance: 1 k Current output Output current: 4 to 20 mA Maximum load impedance: 300 for 12 VDC, 600 for 24 VDC Hysteresis Variable External input Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer 2-screen display

Designated nozzle: IBG1-12-10: Nozzle length (50, 100, 150, 300) Silencing nozzle: IBG1-12S Set including the designated nozzle and silencing nozzle: IBG1-12-10-S : Nozzle length (50, 100, 150, 300) 4. Impact resistance of the product is 150[m/s2]. Vibration resistance is 30[m/s2]. Avoid applying vibration exceeding the allowable value to the product. Mounting Warning 1.

3.3 Communication specification Table 3.3-1 Serial communication specification Item Specification Connector type (for the product) D-sub9P type Female connector Standard Select from EIA RS-485RS-232C Circuit type Half duplex Half duplex Transmission type Start-stop Protocol Modbus terminal1 Terminal resistance None :Default setting 1Refer to Modicon Co. protocol specifications "PI-MBUS-300

Current (% to the capacity of the main breaker of this product) Figure 3-6 Breaker operating characteristics curve HRZ Series 3.3 Procedure for Installation 3-9 3-9 HRX-OM-X010 Chapter 3 Transporting and Installation HRZ008-L-F HRZ008-L1-F 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX MAX 2min 1min Operating time 30s 20s 10s MIN 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300

Product Development Div. 6, Engineering Headquarters Japan Technical Center, SMC Corporation, Address: 4-2-2 Kinunodai, Tsukubamirai-city, Ibaraki-ken, 300-2493 TEL: +81 297-52-6 FAX: +81 297-20-5007 E-mail: kaihatsu_6_g3@.smcjpn.co.jp Note: The contents of this manual are subject to change without notice. i Warranty Scope of warranty and liability to the Thermo-con Please thoroughly understand

Faster Average speed [mm/s] Measuring conditions Supply pressure: 0.55 MPa 0 50 100 150 125-250 160-300 Bore size-Stroke 200-300 250-450 320-530 Speed adjustment rotary switch set value 0 5 9 Mounting: Vertical downward Load: no-load Operating direction: Upward *1 The average speed value is the stroke divided by the full stroke time.

Cylinder speed should be in the range of 50 mm/s to 300 mm/s. In addition, prevent knocking and bounding. Do not give torque to the piston rod. Is torque given to the piston rod?