SMC Corporation of America
Elite Part Number Search
Search Results "IS10L-30-N03-6PZ-D"

30 1A For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A SY100 30 A Lead wire length Without lead wire: (With connector and 2 pcs. of socket) Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm 4-3-7 8 Series SY100 Body Ported Grommet (G), (H): SY1 3 (A)-PM3(-F) 1 2 G H 21.3 9 4 1.7 6.6 21 16 10 2-1.8 (Mounting hole) 2-2.8 (Mounting hole) (Light

4.5 1.5 2 x Port size S U T (35.5) 42 H OUT IN 2 x M3 x 0.5 depth 5 L K N Symbol Model Port size A B D E F H K L N PFMC7501/7102 Rc1/2, NPT1/2 70 30 60.6 41.2 15 14 26 18 13.6 PFMC7202 Rc3/4, NPT3/4, G3/4 90 35 66.1 46.7 17.5 24 31 28 16.8 PFMC7501/7102 G1/2 76 30 60.6 41.2 15 14 26 18 13.6 Symbol Model Bracket dimensions S T U V W PFMC7501/7102 24 22 32 40 50 PFMC7202 30 30 42 48 58 Lead

IS Below set position OK ZSM PF2 W IF Data Energy consumption can be reduced compared with the conventional models (Conventional models: 50 kPa) 30 kPa Minimum operating pressure 30 kPa (ISA2-G) Position of supply port: Either right side or left side is available.

C2 LECSC2T S2 LECSS2T N2 LECSN2T 92 LECSN2T-9 E2 LECSN2T-E P2 LECSN2T-P -4- 1.1.2 Specification LESYH*(D,R,L)*S2/S3 Motor type S2/S3 Model LESYH16*S2 LESYH25R/LS3 LESYH25DS3 Parallel In-line Stroke[mm] 50,100 50,100,150 50,100,150 Horizontal 8 12 12 Max. work load [kg] Vertical 6 12 10 20 10 20 Force [N] (Set value: 15 to 30%) *1 65 to 131 127 to 255 79 to 157 154 to 308 98 to 197 192 to

30 50 60 30 30 50 60 Angle adjusting unit 30 47 90 150 30 47 90 150 1.1-4 Copper Free Precautions Size Rotation Vane style Port position 20 CRB1BW Be sure to read before handling.

4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).

JOG operation positioning operation programmed operation DO forced (Note 4) 0 0. b output single-step feed (Note 4) Test operation mode # #. d (Note 1) Motor-less operation # #.

Order it by indicating an option symbol for DIN rail mounting style, -D. In this case, a DIN rail which is approx. 30 mm longer than the manifold with the specified number of stations is attached. 5.5 1.25 L Dimension VQZ L = 12.5n + 10.5 35.5 1 23 No.

Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.

32 [mm] Bore size Arm opening angle A B C D E 25 90 148.4 69.4 72 30 30 105 152.5 73.5 32 90 157.7 73.6 71.5 40 35 105 3 Power Clamp Cylinder CKZT -X2797 -X2798 Dimensions: With Manually Operated Handle CKZT S-X2798 R L Refer to the CKZT S-X2797 (page 3) for dimensions other than those shown below. 47 42 20 (Black) 4 130 F . ax M 55 Handle position: Right Unclamping position Handle position

freezing) Bearing type Ball spline Rubber bumper Cushion Air cushion Effective cushion length (mm) 11 12 9 10 17 17 Lubrication Non-lube Reed switch: D-A9 Solid state switch: D-F9 D-F8 Reed switch: D-A9 Solid state switch: D-F9 Auto switches +1.0 0 Stroke tolerance mm 0.1 or less (within allowable torque values) 0.2 or less (within allowable torque values) Non-rotating accuracy Port size

D-F7BAL D-F79F D-F7LF D-F7NTL D-F79 D-F7P D-J79 D-F79W D-F7PW D-A72H D-A73H D-A76H D-A80H 32, 40 (mm) D-A72H D-A73H D-A76H D-F79W D-F7PW D-J79W D-F7NTL D-F7BAL D-F79F D-F7LF D-A80H D-F79 D-F7P D-J79 Auto switch model A B Hs A B Hs A B Hs A B Hs Symbol Standard stroke 32 40 9.5 13.5 6.5 9 32.5 36 9.5 13.5 10.5 13 32.5 36 14.5 18.5 10.5 13 32.5 36 6.5 9 32.5 36 13.5 17.5 Bore size (mm) Long

B 150 0400 A XC9 Bore size Auto switch Adjustment range A: 0 to 1" B: 0 to 2" Mounting Adjustable StrokeReturn Stroke Dimensions P + Stroke LF + Stroke (2) EE (NPTF) 4-DD D across flats AA D across flats 4-NT Depth ND d + Adjustable range SN + Stroke ZZ + Stroke + Adjustable range Bore size (in) MM KK A AA B C D DD E EA EE G J JA K R WF Y LF P ZZ TN XT SN d mm 150 (1.5") 5/8 7/16-20 3/4

CM2 CG1 MB How to Order MB1 NC D A1 B 150 0400 A XC8 CA2 Bore size Adjustment range A: 0 to 1" B: 0 to 2" Auto switch CS1 Mounting C76 Stroke Adjustable strokeExtend C85 C95 Dimensions CP95 P + Stroke d + Stroke + Adjustable range LD + Stroke NCM 4-DD D across flats 2-EE (NPTF) c + Adjustable range Stroke NCA AA D-X 20Depth ND 4-NT Data SN + Stroke ZZ + 2 stroke + Adjustable range (A: 1",

G D G 24V 0V Power supply{ 24V 0V D G D G 24V 0V 24V 0V Power supply{ 24V 0V Power supply{ G D 0V 24V G D 0V 24V G D 0V 24V G D 0V 24V Transmission line Transmission line Black White Brown Blue Crimped connector SL-J1A Main transmission line Transmission line 24V 0V Power supply{ 24V 0V Power supply{ 24V 0V D G D G 24V 0V 24V 0V D G D G 24V 0V 24V 0V Power supply{ 24V 0V Power supply{ Special

Proper auto switch mounting position A B Auto switch model D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 Cylinder model CYP15 93.5 24.5 CYP32 122 33 Auto Switch Mounting When mounting auto switches, they should be inserted into the cylinder's switch groove from the direction shown in the drawing on the right.